Adiabatic RF pulse design for Bloch-Siegert B1+ mapping

被引:16
|
作者
Khalighi, Mohammad Mehdi [1 ]
Rutt, Brian K. [2 ]
Kerr, Adam B. [3 ]
机构
[1] GE Healthcare, Global Appl Sci Lab, Menlo Pk, CA USA
[2] Stanford Univ, Dept Radiol, Stanford, CA 94305 USA
[3] Stanford Univ, Dept Elect Engn, Magnet Resonance Syst Res Lab, Stanford, CA 94305 USA
关键词
B-1(+) mapping; flip angle; Bloch-Siegert shift; off resonance; parallel transmit; adiabatic RF pulse design; STEADY-STATE;
D O I
10.1002/mrm.24507
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The Bloch-Siegert (B-S) B1+ mapping method has been shown to be fast and accurate, yet it suffers from high Specific Absorption Rate (SAR) and moderately long echo time. An adiabatic RF pulse design is introduced here for optimizing the off-resonant B-S RF pulse to achieve more B-S B1+ measurement sensitivity for a given pulse width. The extra sensitivity can be used for higher angle-to-noise ratio B1+ maps or traded off for faster scans. Using numerical simulations and phantom experiments, it is shown that a numerically optimized 2-ms adiabatic B-S pulse is 2.5 times more efficient than a conventional 6-ms Fermi-shaped B-S pulse. The adiabatic B-S pulse performance is validated in a phantom, and in vivo brain B1+ mapping at 3T and 7T are shown. Magn Reson Med 70:829-835, 2013. (c) 2012 Wiley Periodicals, Inc.
引用
收藏
页码:829 / 835
页数:7
相关论文
共 50 条
  • [21] Highly-Accelerated Bloch-Siegert |B+1| Mapping Using Joint Autocalibrated Parallel Image Reconstruction
    Sharma, Anuj
    Tadanki, Sasidhar
    Jankiewicz, Marcin
    Grissom, William A.
    MAGNETIC RESONANCE IN MEDICINE, 2014, 71 (04) : 1470 - 1477
  • [22] Rapid B1+ Mapping Using a Preconditioning RF Pulse with TurboFLASH Readout
    Chung, Sohae
    Kim, Daniel
    Breton, Elodie
    Axel, Leon
    MAGNETIC RESONANCE IN MEDICINE, 2010, 64 (02) : 439 - 446
  • [23] Integrated Bloch-Siegert B1 mapping and multislice imaging of hyperpolarized 13C pyruvate and bicarbonate in the heart
    Lau, Angus Z.
    Chen, Albert P.
    Cunningham, Charles H.
    MAGNETIC RESONANCE IN MEDICINE, 2012, 67 (01) : 62 - 71
  • [24] Linear Bloch-Siegert phase-encoded low-field MRI: RF coils, pulse sequence, and image reconstruction
    Srinivas, Sai Abitha
    Martin, Jonathan B.
    Vaughn, Christopher E.
    Grissom, William A.
    NMR IN BIOMEDICINE, 2024, 37 (12)
  • [25] OPTIMIZED LINEAR COMBINATIONS OF CHANNELS FOR COMPLEX MULTIPLE-COIL B1 FIELD ESTIMATION WITH BLOCH-SIEGERT B1 MAPPING IN MRI
    Zhao, Feng
    Fessler, Jeffrey A.
    Wright, Steven M.
    Rispoli, Joseph V.
    Noll, Douglas C.
    2013 IEEE 10TH INTERNATIONAL SYMPOSIUM ON BIOMEDICAL IMAGING (ISBI), 2013, : 942 - 945
  • [26] Robust 3D Bloch-Siegert based B1+mapping using multi-echo general linear modeling
    Corbin, Nadege
    Acosta-Cabronero, Julio
    Malik, Shaihan J.
    Callaghan, Martina F.
    MAGNETIC RESONANCE IN MEDICINE, 2019, 82 (06) : 2003 - 2015
  • [27] Regularized Estimation of Magnitude and Phase of Multi-Coil B1 Field Via Bloch-Siegert B1 Mapping and Coil Combination Optimizations
    Zhao, Feng
    Fessler, Jeffrey A.
    Wright, Steven M.
    Noll, Douglas C.
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2014, 33 (10) : 2020 - 2030
  • [28] Using the heteronuclear Bloch-Siegert shift of protons for B1 calibration of insensitive nuclei not present in the sample
    Hung, Ivan
    Gor'kov, Peter
    Gan, Zhehong
    JOURNAL OF MAGNETIC RESONANCE, 2020, 310
  • [29] B1 inhomogeneity-corrected T1 mapping and quantitative magnetization transfer imaging via simultaneously estimating Bloch-Siegert shift and magnetization transfer effects
    Jang, Albert
    Han, Paul K.
    Ma, Chao
    El Fakhri, Georges
    Wang, Nian
    Samsonov, Alexey
    Liu, Fang
    MAGNETIC RESONANCE IN MEDICINE, 2023, 90 (05) : 1859 - 1873
  • [30] Accelerated B1+ mapping and robust parallel transmit pulse design for heart and prostate imaging at 7 T
    Egger, Nico
    Nagelstrasser, Sophia
    Wildenberg, Saskia
    Bitz, Andreas
    Ruck, Laurent
    Herrler, Juergen
    Meixner, Christian Rainer
    Kimmlingen, Ralph
    Lanz, Titus
    Schmitter, Sebastian
    Uder, Michael
    Nagel, Armin Michael
    MAGNETIC RESONANCE IN MEDICINE, 2024, 92 (05) : 1933 - 1951