Indirect electrochemical detection of type-B trichothecene mycotoxins

被引:19
|
作者
Hsueh, CC [1 ]
Liu, Y [1 ]
Freund, MS [1 ]
机构
[1] Lehigh Univ, Dept Chem, Bethlehem, PA 18015 USA
关键词
D O I
10.1021/ac981114k
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Trichothecene mycotoxins in animal. feed and human food can cause fatalities in livestock and disease in humans. In addition, these toxins are suspected chemical warfare agents. Therefore, development of a simple and sensitive method for the screening of trichothecenes is important to prevent economic loss and health hazards. A simple and inexpensive method for the detection of type-B trichothecene mycotoxins has been developed in our laboratory. By hydrolyzing the toxin under basic conditions at 80 degrees C for 1 h it is possible to detect the toxin with simple electrochemical techniques. Deoxynivalenol (DON), commonly known as vomitoxin, was used as a representative compound for type-B trichothecenes in this detection scheme. The detection limit for DON using our procedures was determined to be 9.1 mu M in solution, corresponding to 0.24 ppm in a 25-g grain sample if the final extraction volume is 2.2 mi, The linear dynamic detection range was determined to be from 0.32 ppm to greater than 32 ppm. In addition to standard solutions, this method was used on rice samples spiked with DON, It was demonstrated that there is no electrochemical interference from rice extract and that 1 ppm of DON in rice samples can be quantified. This method may be ideal for toxin screening in animal feeds or in runoff from sites that produce the compounds as chemical warfare agents. Since the active moiety its DON is common to virtually all type-B trichothecenes, our approach may be ideal for type-specific screening.
引用
收藏
页码:4075 / 4080
页数:6
相关论文
共 50 条
  • [41] An Electrochemical Immunosensor for Rapid and Sensitive Detection of Mycotoxins Fumonisin B1 and Deoxynivalenol
    Lu, Lin
    Seenivasan, Rajesh
    Wang, Yi-Cheng
    Yu, Jae-Hyuk
    Gunasekaran, Sundaram
    ELECTROCHIMICA ACTA, 2016, 213 : 89 - 97
  • [42] RADIOIMMUNOASSAY FOR THE DETECTION OF ANTIBODY TO THE SURFACE-ANTIGEN OF HEPATITIS TYPE-B
    VYAZOV, SO
    DOROSHENKO, NV
    ZAIROV, GK
    VOLKOSH, LP
    ANANIEV, VA
    VOPROSY VIRUSOLOGII, 1980, (02) : 236 - 238
  • [43] Electrochemical aptasensing for the detection of mycotoxins in food commodities
    Katarína Nemčeková
    Veronika Svitková
    Gültekin Gökçe
    Monatshefte für Chemie - Chemical Monthly, 2022, 153 : 971 - 983
  • [44] DETECTION OF TYPE-A AND TYPE-B INFLUENZA-VIRUSES IN CLINICAL MATERIALS BY IMMUNOELECTRONMICROSCOPY
    PTAKOVA, M
    TUMOVA, B
    ACTA VIROLOGICA, 1985, 29 (01) : 19 - +
  • [45] PREVENTION OF TYPE-B HEPATITIS
    HOOFNAGLE, JH
    GASTROENTEROLOGY, 1979, 76 (06) : 1483 - 1485
  • [46] AFTER TYPE-B HEPATITIS
    不详
    BRITISH MEDICAL JOURNAL, 1975, 4 (5992): : 311 - 312
  • [47] CARRIER DETECTION IN SANFILIPPO SYNDROME TYPE-B - REPORT OF 6 FAMILIES
    VANCE, JM
    CONNEALLY, PM
    WAPPNER, RS
    YU, PL
    BRANDT, IK
    PERICAKVANCE, MA
    CLINICAL GENETICS, 1981, 20 (02) : 135 - 140
  • [48] ON THE CHARLIER TYPE-B SERIES
    KULLBACK, S
    ANNALS OF MATHEMATICAL STATISTICS, 1947, 18 (04): : 574 - 581
  • [49] TYPE-B HEPATITIS IN LAGOS
    MAJEKODUNMI, AE
    MABAYOJE, JO
    TROPICAL AND GEOGRAPHICAL MEDICINE, 1977, 29 (01): : 74 - 76
  • [50] PREVENTION OF HEPATITIS TYPE-B
    不详
    MEDICAL JOURNAL OF AUSTRALIA, 1976, 1 (11) : 332 - 334