Analysis of interelectrode short-circuit current in industrial copper electrorefining cells

被引:11
|
作者
Zeng, Qingyu [1 ]
Li, Chun [1 ]
Meng, Yi [1 ]
Tie, Jun [1 ]
Zhao, Rentao [1 ]
Zhang, Zhifang [1 ]
机构
[1] North China Univ Technol, Sch Mech & Mat Engn, Beijing 100144, Peoples R China
基金
中国国家自然科学基金;
关键词
Copper electrorefining; Interelectrode short-circuit; Optical fiber current sensor; Cathode current measurement; Rapid diagnostic method; NODULATION; ADDITIVES; ANODE;
D O I
10.1016/j.measurement.2020.108015
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
In the process of copper electrorefining, detecting and treating the interelectrode short-circuit faults is one of the main tasks in the workshop. In this paper, the cathode current in industrial copper electrorefining cells was measured by an optical fiber current sensor, and the current curves caused by interelectrode short-circuit have been obtained. The relationship between the characteristics of cathode current and the mechanism of interelectrode short-circuit is discussed. A rapid diagnostic method of short-circuit faults by monitoring the change of cathode current slope and standard deviation is proposed. The applicable scope of the method is also given. (C) 2020 The Authors. Published by Elsevier Ltd.