Microelectrode for in vivo real-time detection of NO

被引:9
|
作者
Dalbasti, T [1 ]
Kilinc, E
机构
[1] Univ Ege, Sch Med, Dept Neurosurg, TR-35100 Izmir, Turkey
[2] Univ Ege, Sch Pharm, Dept Analyt Chem, TR-35100 Izmir, Turkey
来源
NITRIC OXIDE, PT E | 2005年 / 396卷
关键词
D O I
10.1016/S0076-6879(05)96050-3
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Nitric oxide (NO) is gaining importance with its diverse spectrum of clinic effects. However, there is still a need for an ideal sensor to monitor its concentration in tissue. An ideal sensor should not interfere with the ongoing physiological process, while making fast, reliable, and repeatable measurements. We have designed a microelectrode for electrochemical NO measurement from tissue with relatively low interference and reliable results upon calibration. Details of electrode preparation and calibration procedure are explained along with an experiment to monitor effects of photodynamic therapy.
引用
收藏
页码:584 / 592
页数:9
相关论文
共 50 条
  • [1] Real-time Detection and Quantitation of siRNAs in vivo
    Cheng, A.
    Liang, Y.
    Vlassov, A.
    Li, M.
    Wang, Y.
    Wong, L.
    Chen, C.
    Magdaleno, S.
    NSTI NANOTECH 2008, VOL 2, TECHNICAL PROCEEDINGS, 2008, : 427 - 429
  • [2] In vivo real-time measurement of local drug concentrations by using diamond microelectrode
    Ogata, Genki
    Ishii, Yuya
    Asai, Kai
    Sano, Yamato
    Nin, Fumiaki
    Yoshida, Takamasa
    Komune, Shizuo
    Takai, Madoka
    Kusuhara, Hiroyuki
    Einaga, Yasuaki
    Hibino, Hiroshi
    JOURNAL OF PHARMACOLOGICAL SCIENCES, 2016, 130 (03) : S32 - S32
  • [3] Real-time in vivo detection of myocyte apoptosis
    Grosso, M.
    Ranji, M.
    Kanemoto, S.
    Matsubara, M.
    Chance, B.
    Gorman, R.
    Gorman, J.
    JOURNAL OF CARDIAC FAILURE, 2006, 12 (06) : S13 - S14
  • [4] Real-time in vivo detection techniques for neurotransmitters: a review
    Su, Yi
    Bian, Sumin
    Sawan, Mohamad
    ANALYST, 2020, 145 (19) : 6193 - 6210
  • [5] DEVOLPMENT OF A NOVEL NEUROMONITOR FOR CLINICAL TBI RESEARCH: ENZYME-BASED MICROELECTRODE ARRAY FOR REAL-TIME IN VIVO DETECTION OF NEUROCHEMICALS
    Hinzman, Jason
    Quintero, Jorge
    Burmeister, Jason
    Stephens, Michelle
    Zhang, Zhming
    Hartings, Jed
    Lifshitz, Jonathan
    Gerhardt, Greg
    JOURNAL OF NEUROTRAUMA, 2012, 29 (10) : A115 - A116
  • [6] An interdigitated microelectrode based aptasensor for real-time and ultratrace detection of four organophosphorus pesticides
    Zhang, Jian
    Fang, Xiaobo
    Wu, Jayne
    Hu, Zhiwen
    Jiang, Yu
    Qi, Haochen
    Zheng, Lei
    Xuan, Xiaofeng
    BIOSENSORS & BIOELECTRONICS, 2020, 150
  • [7] Real-time in vivo detection of retinal reactive oxygen species
    Fan, Ning
    Liu, Yang
    Kim, Byung-Jin
    Tang, Liping
    Clark, Abbot F.
    Pang, Iok-Hou
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2015, 56 (07)
  • [8] Real-time Detection for Multiple Occupancy and Near Real-time Hogging Detection
    Huy, Nguyen Huy Hoang
    Balan, Rajesh Krishna
    Lee, Youngki
    SenSys'15: Proceedings of the 13th ACM Conference on Embedded Networked Sensor Systems, 2015, : 477 - 478
  • [9] A microsensing system for the in vivo real-time detection of local drug kinetics
    Ogata, Genki
    Ishii, Yuya
    Asai, Kai
    Sano, Yamato
    Nin, Fumiaki
    Yoshida, Takamasa
    Higuchi, Taiga
    Sawamura, Seishiro
    Ota, Takeru
    Hori, Karin
    Maeda, Kazuya
    Komune, Shizuo
    Doi, Katsumi
    Takai, Madoka
    Findlay, Ian
    Kusuhara, Hiroyuki
    Einaga, Yasuaki
    Hibino, Hiroshi
    NATURE BIOMEDICAL ENGINEERING, 2017, 1 (08): : 654 - 666
  • [10] In vivo flow cytometer for real-time detection and quantification of circulating cells
    Novak, J
    Georgakoudi, I
    Wei, X
    Prossin, A
    Lin, CP
    OPTICS LETTERS, 2004, 29 (01) : 77 - 79