Unbalanced return air in commercial buildings

被引:0
|
作者
Withers, Charles R., Jr. [1 ]
机构
[1] Univ Cent Florida, Florida Solar Energy Ctr, Cocoa, FL 32922 USA
来源
ASHRAE Transactions 2006, Vol 112, Pt 1 | 2006年 / 112卷
关键词
D O I
暂无
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Research in 88 central Florida commercial buildings during the last decade has found that 26% of the air distribution systems had substantially unbalanced return air. Unbalanced return air occurs when there is a restriction to airflow between the supply discharge and the return air creating positive and negative pressure fields throughout the building. Severe consequences in commercial buildings can occur as a result of unbalanced airflows. This paper examines unbalanced return air and its consequences in three commercial buildings and explains why balancing airflow in buildings is a critical part of maintaining a healthy and energy-efficient building.
引用
收藏
页码:656 / 664
页数:9
相关论文
共 50 条
  • [21] An integrated model for the design of air-cooled chiller plants for commercial buildings
    Chan, Raymond K. L.
    Lee, Eric W. M.
    Yuen, Richard K. K.
    BUILDING AND ENVIRONMENT, 2011, 46 (01) : 196 - 209
  • [22] Time dynamics of electricity demand in air distribution systems for commercial buildings in Sweden
    Christiansson, L
    ENERGY, 1996, 21 (10) : 879 - 888
  • [23] Impact of outdoor air quality on the natural ventilation usage of commercial buildings in the US
    Chen, Jianli
    Brager, Gail S.
    Augenbroe, Godfried
    Song, Xinyi
    APPLIED ENERGY, 2019, 235 : 673 - 684
  • [24] Detailed measured air speed distribution in four commercial buildings with ceiling fans
    Luo, Maohui
    Zhang, Hui
    Raftery, Paul
    Zhou, Linxuan
    Parkinson, Thomas
    Arens, Edward
    He, Yingdong
    Present, Elaina
    BUILDING AND ENVIRONMENT, 2021, 200
  • [25] Critique of the design and operation of sustainable air-cooled chillers in commercial buildings
    Yu, F.W.
    Chan, K.T.
    Sit, R.K.Y.
    Yang, J.
    Energy Engineering: Journal of the Association of Energy Engineering, 2015, 112 (03): : 55 - 79
  • [26] A Wideband Unbalanced-To-Unbalanced Choke for Return Current Suppression in Antenna Measurements
    Yin, Xiaoyang
    Chen, Shengjian Jammy
    Zou, Longfang
    Fumeaux, Christophe
    2022 INTERNATIONAL SYMPOSIUM ON ANTENNAS AND PROPAGATION (ISAP), 2022, : 503 - 504
  • [27] NOTHING FOR COMMERCIAL BUILDINGS
    不详
    ECONOMIST, 1963, 207 (01): : 69 - 69
  • [28] Characterization of indoor and ambient air quality in modern commercial and recreational complex buildings in Hanoi
    Duong, Van Minh
    Hoang, Anh Le
    ATMOSPHERIC ENVIRONMENT, 2022, 291
  • [29] Energy audit and analysis of chilled water system for air conditioning of commercial buildings in Shanghai
    Wang, CQ
    Long, WD
    Ding, WT
    INTERNATIONAL SYMPOSIUM ON AIR CONDITIONING IN HIGH RISE BUILDINGS '2000, PROCEEDINGS, 2000, 2000 (03): : 123 - 127
  • [30] Sensitizing performance of air purifiers for the high-rise commercial buildings in urban core
    Budde, Sandeep
    Chani, Prabhjot Singh
    Agrawal, Sandeep
    FRONTIERS IN SUSTAINABLE CITIES, 2025, 6