Longitudinal in vivo imaging of bone formation and resorption using fluorescence molecular tomography

被引:14
|
作者
Lambers, F. M. [1 ]
Stuker, F. [2 ]
Weigt, C. [1 ]
Kuhn, G. [1 ]
Koch, K. [1 ]
Schulte, F. A. [1 ]
Ripoll, J. [3 ]
Rudin, M. [2 ]
Mueller, R. [1 ]
机构
[1] Swiss Fed Inst Technol, Inst Biomech, CH-8093 Zurich, Switzerland
[2] Univ Zurich, Inst Biomed Engn, Zurich, Switzerland
[3] Fdn Res & Technol Hellas FORTH, Inst Elect Struct & Laser, Iraklion, Crete, Greece
关键词
Multimodality imaging; Fluorescence molecular tomography; In vivo micro-computed tomography; Dynamic bone morphometry; Bone; NONINVASIVE OPTICAL-DETECTION; FUNCTIONAL ADAPTATION; OSTEOGENIC RESPONSE; CANCELLOUS BONE; TAIL VERTEBRAE; CORTICAL BONE; NITRIC-OXIDE; REPRODUCIBILITY; VALIDATION; STIMULATION;
D O I
10.1016/j.bone.2012.11.001
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Bone research often focuses on anatomical imaging of the bone microstructure, but in order to gain better understanding in how bone remodeling is modulated through interventions also bone formation and resorption processes should be investigated. With this in mind, the purpose of this study was to establish a longitudinal in vivo imaging approach of bone formation and resorption using fluorescence molecular tomography (FMT). In this study the reproducibility, accuracy and sensitivity of FMT for bone imaging were assessed by performing longitudinal measurements with FMT and comparing it to in vivo micro-computed tomography on a set of control mice, and mice in which load-adaptation was induced in the sixth caudal vertebra. The precision error for FMT measurements, expressed as coefficient of variation, was smaller than 16%, indicating acceptable reproducibility. A correlation was found between bone resorption measured with FMT and bone resorption rate measured with in vivo micro-computed tomography only over the first 14 days (R = 0.81, p<0.01), but not between bone formation measured with FMT and bone formation rate measured with in vivo micro-CT. Bone formation measured by FMT was 89-109% greater (p<0.05) for mice subjected to mechanical loading than control mice. Bone resorption was 5-8% lower, but did not reach a significant difference between groups, indicating moderate sensitivity for FMT. In conclusion, in vivo FMT in mouse tail bones is feasible but needs to be optimized for monitoring load adaptation in living mice. (C) 2012 Elsevier Inc. All rights reserved.
引用
收藏
页码:587 / 595
页数:9
相关论文
共 50 条
  • [21] In-vivo lung cancer imaging in mice using 360° free-space fluorescence molecular tomography
    Deliolanis, Nikolaos
    Lasser, Tobias
    Niedre, Mark
    Soubret, Antoine
    Ntziachristos, Vasilis
    2006 28TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-15, 2006, : 2828 - +
  • [22] Noninvasive in vivo fluorescence molecular imaging
    Choi, Yongdoo
    TISSUE ENGINEERING AND REGENERATIVE MEDICINE, 2008, 5 (02) : 204 - 211
  • [23] Ex Vivo Fluorescence Molecular Tomography of the Spine
    Pimpalkhare, Monish
    Chen, Jin
    Venugopal, Vivek
    Intes, Xavier
    INTERNATIONAL JOURNAL OF BIOMEDICAL IMAGING, 2012, 2012
  • [24] Ex vivo fluorescence molecular tomography of the spine
    Pimpalkhare, Monish
    Chen, Jin
    Venugopal, Vivek
    Intes, Xavier
    International Journal of Biomedical Imaging, 2012, 2012
  • [25] Validation of Fluorescence Molecular Tomography/Micro-CT Multimodal Imaging In Vivo in Rats
    Daniel Vonwil
    Jon Christensen
    Sascha Fischer
    Olaf Ronneberger
    V. Prasad Shastri
    Molecular Imaging and Biology, 2014, 16 : 350 - 361
  • [26] Validation of Fluorescence Molecular Tomography/Micro-CT Multimodal Imaging In Vivo in Rats
    Vonwil, Daniel
    Christensen, Jon
    Fischer, Sascha
    Ronneberger, Olaf
    Shastri, V. Prasad
    MOLECULAR IMAGING AND BIOLOGY, 2014, 16 (03) : 350 - 361
  • [27] Imaging the healing murine myocardial infarct in vivo: ultrasound, magnetic resonance imaging and fluorescence molecular tomography
    Gray, Gillian A.
    White, Christopher I.
    Thomson, Adrian
    Kozak, Agnieszka
    Moran, Carmel
    Jansen, Maurits A.
    EXPERIMENTAL PHYSIOLOGY, 2013, 98 (03) : 606 - 613
  • [28] In vivo validation of free-space fluorescence tomography using nuclear imaging
    Garofalakis, Anikitos
    Dubois, Albertine
    Kuhnast, Bertrand
    Dupont, Daniel M.
    Janssens, Isabelle
    Mackiewicz, Nicolas
    Dolle, Frederic
    Tavitian, Bertrand
    Duconge, Frederic
    OPTICS LETTERS, 2010, 35 (18) : 3024 - 3026
  • [29] In vivo visualisation of tattoo particles using multiphoton tomography and fluorescence lifetime imaging
    Nguyen, Lynhda
    Mess, Christian
    Schneider, Stefan W.
    Huck, Volker
    Herberger, Katharina
    EXPERIMENTAL DERMATOLOGY, 2022, 31 (11) : 1712 - 1719
  • [30] In vivo imaging of integrin ανβ3 expression using fluorescence-mediated tomography
    von Wallbrunn, Angelika
    Hoeltke, Carsten
    Zuehlsdorf, Michael
    Heindel, Walter
    Schaefers, Michael
    Bremer, Christoph
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2007, 34 (05) : 745 - 754