THE FUTURE SPACEBORNE HYPERSPECTRAL IMAGER ENMAP: ITS IN-FLIGHT RADIOMETRIC AND GEOMETRIC CALIBRATION CONCEPT

被引:0
|
作者
Schneider, M. [1 ]
Mueller, R. [1 ]
Krawzcyk, H. [2 ]
Bachmann, M. [1 ]
Storch, T. [1 ]
Mogulsky, V. [3 ]
Hofer, S. [3 ]
机构
[1] Deutsch Zentrum Luft & Raumfahrt DLR, Oberpfaffenhofen, Germany
[2] Deutsch Zentrum Luft & Raumfahrt DLR, D-12489 Berlin, Germany
[3] Kayser Threde GmbH, D-81379 Munich, Germany
来源
关键词
Geometric Calibration; Radiometric Calibration; Hyper spectral; Satellite;
D O I
暂无
中图分类号
P9 [自然地理学];
学科分类号
0705 ; 070501 ;
摘要
The German Aerospace Center DLR - namely the Earth Observation Center EOC and the German Space Operations Center GSOC - is responsible for the establishment of the ground segment of the future German hyperspectral satellite mission EnMAP (Environmental Mapping and Analysis Program). The Earth Observation Center has long lasting experiences with air- and spaceborne acquisition, processing, and analysis of hyperspectral image data. In the first part of this paper, an overview of the radiometric in-flight calibration concept including dark value measurements, deep space measurements, internal lamps measurements and sun measurements is presented. Complemented by pre-launch calibration and characterization these analyses will deliver a detailed and quantitative assessment of possible changes of spectral and radiometric characteristics of the hyperspectral instrument, e.g. due to degradation of single elements. A geometric accuracy of 100 m, which will be improved to 30 m with respect to a used reference image, if it exists, will be achieved by ground processing. Therfore, and for the required co-registration accuracy between SWIR and VNIR channels, additional to the radiometric calibration, also a geometric calibration is necessary. In the second part of this paper, the concept of the geometric calibration is presented in detail. The geometric processing of EnMAP scenes will be based on laboratory calibration results. During repeated passes over selected calibration areas images will be acquired. The update of geometric camera model parameters will be done by an adjustment using ground control points, which will be extracted by automatic image matching. In the adjustment, the improvements of the attitude angles (boresight angles), the improvements of the interior orientation (view vector) and the improvements of the position data are estimated. In this paper, the improvement of the boresight angles is presented in detail as an example. The other values and combinations follow the same rules. The geometric calibration will mainly be executed during the commissioning phase, later in the mission it is only executed if required, i.e. if the geometric accuracy of the produced images is close to or exceeds the requirements of 100 m or 30 m respectively, whereas the radiometric calibration will be executed periodically during the mission with a higher frequency during commissioning phase.
引用
下载
收藏
页码:267 / 272
页数:6
相关论文
共 50 条
  • [1] Calibration and Characterization of the EnMAP Hyperspectral Imager
    Baur, Simon
    Wachter, Richard
    Basili, Patrizia
    Lettner, Matthias
    Muecke, Martin
    Sornig, Manuela
    Fischer, Sebastian
    SENSORS, SYSTEMS, AND NEXTGENERATION SATELLITES XXIII, 2019, 11151
  • [2] PRE- AND IN-FLIGHT GEOMETRIC CHARACTERIZATION AND CALIBRATION CONCEPTS FOR THE ENMAP MISSION
    Storch, Tobias
    Lenfert, Kai
    Schneider, Mathias
    Mogulski, Valery
    Bachmann, Martin
    Sang, Bernhard
    Mueller, Rupert
    Hofer, Stefan
    Chlebek, Christian
    2012 IEEE INTERNATIONAL GEOSCIENCE AND REMOTE SENSING SYMPOSIUM (IGARSS), 2012, : 5021 - 5024
  • [3] In-Flight Absolute Radiometric Calibration of UAV Hyperspectral Camera and Its Validation Analysis
    Gou Zhi-yang
    Yan Lei
    Chen Wei
    Jing Xin
    Yin Zhong-yi
    Duan Yi-ni
    SPECTROSCOPY AND SPECTRAL ANALYSIS, 2012, 32 (02) : 430 - 434
  • [4] Characterization of Multiband Imager Aboard SELENEPre-flight and In-flight Radiometric Calibration
    Shinsuke Kodama
    Makiko Ohtake
    Yasuhiro Yokota
    Akira Iwasaki
    Junichi Haruyama
    Tsuneo Matsunaga
    Ryosuke Nakamura
    Hirohide Demura
    Naru Hirata
    Takamitsu Sugihara
    Yasuji Yamamoto
    Space Science Reviews, 2010, 154 : 79 - 102
  • [5] Characterization of Multiband Imager Aboard SELENE Pre-flight and In-flight Radiometric Calibration
    Kodama, Shinsuke
    Ohtake, Makiko
    Yokota, Yasuhiro
    Iwasaki, Akira
    Haruyama, Junichi
    Matsunaga, Tsuneo
    Nakamura, Ryosuke
    Demura, Hirohide
    Hirata, Naru
    Sugihara, Takamitsu
    Yamamoto, Yasuji
    SPACE SCIENCE REVIEWS, 2010, 154 (1-4) : 79 - 102
  • [6] In-flight spectral calibration of UAV hyperspectral imager based on radiance matching
    Yan Lei
    Gou Zhi-Yang
    Zhao Hong-Ying
    Chen Wei
    Yin Zhong-Yi
    Duan Yi-Ni
    JOURNAL OF INFRARED AND MILLIMETER WAVES, 2012, 31 (06) : 517 - 522
  • [7] Imager-to-radiometer in-flight cross calibration: RSP radiometric comparison with airborne and satellite sensors
    McCorkel, Joel
    Cairns, Brian
    Wasilewski, Andrzej
    ATMOSPHERIC MEASUREMENT TECHNIQUES, 2016, 9 (03) : 955 - 962
  • [8] IN-FLIGHT ABSOLUTE RADIOMETRIC CALIBRATION OF THE THEMATIC MAPPER
    CASTLE, KR
    HOLM, RG
    KASTNER, CJ
    PALMER, JM
    SLATER, PN
    DINGUIRARD, M
    EZRA, CE
    JACKSON, RD
    SAVAGE, RK
    IEEE TRANSACTIONS ON GEOSCIENCE AND REMOTE SENSING, 1984, 22 (03): : 251 - 255
  • [9] AN OVERVIEW OF ISS HISUI HYPERSPECTRAL IMAGER RADIOMETRIC CALIBRATION
    Obata, K.
    Tsuchida, S.
    Nagatani, I.
    Yamamoto, H.
    Kouyama, T.
    Yamada, Y.
    Yamaguchi, Y.
    Ishii, J.
    2016 IEEE INTERNATIONAL GEOSCIENCE AND REMOTE SENSING SYMPOSIUM (IGARSS), 2016, : 1924 - 1927
  • [10] Radiometric calibration of the in-flight blackbody calibration system of the GLORIA interferometer
    Monte, C.
    Gutschwager, B.
    Adibekyan, A.
    Kehrt, M.
    Ebersoldt, A.
    Olschewski, F.
    Hollandt, J.
    ATMOSPHERIC MEASUREMENT TECHNIQUES, 2014, 7 (01) : 13 - 27