Frequency Tuning Curves Derived from Auditory Steady State Evoked Potentials: A Proof-of-Concept Study

被引:6
|
作者
Markessis, Emily
Poncelet, Lue [1 ]
Colin, Cecile [2 ]
Coppens, Anglique [1 ]
Hoonhorst, Ingrid [2 ]
Kadhim, Hazim [3 ]
Deltenre, Paul [2 ,4 ]
机构
[1] Univ Libre Bruxelles, Fac Med, Dept Anat & Embryol, Brussels, Belgium
[2] Univ Libre Bruxelles, Fac Psychol Sci, Res Unit Cognit Neurosci, Brussels, Belgium
[3] Brugmann Univ Hosp, Dept Anatomopathol & Cytogenet, Brussels, Belgium
[4] Brugmann Univ Hosp, Clin Neurophysiol Lab, Brussels, Belgium
来源
EAR AND HEARING | 2009年 / 30卷 / 01期
关键词
MODULATION FOLLOWING RESPONSE; CHRONIC COCHLEAR PATHOLOGY; BRAIN-STEM RESPONSE; PURE-TONE MASKING; DEAD REGIONS; GUINEA-PIG; NERVE FIBERS; SINGLE-FIBER; HEARING-LOSS; STEREOCILIA DAMAGE;
D O I
10.1097/AUD.0b013e31818fbb7a
中图分类号
R36 [病理学]; R76 [耳鼻咽喉科学];
学科分类号
100104 ; 100213 ;
摘要
Objectives: Assess the feasibility of drawing tuning curves from the masking function of steady state potentials, Develop a noninvasive tool for research applications on cochlear frequency selectivity in sedated animals. Obtain pilot human data validating auditory steady state evoked potential-derived (ASSEP) tuning curves against psychophysical data. Design: ASSEP tuning curves were drawn in 10 Beagle puppies and six human adults using amplitude-modulated probes. Two probe frequencies (1 and 2 kHz) were used in dogs and only one (2 kHz) in humans. The modulation rates of the two probes were set to 81 and 88 Hz, respectively. Psychophysical tuning curves were obtained in 12 normal human subjects using the same maskers and either a pure-tone or an amplitude-modulated probe to verify if the latter had a specific effect on tuning curve parameters. Six of these 12 subjects participated in the electrophysiologic measurements. For each tuning curve, the intensity of the narrowband masker required just to mask the fixed probe was plotted for different masker center frequencies. Masker center frequencies extended to about half an octave above and an octave below the probe frequencies in 100-Hz steps. Tuning curve width (Q(10 dB) values), high- and low-frequency slopes (in dB/octave) and the masker frequency yielding the lowest masking threshold (maximal masker frequency) were computed. Canine Q(10 dB) values obtained were compared with those published for several species with other techniques. For humans, ASSEP and psychophysical tuning curves were directly compared in the same subjects and with published data. Results: In dogs, the ASSEP method yielded reproducible tuning curves with qualitative and quantitative parameters similar to other physiologic measures of tuning obtained in various animals. 010 dB values were greater at 2 than at 1 kHz, reflecting the well-known correlation between sharpness of tuning and central frequency. In humans, ASSEP 010 dB values were slightly smaller than the psychophysical ones, but were greater by a factor of 2 than those obtained with previously published electrophysiologic procedures. In both species, detuning-a shift of the tip of the curve away from the probe frequency-was frequently observed as upward shifts with a maximal value of 200 Hz. Human psychophysical tuning curves also showed a certain amount of upward detuning. The intraindividual comparison of the two types of probes performed on human subjects with the psychophysical method did not indicate a specific effect of the amplitude-modulated probe on the curve parameters. Neither did the intraindividual comparisons indicate that an amplitude-modulated probe per se promoted detuning. Detuning has been observed with several other techniques and is usually attributed to nonlinear interactions between masker and probe in simultaneous masking. Conclusions: The results demonstrate the feasibility of measuring realistic ASSEP tuning curves in sedated dogs and in sleeping human adults. The ASSEP tuning curves exhibit a series of classical features similar to those obtained with time-honored methods. These results pave the way for the development of a noninvasive electrophysiologic method for tuning curve recording and its applications in noncooperative experimental animals or clinical subjects.
