Stokes parameters imaging of light reflected from biological tissue using polarization sensitive optical coherence tomography

被引:1
|
作者
de Boer, JF [1 ]
Milner, TE [1 ]
Nelson, JS [1 ]
机构
[1] Univ Calif Irvine, Beckman Laser Inst & Med Clin, Irvine, CA 92612 USA
关键词
optical coherence tomography; birefringence; stokes parameters; imaging;
D O I
10.1117/12.347482
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Polarization sensitive optical coherence tomography (PS-OCT) was used to determine the depth resolved Stokes parameters of light backscattered from highly scattering biological samples. Through simultaneous detection of the amplitude and relative phase of signal fringes in orthogonal polarization states formed by interference of light backscattered from turbid media and a mirror in the reference arm of a Michelson interferometer, changes in the Stokes parameters due to the optical phase delay between light propagating along the fast and slow axes of birefringent media were measured. Inasmuch as fibrous structures in many biological tissues influence the polarization state of light backscattered, PS-OCT is a potentially useful technique to image the structural properties of turbid biological materials. The method can also be applied to the investigation of birefringent properties in highly scattering materials such as ceramics and crystals.
引用
收藏
页码:140 / 144
页数:5
相关论文
共 50 条
  • [21] Polarization Sensitive Quantum Optical Coherence Tomography: Birefringence Imaging
    Sukharenko, Vitaly
    Bikorimana, Simeon
    Dorsinville, Roger
    2021 CONFERENCE ON LASERS AND ELECTRO-OPTICS (CLEO), 2021,
  • [22] Laryngeal Imaging with Polarization-sensitive Optical Coherence Tomography
    Burns, James A.
    Kim, Ki Hean
    Anderson, R. Rox
    PHOTONIC THERAPEUTICS AND DIAGNOSTICS VII, 2011, 7883
  • [23] Polarization contrast imaging of biological tissues by polarization-sensitive Fourier-domain optical coherence tomography
    Makita, S
    Yasuno, Y
    Endo, T
    Itoh, M
    Yatagai, T
    APPLIED OPTICS, 2006, 45 (06) : 1142 - 1147
  • [24] Birefringent tissue-mimicking phantom for polarization-sensitive optical coherence tomography imaging
    Chang, Shuang
    Handwerker, Jessica
    Giannico, Giovanna A.
    Chang, Sam S.
    Bowden, Audrey K.
    JOURNAL OF BIOMEDICAL OPTICS, 2022, 27 (07)
  • [25] Polarization-Sensitive Optical Coherence Tomography for Oral Squamous Cell Carcinoma Tissue Imaging
    Hu Muyun
    Yang Di
    Yang Zihan
    Shang Jianwei
    Zhang Jun
    Liang Yanmei
    ACTA OPTICA SINICA, 2022, 42 (10)
  • [26] Use of combined polarization-sensitive optical coherence tomography and Mueller matrix imaging for the polarimetric characterization of excised biological tissue
    Chue-Sang, Joseph
    Bai, Yuqiang
    Stoff, Susan
    Straton, David
    Ramaswamy, Sharan
    Ramella-Roman, Jessica C.
    JOURNAL OF BIOMEDICAL OPTICS, 2016, 21 (07)
  • [27] Polarization-Sensitive Optical Coherence Tomography using only Linearly Polarized Light
    Wen-Chuan Kuo
    Huan-Jang Huang
    Chih-Ming Lai
    Gwo-Jen Jan
    Chien Chou
    Optical and Quantum Electronics, 2005, 37 : 1213 - 1223
  • [28] Polarization-sensitive optical coherence tomography using only linearly polarized light
    Kuo, WC
    Huang, HJ
    Lai, CM
    Jan, GJ
    Chou, C
    OPTICAL AND QUANTUM ELECTRONICS, 2005, 37 (13-15) : 1213 - 1223
  • [29] Polarization Sensitive Spectral Interferometric Optical Coherence Tomography for Biological Samples
    Yoshiaki Yasuno
    Yasunori Sutoh
    Shuichi Makita
    Masahide Itoh
    Toyohiko Yatagai
    Optical Review, 2003, 10 : 498 - 500
  • [30] Polarization sensitive spectral interferometric optical coherence tomography for biological samples
    Yasuno, Y
    Sutoh, Y
    Makita, S
    Itoh, M
    Yatagai, T
    OPTICAL REVIEW, 2003, 10 (05) : 498 - 500