Calculation of effective dose from measurements of secondary neutron spectra and scattered photon dose from dynamic MLC IMRT for 6 MV, 15 MV, and 18 MV beam energies

被引:122
|
作者
Howell, RM
Hertel, NE
Wang, ZL
Hutchinson, J
Fullerton, GD
机构
[1] Emory Univ, Sch Med, Dept Radiat Oncol, Atlanta, GA 30322 USA
[2] Georgia Inst Technol, Atlanta, GA 30332 USA
[3] Univ Texas, Hlth Sci Ctr, San Antonio, TX 78229 USA
关键词
secondary neutrons; IMRT; effective dose;
D O I
10.1118/1.2140119
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Effective doses were calculated from the delivery of 6 MV, 15 MV, and 18 MV conventional and intensity-modulated radiation therapy (IMRT) prostate treatment plans. ICRP-60 tissue weighting factors were used for the calculations. Photon doses were measured in phantom for all beam energies. Neutron spectra were measured for 15 MV and 18 MV and ICRP-74 quality conversion factors used to calculate ambient dose equivalents. The ambient dose equivalents were corrected for each tissue using neutron depth dose data from the literature. The depth corrected neutron doses were then used as a measure of the neutron component of the ICRP protection quantity, organ equivalent dose. IMRT resulted in an increased photon dose to many organs. However, the IMRT treatments resulted in an overall decrease in effective dose compared to conventional radiotherapy. This decrease correlates to the ability of an intensity-modulated field to minimize dose to critical normal structures in close proximity to the treatment volume. In a comparison of the three beam energies used for the IMRT treatments, 6 MV resulted in the lowest effective dose, while 18 MV resulted in the highest effective dose. This is attributed to the large neutron contribution for 18 MV compared to no neutron contribution for 6 MV. (c) 2006 American Association of Physicists in Medicine.
引用
收藏
页码:360 / 368
页数:9
相关论文
共 50 条
  • [31] Monte Carlo calculation of Photo-Neutron dose produced by circular cones at 18 MV photon beams
    Banaee, N.
    Nedaie, H. A.
    Hosseinzade, E.
    RADIOTHERAPY AND ONCOLOGY, 2018, 127 : S986 - S986
  • [32] MONTE CARLO SIMULATION OF 6, 10 AND 18 MV PHOTON BEAM DOSE DISTRIBUTION IN A BRAIN TUMOR
    Gonzales-Ccoscco, Alberto E.
    Guzman-Calcina, Carmen S.
    Vega-Ramirez, Jose L.
    MOMENTO-REVISTA DE FISICA, 2023, (67): : 22 - 38
  • [33] The trade-off between neutron dose and skin dose for 6MV versus 18MV for prostate IMRT: Does the 20cm rule still apply?
    Howell, R. M.
    Koontz-Raisig, W.
    Johnstone, P. A. S.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2006, 66 (03): : S678 - S678
  • [34] Equivalent square formula for determining the surface dose of rectangular field from 6 MV therapeutic photon beam
    Apipunyasopon, Lukkana
    Srisatit, Somyot
    Phaisangittisakul, Nakorn
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2013, 14 (05): : 196 - 204
  • [35] Scattered fractions of dose from 6, 10, 18, and 25 MV linear accelerator X rays in radiotherapy facilities
    Shobe, J
    Rodgers, JE
    Taylor, PL
    HEALTH PHYSICS, 1999, 76 (01): : 27 - 35
  • [36] Assessment of skyshine photon dose rates from 9 and 18 MV medical linear accelerators
    Rostampour, N.
    Jafari, S.
    Saeb, M.
    Keshtkar, M.
    Shokrani, P.
    Ahnasi, T.
    INTERNATIONAL JOURNAL OF RADIATION RESEARCH, 2018, 16 (04): : 499 - 503
  • [37] Measurements of dose for 6 and 18 MV photon spectra in a phantom and comparison to calculations of 3-D adjoint Monte Carlo code
    Yang, C
    Brucker, G
    Jordan, T
    MEDICAL PHYSICS, 2004, 31 (06) : 1901 - 1901
  • [38] Surface dose and build-up region measurements with wedge filters for 6 and 18 MV photon beams
    Bilge, Hatice
    Ozbek, Nurdan
    Okutan, Murat
    Cakir, Aydin
    Acar, Hilal
    JAPANESE JOURNAL OF RADIOLOGY, 2010, 28 (02): : 110 - 116
  • [39] A General Model for Stray Dose Calculation of Static and Intensity-Modulated Photon Radiation for 15 MV Beam Energy
    Hauri, P.
    Hasler, P.
    Schneider, U.
    MEDICAL PHYSICS, 2017, 44 (06) : 2999 - 2999
  • [40] Surface dose and build-up region measurements with wedge filters for 6 and 18 MV photon beams
    Hatice Bilge
    Nurdan Ozbek
    Murat Okutan
    Aydın Cakir
    Hilal Acar
    Japanese Journal of Radiology, 2010, 28 : 110 - 116