引用
收藏
页码:43 / 53
页数:11
相关论文
共 50 条
  • [31] A study on dynamic model of steady-state visual evoked potentials
    Zhang, Shangen
    Han, Xu
    Chen, Xiaogang
    Wang, Yijun
    Gao, Shangkai
    Gao, Xiaorong
    JOURNAL OF NEURAL ENGINEERING, 2018, 15 (04)
  • [32] Bioremediation of hydrocarbons from contaminated wood: A proof-of-concept study
    Popova, IE
    Beklemishev, MK
    Kozliak, EI
    ENGINEERING IN LIFE SCIENCES, 2005, 5 (03): : 223 - 233
  • [33] The effect of motion frequency and sound source frequency on steady-state auditory motion evoked potential
    Zhang, Huanqing
    Xie, Jun
    Tao, Qing
    Xiao, Yi
    Cui, Guiling
    Fang, Wenhu
    Zhu, Xinyu
    Xu, Guanghua
    Li, Min
    Han, Chengcheng
    HEARING RESEARCH, 2023, 439
  • [34] Decoding Steady-State Visual Evoked Potentials From Electrocorticography
    Wittevrongel, Benjamin
    Khachatryan, Elvira
    Hnazaee, Mansoureh Fahimi
    Camarrone, Flavio
    Carrette, Evelien
    De Taeye, Leen
    Meurs, Alfred
    Boon, Paul
    Van Roost, Dirk
    Van Hulle, Marc M.
    FRONTIERS IN NEUROINFORMATICS, 2018, 12
  • [35] Hydrophobic Aerogels from Vinyl Polymers Derived from Radical Polymerization: Proof-of-Concept
    Adolfs, Claudia
    Altarabeen, Razan
    Kimmritz, Leon
    Gibowsky, Lara
    Schroeter, Baldur
    Beuermann, Sabine
    Smirnova, Irina
    MACROMOLECULAR RAPID COMMUNICATIONS, 2024, 45 (15)
  • [36] The effect of spatial frequency on chromatic and achromatic steady-state visual evoked potentials
    Arakawa, K
    Tobimatsu, S
    Tomoda, H
    Kira, J
    Kato, M
    CLINICAL NEUROPHYSIOLOGY, 1999, 110 (11) : 1959 - 1964
  • [37] Comparative Study of Frequency Recognition Techniques for Steady-State Visual Evoked Potentials According to the Frequency Harmonics and Stimulus Number
    Moghadam, Maedeh Azadi
    Maleki, Ali
    Journal of Biomedical Physics and Engineering, 2024, 14 (04): : 365 - 378
  • [38] Steady-state visual evoked potentials in the low frequency range in migraine: a study of habituation and variability phenomena
    de Tommaso, M
    Stramaglia, S
    Schoffelen, JM
    Guido, M
    Libro, G
    Losito, L
    Sciruicchio, V
    Sardaro, M
    Pellicoro, M
    Puca, FM
    INTERNATIONAL JOURNAL OF PSYCHOPHYSIOLOGY, 2003, 49 (02) : 165 - 174
  • [39] Computer-assisted therapy for medication-resistant auditory hallucinations: proof-of-concept study
    Leff, Julian
    Williams, Geoffrey
    Huckvale, Mark A.
    Arbuthnot, Maurice
    Leff, Alex P.
    BRITISH JOURNAL OF PSYCHIATRY, 2013, 202 (06) : 428 - 433
  • [40] Adapting Footfall Rhythmicity to Auditory Perturbations Affects Resilience of Locomotor Behavior: A Proof-of-Concept Study
    Ravi, Deepak K.
    Heimhofer, Caroline C.
    Taylor, William R.
    Singh, Navrag B.
    FRONTIERS IN NEUROSCIENCE, 2021, 15