Efficient on-line setup correction strategies using plan-intent functions

被引:13
|
作者
Keller, H [1 ]
Jaffray, DA [1 ]
Rosewall, T [1 ]
White, E [1 ]
机构
[1] Princess Margaret Hosp, Dept Radiat Phys, Toronto, ON M5G 2M9, Canada
基金
加拿大健康研究院;
关键词
treatment setup variations; on-line set-up correction strategies; action levels; workload;
D O I
10.1118/1.2192580
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
With the introduction of image-guided radiation therapy (IGRT) delivery systems on-line set-up correction strategies have gained in popularity. Usually, the correction workload of these strategies is high compared to off-line strategies as daily setup corrections have to be performed based on a predefined action level. In this work, it is proposed that on-line strategies must not only be judged in terms of workload but also in terms of efficacy. While workload can be easily predicted for such strategies, the efficacy must ultimately reflect the efficiency with which the original treatment plan intent is met. The purpose of this work is to investigate the tradeoff between workload and efficacy of three different on-line set-up correction strategies: The common fixed action level strategy and two novel on-line setup correction strategies, i.e., a dose-volume histogram (DVH) constraint and an equivalent uniform dose (EUD) score strategy that aim directly for better compliance with original treatment plan intent. All strategies were reformulated in terms of a score function that reflected treatment plan intent. A retrospective study was conducted on 5 prostate patients (7-field conformal, 79.8 Gy, 42 fractions). PTV margins were 10 mm except in the posterior direction (7 mm). The original treatment plan intent for these patients was defined using a set of DVH constraints. The results show that the on-line setup correction strategy based on a fixed action level of 3 mm resulted in a considerable correction workload. For larger action levels, a dose benefit (in terms of EUD) in the rectum and bladder was observed for all patients which is clinically "fortuitous" but difficult to take advantage of. In contrast, the application of the two novel strategies generally resulted in a controlled decrease of the dose to the rectum and the bladder with a smaller workload. It is concluded that using information about target anatomy and the planned dose distribution allows the design of specific correction strategies that are better tailored to the individual patient and that comply effectively with initial treatment plan intent. (c) 2006 American Association of Physicists in Medicine.
引用
收藏
页码:1388 / 1397
页数:10
相关论文
共 50 条
  • [1] Setup error in radiotherapy: On-line correction using electronic kilovoltage and megavoltage radiographs
    Pisani, L
    Lockman, D
    Jaffray, D
    Yan, D
    Martinez, A
    Wong, J
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2000, 47 (03): : 825 - 839
  • [2] On-line correction of setup errors with the novalis R system
    Linthout, N.
    RADIOTHERAPY AND ONCOLOGY, 2007, 84 : S10 - S11
  • [3] Strategies for using on-line practice problems
    Everett, Jessw.
    Mallouk, Kaitlin Engle
    Stanzione, Joseph Francis, III
    Morgan, Jenahvive K.
    2014 ASEE ANNUAL CONFERENCE, 2014,
  • [4] On-line interpolation using spline functions
    Lim, TJ
    Macleod, MD
    IEEE SIGNAL PROCESSING LETTERS, 1996, 3 (05) : 144 - 146
  • [5] OPTIMIZING SETUP MARGINS BY USING ON-LINE/OFF-LINE VERIFICATION PROTOCOLS
    Moura, F.
    RADIOTHERAPY AND ONCOLOGY, 2011, 99 : S235 - S235
  • [6] Electronic portal imaging with on-line correction of setup error in thoracic irradiation: Clinical evaluation
    Van de Steene, J
    Van den Heuvel, F
    Bel, A
    Verellen, D
    De Mey, J
    Noppen, M
    De Beukeleer, M
    Storme, G
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1998, 40 (04): : 967 - 976
  • [7] Efficient off-line feature selection strategies for on-line classifier systems
    Balya, D
    Timar, G
    Szatmari, I
    Rekeczky, C
    2004 IEEE INTERNATIONAL JOINT CONFERENCE ON NEURAL NETWORKS, VOLS 1-4, PROCEEDINGS, 2004, : 171 - 176
  • [8] Daily 3D on-line setup verification and correction for 45 prostate patients using implanted gold markers
    Pasma, K. L.
    Leijser, V.
    Schimmel, E.
    MEDICAL PHYSICS, 2006, 33 (06) : 2030 - 2030
  • [9] Locally efficient on-line strategies for routing packets along fixed paths
    Berenbrink, P
    Scheideler, C
    PROCEEDINGS OF THE TENTH ANNUAL ACM-SIAM SYMPOSIUM ON DISCRETE ALGORITHMS, 1999, : 112 - 121
  • [10] Efficient on-line data summarization using extremum summaries
    Girdhar, Yogesh
    Dudek, Gregory
    2012 IEEE INTERNATIONAL CONFERENCE ON ROBOTICS AND AUTOMATION (ICRA), 2012, : 3490 - 3496