Novel electrospun polyurethane grafts for vascular access in rats

被引:1
|
作者
Alqahtani, Saeed Saad [1 ,2 ]
Sloff, Marije [1 ,2 ,3 ]
Sawo, Pamir [1 ,2 ,3 ]
机构
[1] Maastricht Univ, Dept Vasc Surg, Med Ctr, NL-6200 MD Maastricht, Limburg, Netherlands
[2] Maastricht Univ, Dept Biomed Engn, Maastricht, Netherlands
[3] Maastricht Univ, CARIM Sch Cardiovasc Dis, Maastricht, Netherlands
来源
关键词
Arteriovenous fistula; polyurethane grafts; central venous catheter; neointimal hyperplasia; POLYTETRAFLUOROETHYLENE GRAFTS; MULTICENTER EVALUATION; EARLY EXPERIENCE; BYPASS GRAFTS; HEMODIALYSIS; SURVEILLANCE; HYPERPLASIA; ANASTOMOSIS; DISEASE;
D O I
10.1177/11297298221131393
中图分类号
R6 [外科学];
学科分类号
1002 ; 100210 ;
摘要
Objectives: The purpose of this study is to develop a new and improved polyurethane (PU) graft using electrospinning and chemical modifications for hemodialysis patients, which will replace the current standard, polytetrafluoroethylene (PTFE) graft. The chemical modifications aim to improve hemocompatibility and reduce thrombogenicity and neointimal hyperplasia. Method: The study population was randomized and divided equally into four groups; one control group received a PTFE graft, and three treatment groups received three different types of polyurethane grafts. Two duplex measurements were performed directly on the graft on the same locations, followed by a histologic examination. Results: In the first few days after the implantation animals lost some weight, it took a week to recover to pre-surgical weight. Throughout the 28 days, there was no significant difference between animals in wound, activity, and the general appearance. PTFE and PU A groups have lower compliance or reduced graft diameter due to neointimal hyperplasia development on Doppler interrogation. The histological analysis showed limited neointimal hyperplasia development and no excessive inflammatory response to any of the grafts. Conclusion: This study demonstrates that animals with polyurethane grafts show better blood flow because the developed NIH was inconspicuous, as indicated by the different velocity measure than controls on Duplex and minimal NIH development microscopically
引用
下载
收藏
页数:11
相关论文
共 50 条
  • [31] ARTERIOVENOUS GRAFTS FOR VASCULAR ACCESS IN HEMODIALYSIS
    KESTER, RC
    BRITISH JOURNAL OF SURGERY, 1979, 66 (01) : 23 - 28
  • [32] Biological vascular grafts for hemodialysis access
    Hossain, Mohammad A.
    Frampton, Adam E.
    Chowdhury, Tina T.
    Morsy, Mohamed
    EXPERT REVIEW OF MEDICAL DEVICES, 2013, 10 (02) : 171 - 175
  • [33] 100 POLYTETRAFLUROETHYLENE VASCULAR ACCESS GRAFTS
    ANDERSON, CB
    ETHEREDGE, EE
    SICARD, GA
    DIALYSIS & TRANSPLANTATION, 1980, 9 (03) : 237 - 238
  • [34] THE COMPLICATIONS OF ARTERIOVENOUS GRAFTS FOR VASCULAR ACCESS
    GUILLOU, PJ
    LEVESON, SH
    KESTER, RC
    BRITISH JOURNAL OF SURGERY, 1980, 67 (07) : 517 - 521
  • [35] CELLULARIZED ELECTROSPUN VASCULAR GRAFTS FOR RENAL ARTERY RECONSTRUCTION
    Ahn, Hyunhee
    Ju, Young Miin
    Kim, Cheil
    Jackson, John D.
    Yoo, James J.
    Lee, Sang Jin
    Atala, Anthony
    JOURNAL OF UROLOGY, 2014, 191 (04): : E826 - E826
  • [36] Innovations in vascular access prosthetic grafts
    Klee, U.
    Mistry, H.
    Brar, R.
    Valenti, D.
    GEFASSCHIRURGIE, 2012, 17 (02): : 106 - +
  • [37] Assessment of stenosis in vascular access grafts
    Van Tricht, I
    De Wachter, D
    Vanhercke, D
    Tordoir, J
    Verdonck, P
    ARTIFICIAL ORGANS, 2004, 28 (07) : 617 - 622
  • [38] Computational study on the haemodynamic and mechanical performance of electrospun polyurethane dialysis grafts
    Sjeng Quicken
    Yeshi de Bruin
    Barend Mees
    Jan Tordoir
    Tammo Delhaas
    Wouter Huberts
    Biomechanics and Modeling in Mechanobiology, 2020, 19 : 713 - 722
  • [39] Computational study on the haemodynamic and mechanical performance of electrospun polyurethane dialysis grafts
    Quicken, Sjeng
    de Bruin, Yeshi
    Mees, Barend
    Tordoir, Jan
    Delhaas, Tammo
    Huberts, Wouter
    BIOMECHANICS AND MODELING IN MECHANOBIOLOGY, 2020, 19 (02) : 713 - 722
  • [40] Patency rate and complications of polytetrafluoroethylene grafts compared with polyurethane grafts for hemodialysis access
    Ravari, Hassan
    Kazemzade, Gholam Hossein
    Modaghegh, Mohammad Hadi Saied
    Khashayar, Patricia
    UPSALA JOURNAL OF MEDICAL SCIENCES, 2010, 115 (04) : 245 - 248