Optimizing an inductively coupled plasma emission spectrometer analysis time with the use of a direct injection nebulizer

被引:4
|
作者
Vaughan, B
Claassen, L
机构
[1] Harris Laboratories, Lincoln, NE 68502
关键词
D O I
10.1080/00103629609369599
中图分类号
S3 [农学(农艺学)];
学科分类号
0901 ;
摘要
An inductively coupled plasma (ICP) emission spectrometer analysis time could be reduced if sample aspiration, spray chamber rinse, and equilibration time could be reduced. The objective of this project was to speed up ICP plant analysis time with a direct injection nebulizer (DIN; Cetac Technologies Inc., 5600 South 42nd St., Omaha, NE 68107) without sacrificing analytical accuracy. Plant samples were digested in a HNO3-H2O2 matrix and analyzed for their sulfur (S), phosphorus (P), potassium (K), sodium (Na), calcium (Ca), magnesium (Mg), zinc (Zn), manganese (Mn), copper (Cu), iron (Fe), boron (B), and aluminum (Al) content using a simultaneous Perkin Elmer Optima 3000 axial ICP. Sample throughput was increased to 5.3 samples per minute. To achieve this speed of analysis, the sample uptake was reduced to 3 sec/sample by using a vacuum pump to pull the sample through the system verses pushing the sample through with a peristaltic pump. Integration time was optimized at 2 sec/sample. Rinse time or equilibration which is usually necessary for normal spray chambers is 0 sec/sample with the DIN. These modifications did not sacrifice analytical quality when compared to referenced plant samples results. The vacuum pump/DIN/ICP system can reduce the normal ICP analysis dead-time to less than 3 sec/sample.
引用
收藏
页码:819 / 827
页数:9
相关论文
共 50 条
  • [21] Sonic Spray Nebulizer for Inductively Coupled Plasma Atomic Emission Spectrometry
    Min Huang
    Hisao Kojima
    Atsumu Hirabayashi
    Hideaki Koizumi
    Analytical Sciences, 1999, 15 : 265 - 268
  • [22] THE CONESPRAY NEBULIZER FOR INDUCTIVELY COUPLED PLASMA ATOMIC EMISSION-SPECTROMETRY
    IVALDI, JC
    VOLLMER, J
    SLAVIN, W
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 1991, 46 (6-7) : 1063 - 1072
  • [23] Sonic spray nebulizer for inductively coupled plasma atomic emission spectrometry
    Huang, M
    Kojima, H
    Hirabayashi, A
    Koizumi, H
    ANALYTICAL SCIENCES, 1999, 15 (03) : 265 - 268
  • [24] Modified Babington nebulizer for inductively coupled plasma atomic emission spectrometry
    Isoyama, H
    Uchida, T
    Nagashima, T
    Ohira, O
    ANALYTICAL SCIENCES, 2003, 19 (04) : 593 - 597
  • [25] Development of a direct hydride generation nebulizer for the determination of selenium by inductively coupled plasma optical emission spectrometry
    Carrión, N
    Murillo, M
    Montiel, E
    Díaz, D
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2003, 58 (08) : 1375 - 1389
  • [26] Direct injection nebulizer-coupled microwave-induced plasma for atomic emission spectroscopy
    Ng, KC
    Culp, RC
    APPLIED SPECTROSCOPY, 1997, 51 (10) : 1447 - 1452
  • [27] Determination of organotin compounds by liquid chromatography-inductively coupled plasma mass spectrometry with a direct injection nebulizer
    Chao, WS
    Jiang, SJ
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1998, 13 (12) : 1337 - 1341
  • [28] USE OF A THERMOSPRAY NEBULIZER AS A SAMPLE INTRODUCTION SYSTEM FOR INDUCTIVELY COUPLED PLASMA ATOMIC EMISSION-SPECTROMETRY
    VERMEIREN, KA
    TAYLOR, PDP
    DAMS, R
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1987, 2 (04) : 383 - 387
  • [29] A novel concentric grid nebulizer for inductively coupled plasma optical emission spectrometry
    Inagaki, Kazumi
    Fujii, Shin-ichiro
    Miyashita, Shin-ichi
    Nagasawa, Keisuke
    Okahashi, Tetsuya
    Groombridge, Alexander S.
    Takatsu, Akiko
    Chiba, Koichi
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2014, 29 (11) : 2136 - 2145
  • [30] A novel concentric grid nebulizer for inductively coupled plasma optical emission spectrometry
    Inagaki, Kazumi, 1600, Royal Society of Chemistry (29):