Quality And Feasibility of Sonographic Measurement of the Optic Nerve Sheath Diameter to Estimate the Risk of Raised Intracranial Pressure After Traumatic Brain Injury in Prehospital Setting

被引:20
|
作者
Houze-Cerfon, Charles-Henri [1 ]
Bounes, Vincent [1 ,2 ]
Guemon, Johanna [3 ]
Le Gourrierec, Thibault [1 ]
Geeraerts, Thomas [4 ,5 ]
机构
[1] Univ Hosp Toulouse, Emergency Dept, SAMU 31, Toulouse, France
[2] Univ Paul Sabatier Toulouse 3, Lab Clin & Med Pharmacol, Toulouse, France
[3] Hosp Ctr Montauban, Emergency Dept, Montauban, France
[4] Univ Hosp Toulouse, Dept Anaesthesia & Intens Care, Toulouse, France
[5] INSERM, Toulouse NeuroImaging Ctr, UMR 1214, UPS,ToNIC, Toulouse, France
关键词
sonographic; traumatic brain injury; prehospital; ULTRASOUND; MANAGEMENT; ULTRASONOGRAPHY; EPIDEMIOLOGY;
D O I
10.1080/10903127.2018.1501444
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Objective: In patients with traumatic brain injury (TBI), early detection and subsequent prompt treatment of elevated intracranial pressure (ICP) is a challenge in the prehospital setting, because physical examination is limited in comatose patients and invasive device placement is not possible. The aim of this study was to evaluate the quality and feasibility of optic nerve sheath diameter (ONSD) measurements obtained during the prehospital management of patients with TBI. Methods: This study was a prospective, observational study of 23 patients with moderate and severe TBI during prehospital medical care. The primary endpoint was the quality of ONSD measurements expressed as the percentage of ONSD validated by the experts. Secondary endpoints included the feasibility of ONSD measurements as the percentage of ONSD performed and assessment by operators of ease and duration to perform. Results: Ultrasound ONSD was performed in 19 (82%) patients and 80% of ONSD measurements were validated by the experts. The ONSD measurements were possible in 15 (79%) cases. The physicians have assessed the ease of use at 8 (interquartile range [IQR] = 2.5-8) on 10 for and the median time to obtain ONSD measurement was 4 min (IQR = 3-5). ONSD measurement was performed in 12 (63%) cases during the transport and in 7 (37%) cases on scene, with 58% (n = 7) and 71% (n = 5) validated ONSD, respectively. The success rate in the helicopter was 43% compared to 80% in the ambulance. Conclusion: This study shows that it is feasible to obtain high-quality ONSD measurements in the management of patients with TBI in a prehospital setting. A randomized study evaluating the usefulness of ONSD to guide management of TBI in the prehospital phase may be of great interest.
引用
收藏
页码:277 / 283
页数:7
相关论文
共 50 条
  • [31] Ultrasonography of the optic nerve sheath may be useful for detecting raised intracranial pressure after severe brain injury
    Thomas Geeraerts
    Yoann Launey
    Laurent Martin
    Julien Pottecher
    Bernard Vigué
    Jacques Duranteau
    Dan Benhamou
    Intensive Care Medicine, 2007, 33 : 1704 - 1711
  • [32] Standardized Ultrasonographic Measurement of Optic Nerve Sheath Diameter in Traumatic Brain Injury Patients
    Graziano, Mario
    Sannino, Ciro
    Mottola, Francesco Ferdinando
    NEUROLOGY INDIA, 2023, 71 (04) : 792 - 792
  • [33] Ultrasound measurement of the optic nerve sheath diameter in traumatic brain injury: a narrative review
    Natile, M.
    Simonet, O.
    Vallot, F.
    De Kock, M.
    ACTA ANAESTHESIOLOGICA BELGICA, 2021, 72 (04) : 151 - 168
  • [34] Intracranial Pressure Assessment in Traumatic Head Injury with Hemorrhage Via Optic Nerve Sheath Diameter
    Vaiman, Michael
    Sigal, Tal
    Kimiagar, Itzhak
    Bekerman, Inessa
    JOURNAL OF NEUROTRAUMA, 2016, 33 (23) : 2147 - 2153
  • [35] Ultrasound measurement of the optic nerve sheath diameter for monitoring patients with raised intracranial pressure - a case report
    Bender, M.
    Lakicevic, S.
    Radancevic, D.
    Malojcic, B.
    EUROPEAN JOURNAL OF NEUROLOGY, 2018, 25 : 58 - 59
  • [36] Measurement of optic nerve sheath diameter by ultrasound: a means of detecting acute raised intracranial pressure in hydrocephalus
    Newman, WD
    Hollman, AS
    Dutton, GN
    Carachi, R
    BRITISH JOURNAL OF OPHTHALMOLOGY, 2002, 86 (10) : 1109 - 1113
  • [37] Pcv-aCO2/Ca-cvO2 Combined with Optic Nerve Sheath Diameter in Predicting Elevated Intracranial Pressure of Patients with Traumatic Brain Injury in Prehospital Setting
    Jiang, Hui
    Xie, Zhihui
    Yang, Liu
    Wang, Huiting
    INTERNATIONAL JOURNAL OF GENERAL MEDICINE, 2024, 17 : 4519 - 4528
  • [38] ASSOCIATION BETWEEN OPTIC NERVE SHEATH DIAMETER ON COMPUTED TOMOGRAPHY AND INTRACRANIAL PRESSURE IN PATIENTS WITH SEVERE TRAUMATIC BRAIN INJURY
    Sekhon, M. S.
    Griesdale, D. E.
    Robba, C.
    Needham, E.
    Walland, K.
    McGlashan, N.
    Mossallum, R.
    Menon, D. K.
    INTENSIVE CARE MEDICINE, 2014, 40 : S19 - S19
  • [39] Correlation of optic nerve sheath diameter with direct measurement of intracranial pressure
    Kimberly, Heidi Harbison
    Shah, Sachita
    Marill, Keith
    Noble, Vicki
    ACADEMIC EMERGENCY MEDICINE, 2008, 15 (02) : 201 - 204
  • [40] Optic Nerve Sheath Diameter with Intracranial Hypertension in Patients with Traumatic Head Injury
    Al-Hassani, Ammar
    El-Menyar, Ayman
    Al-Thani, Hassan
    JOURNAL OF THE AMERICAN COLLEGE OF SURGEONS, 2019, 229 (04) : S191 - S191