Total surgical aortic arch replacement as a safe strategy to treat complex multisegmental proximal thoracic aortic pathology

被引:9
|
作者
Czerny, Martin [1 ]
Koenig, Tobias [1 ]
Reineke, David [1 ]
Sodeck, Gottfried H. [2 ]
Rieger, Maximilian [1 ]
Schoenhoff, Florian [1 ]
Basciani, Reto [3 ]
Jenni, Hansjoerg [1 ]
Schmidli, Juerg [1 ]
Carrel, Thierry P. [1 ]
机构
[1] Univ Hosp Bern, Dept Cardiovasc Surg, CH-3010 Bern, Switzerland
[2] Med Univ Vienna, Dept Emergency Med, Vienna, Austria
[3] Univ Hosp Bern, Dept Anesthesiol, CH-3010 Bern, Switzerland
关键词
Aortic arch surgery; Multisegmental thoracic aortic pathology; Aneurysm; Dissection; SELECTIVE CEREBRAL PERFUSION; ENDOVASCULAR REPAIR; DISSECTION; SURGERY;
D O I
10.1093/icvts/ivt260
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
OBJECTIVE: To analyse the results after elective open total aortic arch replacement. METHODS: We analysed 39 patients (median age 63 years, median logistic EuroSCORE 18.4) who underwent elective open total arch replacement between 2005 and 2012. RESULTS: In-hospital mortality was 5.1% (n = 2) and perioperative neurological injury was 12.8% (n = 5). The indication for surgery was degenerative aneurysmal disease in 59% (n = 23) and late aneurysmal formation following previous surgery of type A aortic dissection in 35.9% (n = 14); 5.1% (n = 2) were due to anastomotical aneurysms after prior ascending repair. Fifty-nine percent (n = 23) of the patients had already undergone previous proximal thoracic aortic surgery. In 30.8% (n = 12) of them, a conventional elephant trunk was added to total arch replacement, in 28.2% (n = 11), root replacement was additionally performed. Median hypothermic circulatory arrest time was 42 min (21-54 min). Selective antegrade cerebral perfusion was used in 95% (n = 37) of patients. Median follow-up was 11 months [interquartile range (IQR) 1-20 months]. There was no late death and no need for reoperation during this period. CONCLUSIONS:Open total aortic arch replacement shows very satisfying results. The number of patients undergoing total arch replacement as a redo procedure and as a part of a complex multisegmental aortic pathology is high. Future strategies will have to emphasize neurological protection in extensive simultaneous replacement of the aortic arch and adjacent segments.
引用
收藏
页码:532 / 536
页数:5
相关论文
共 50 条
  • [41] One-Stage Hybrid Total Aortic Arch and Descending Thoracic Aortic Repair is a Safe and Secure Procedure With Less Postoperative Complications for Extended Aortic Arch Aneurysms
    Mizuno, Tomohiro
    Hachimaru, Tsuyoshi
    Fujiwara, Tatsuki
    Oishi, Kiyotoshi
    Takeshita, Masashi
    Yashima, Masafumi
    Okumura, Yushi
    Nagaoka, Eiki
    Oi, Keiji
    Arai, Hirokuni
    JOURNAL OF ENDOVASCULAR THERAPY, 2022, 29 (02) : 204 - 214
  • [42] Aortic balloon occlusion technique in total arch replacement with frozen elephant trunk after thoracic endovascular aortic repair
    Dun, Yaojun
    Shi, Yi
    Guo, Hongwei
    Liu, Yanxiang
    Zhang, Bowen
    Sun, Xiaogang
    JOURNAL OF THORACIC DISEASE, 2020, 12 (05) : 2474 - 2481
  • [43] Surgical management of acute type A aortic dissection: branch-first arch replacement with total aortic repair
    Galvin, Sean D.
    Perera, Nisal K.
    Matalanis, George
    ANNALS OF CARDIOTHORACIC SURGERY, 2016, 5 (03) : 236 - 244
  • [44] The strategy of cardiopulmonary bypass for total aortic arch replacement and the frozen elephant trunk technique with aortic balloon occlusion
    Li, Yunfeng
    Yan, Shujie
    Lou, Song
    Sun, Xiaogang
    JOURNAL OF INTERNATIONAL MEDICAL RESEARCH, 2020, 48 (05)
  • [45] Prevalence of Bovine Aortic Arch Configuration in Adult Patients with and without Thoracic Aortic Pathology
    Moorehead, Pamela A.
    Kim, Ann H.
    Miller, Claire P.
    Kashyap, Tejas V.
    Kendrick, Daniel E.
    Kashyap, Vikram S.
    ANNALS OF VASCULAR SURGERY, 2016, 30 : 132 - 137
  • [46] Off-Pump Debranching and Thoracic Endovascular Aortic Repair for Aortic Arch Pathology
    Ghazy, Tamer
    Mashhour, Ahmed
    Schmidt, Torsten
    Mahlmann, Adrian
    Ouda, Ahmed
    Florek, Hans-Joachim
    Matschke, Klaus
    Kappert, Utz
    INNOVATIONS-TECHNOLOGY AND TECHNIQUES IN CARDIOTHORACIC AND VASCULAR SURGERY, 2015, 10 (03) : 163 - 169
  • [47] Aortic root and proximal aortic arch replacement (performed by a left-handed surgeon)
    Carrel, Thierry
    INTERACTIVE CARDIOVASCULAR AND THORACIC SURGERY, 2017, 24 (01) : 158 - 160
  • [48] Proximal and extended aortic arch replacement in acute DeBakey type I aortic dissection
    Narita, Masahiko
    Tsutsui, Masahiro
    Ushioda, Ryouhei
    Kikuchi, Yuta
    Shirasaka, Tomonori
    Ishikawa, Natsuya
    Kamiya, Hiroyuki
    FRONTIERS IN SURGERY, 2023, 10
  • [49] Transthoracic Ultrasound Evaluation of Arch and Descending Thoracic Aortic Pathology
    D'Abate, Fabrizio
    Oladokun, Dare
    La Leggia, Angelo
    Hinchliffe, Robert
    Thompson, Matthew
    Holt, Peter
    de Bruin, Jorg
    Loftus, Ian
    Patterson, Benjamin
    EUROPEAN JOURNAL OF VASCULAR AND ENDOVASCULAR SURGERY, 2018, 55 (05) : 658 - 665
  • [50] Thoracic Endovascular Repair (TEVAR) in the Management of Aortic Arch Pathology
    Murphy, Erin H.
    Stanley, Gregory A.
    Ilves, Mihaiela
    Knowles, Martyn
    Dimaio, J. Michael
    Jessen, Michael E.
    Arko, Frank R., III
    ANNALS OF VASCULAR SURGERY, 2012, 26 (01) : 55 - 66