Quality And Feasibility of Sonographic Measurement of the Optic Nerve Sheath Diameter to Estimate the Risk of Raised Intracranial Pressure After Traumatic Brain Injury in Prehospital Setting

被引:20
|
作者
Houze-Cerfon, Charles-Henri [1 ]
Bounes, Vincent [1 ,2 ]
Guemon, Johanna [3 ]
Le Gourrierec, Thibault [1 ]
Geeraerts, Thomas [4 ,5 ]
机构
[1] Univ Hosp Toulouse, Emergency Dept, SAMU 31, Toulouse, France
[2] Univ Paul Sabatier Toulouse 3, Lab Clin & Med Pharmacol, Toulouse, France
[3] Hosp Ctr Montauban, Emergency Dept, Montauban, France
[4] Univ Hosp Toulouse, Dept Anaesthesia & Intens Care, Toulouse, France
[5] INSERM, Toulouse NeuroImaging Ctr, UMR 1214, UPS,ToNIC, Toulouse, France
关键词
sonographic; traumatic brain injury; prehospital; ULTRASOUND; MANAGEMENT; ULTRASONOGRAPHY; EPIDEMIOLOGY;
D O I
10.1080/10903127.2018.1501444
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Objective: In patients with traumatic brain injury (TBI), early detection and subsequent prompt treatment of elevated intracranial pressure (ICP) is a challenge in the prehospital setting, because physical examination is limited in comatose patients and invasive device placement is not possible. The aim of this study was to evaluate the quality and feasibility of optic nerve sheath diameter (ONSD) measurements obtained during the prehospital management of patients with TBI. Methods: This study was a prospective, observational study of 23 patients with moderate and severe TBI during prehospital medical care. The primary endpoint was the quality of ONSD measurements expressed as the percentage of ONSD validated by the experts. Secondary endpoints included the feasibility of ONSD measurements as the percentage of ONSD performed and assessment by operators of ease and duration to perform. Results: Ultrasound ONSD was performed in 19 (82%) patients and 80% of ONSD measurements were validated by the experts. The ONSD measurements were possible in 15 (79%) cases. The physicians have assessed the ease of use at 8 (interquartile range [IQR] = 2.5-8) on 10 for and the median time to obtain ONSD measurement was 4 min (IQR = 3-5). ONSD measurement was performed in 12 (63%) cases during the transport and in 7 (37%) cases on scene, with 58% (n = 7) and 71% (n = 5) validated ONSD, respectively. The success rate in the helicopter was 43% compared to 80% in the ambulance. Conclusion: This study shows that it is feasible to obtain high-quality ONSD measurements in the management of patients with TBI in a prehospital setting. A randomized study evaluating the usefulness of ONSD to guide management of TBI in the prehospital phase may be of great interest.
引用
收藏
页码:277 / 283
页数:7
相关论文
共 50 条
  • [1] Optic nerve sheath measurement and raised intracranial pressure in paediatric traumatic brain injury
    Agrawal, S.
    Brierley, J.
    EUROPEAN JOURNAL OF TRAUMA AND EMERGENCY SURGERY, 2012, 38 (01) : 75 - 77
  • [2] Optic nerve sheath measurement and raised intracranial pressure in paediatric traumatic brain injury
    S. Agrawal
    J. Brierley
    European Journal of Trauma and Emergency Surgery, 2012, 38 : 75 - 77
  • [3] Use of the sonographic diameter of optic nerve sheath to estimate intracranial pressure
    Amini, Afshin
    Kariman, Hamid
    Dolatabadi, Ali Arhami
    Hatamabadi, Hamid Reza
    Derakhshanfar, Hojjat
    Mansouri, Behnam
    Safari, Saeed
    Eqtesadi, Razie
    AMERICAN JOURNAL OF EMERGENCY MEDICINE, 2013, 31 (01): : 236 - 239
  • [4] Ratio of Optic Nerve Sheath Diameter to Eyeball Transverse Diameter by Ultrasonography to Predict Raised Intracranial Pressure in Traumatic Brain Injury
    Livio Vitiello
    Maddalena De Bernardo
    Nicola Rosa
    Neurocritical Care, 2019, 31 : 592 - 593
  • [5] Sonographic Optic Nerve Sheath Diameter as an Estimate of Intracranial Pressure in Adult Trauma
    Strumwasser, Aaron
    Kwan, Rita O.
    Yeung, Louise
    Miraflor, Emily
    Ereso, Alex
    Castro-Moure, Frederico
    Patel, Atul
    Sadjadi, Javid
    Victorino, Gregory P.
    JOURNAL OF SURGICAL RESEARCH, 2011, 170 (02) : 265 - 271
  • [6] Ratio of Optic Nerve Sheath Diameter to Eyeball Transverse Diameter by Ultrasonography to Predict Raised Intracranial Pressure in Traumatic Brain Injury
    Vitiello, Livio
    De Bernardo, Maddalena
    Rosa, Nicola
    NEUROCRITICAL CARE, 2019, 31 (03) : 592 - 593
  • [7] OPTIC NERVE SHEATH DIAMETER: SURROGATE FOR INTRACRANIAL PRESSURE IN PEDIATRIC TRAUMATIC BRAIN INJURY
    Patten, William
    Chen, Jerome
    Carcamo, Wendy
    Ben Khallouq, Bee
    Olavarria, Greg
    Elbabaa, Samer
    CRITICAL CARE MEDICINE, 2022, 50 (01) : 792 - 792
  • [8] Predictive value of optic nerve sheath diameter measurement for detecting raised intracranial pressure in paediatric traumatic brain injury: A prospective observational study
    Padayachy, Vaishali
    Van As, Sebastian
    Padayachy, Llewellyn
    BRAIN INJURY, 2016, 30 (5-6) : 589 - 589
  • [9] Optic nerve sheath diameter measurement for predicting raised intracranial pressure in adult patients with severe traumatic brain injury: A meta-analysis
    Lee, Sun Hwa
    Kim, Hyun Soo
    Yun, Seong Jong
    JOURNAL OF CRITICAL CARE, 2020, 56 : 182 - 187
  • [10] Correlating optic nerve sheath diameter with opening intracranial pressure in pediatric traumatic brain injury
    Adam M.H. Young
    Mathew R. Guilfoyle
    Joseph Donnelly
    Daniel Scoffings
    Helen Fernandes
    Mathew Garnett
    Shruti Agrawal
    Peter J. Hutchinson
    Pediatric Research, 2017, 81 : 443 - 447