Biomechanics and energetics of walking in powered ankle exoskeletons using myoelectric control versus mechanically intrinsic control

被引:40
|
作者
Koller, Jeffrey R. [1 ]
Remy, C. David [1 ]
Ferris, Daniel P. [2 ,3 ]
机构
[1] Univ Michigan, Dept Mech Engn, 2350 Hayward, Ann Arbor, MI 48109 USA
[2] Univ Florida, J Crayton Pruitt Family Dept Biomed Engn, 1275 Ctr Dr, Gainesville, FL 32611 USA
[3] Univ Florida, Dept Mech Engn, 1275 Ctr Dr, Gainesville, FL 32611 USA
关键词
Exoskeleton Control; Gait; Kinematics; Power; Electromyography; METABOLIC COST; ASSISTANCE; EMG;
D O I
10.1186/s12984-018-0379-6
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Background: Controllers for assistive robotic devices can be divided into two main categories: controllers using neural signals and controllers using mechanically intrinsic signals. Both approaches are prevalent in research devices, but a direct comparison between the two could provide insight into their relative advantages and disadvantages. We studied subjects walking with robotic ankle exoskeletons using two different control modes: dynamic gain proportional myoelectric control based on soleus muscle activity (neural signal), and timing-based mechanically intrinsic control based on gait events (mechanically intrinsic signal). We hypothesized that subjects would have different measures of metabolic work rate between the two controllers as we predicted subjects would use each controller in a unique manner due to one being dependent on muscle recruitment and the other not. Methods: The two controllers had the same average actuation signal as we used the control signals from walking with the myoelectric controller to shape the mechanically intrinsic control signal. The difference being the myoelectric controller allowed step-to-step variation in the actuation signals controlled by the user's soleus muscle recruitment while the timing-based controller had the same actuation signal with each step regardless of muscle recruitment. Results: We observed no statistically significant difference in metabolic work rate between the two controllers. Subjects walked with 11% less soleus activity during mid and late stance and significantly less peak soleus recruitment when using the timing-based controller than when using the myoelectric controller. While walking with the myoelectric controller, subjects walked with significantly higher average positive and negative total ankle power compared to walking with the timing-based controller. Conclusions: We interpret the reduced ankle power and muscle activity with the timing-based controller relative to the myoelectric controller to result from greater slacking effects. Subjects were able to be less engaged on a muscle level when using a controller driven by mechanically intrinsic signals than when using a controller driven by neural signals, but this had no affect on their metabolic work rate. These results suggest that the type of controller (neural vs. mechanical) is likely to affect how individuals use robotic exoskeletons for therapeutic rehabilitation or human performance augmentation.
引用
收藏
页数:14
相关论文
共 38 条
  • [31] Visual Feedback Control of a Rat Ankle Angle Using a Wirelessly Powered Two-Channel Neurostimulator
    Takeuchi, Masaru
    Watanabe, Keita
    Ishihara, Kanta
    Miyamoto, Taichi
    Tokutake, Katsuhiro
    Saeki, Sota
    Aoyama, Tadayoshi
    Hasegawa, Yasuhisa
    Kurimoto, Shigeru
    Hirata, Hitoshi
    SENSORS, 2020, 20 (08)
  • [32] Promise of using surface EMG signals to volitionally control ankle joint position for powered transtibial prostheses
    Chen, Baojun
    Wang, Qining
    Wang, Long
    2014 36TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2014, : 2545 - 2548
  • [33] Optimal Control Based Stiffness Identification of an Ankle-Foot Orthosis Using a Predictive Walking Model
    Sreenivasa, Manish
    Millard, Matthew
    Felis, Martin
    Mombaur, Katja
    Wolf, Sebastian I.
    FRONTIERS IN COMPUTATIONAL NEUROSCIENCE, 2017, 11 : 1 - 13
  • [34] Characterizing Prosthesis Control Fault During Human-Prosthesis Interactive Walking Using Intrinsic Sensors
    Naseri, Amirreza
    Liu, Ming
    Lee, I-Chieh
    Liu, Wentao
    Huang, He
    IEEE ROBOTICS AND AUTOMATION LETTERS, 2022, 7 (03): : 8307 - 8314
  • [35] Using Virtual Model Control and Genetic Algorithm to Obtain Stable Bipedal Walking Gait Through Optimizing the Ankle Torque
    Dau, Van-Huan
    Chew, Chee-Meng
    Poo, Aun-Neow
    ADVANCES IN CLIMBING AND WALKING ROBOTS, PROCEEDINGS, 2007, : 466 - 474
  • [36] Powered prosthesis control during walking, sitting, standing, and non-weight bearing activities using neural and mechanical inputs
    Simon, Ann M.
    Fey, Nicholas P.
    Ingraham, Kimberly A.
    Young, Aaron J.
    Hargrove, Levi J.
    2013 6TH INTERNATIONAL IEEE/EMBS CONFERENCE ON NEURAL ENGINEERING (NER), 2013, : 1174 - 1177
  • [37] Impedance Control Strategies for Enhancing Sloped and Level Walking Capabilities for Individuals with Transfemoral Amputation Using a Powered Multi-Joint Prosthesis
    Bhakta, Krishan
    Camargo, Jonathan
    Kunapuli, Pratik
    Childers, Lee
    Young, Aaron
    MILITARY MEDICINE, 2020, 185 : 490 - 499
  • [38] Effects of technological running shoes versus barefoot running on the intrinsic foot muscles, ankle mobility, and dynamic control: a novel cross-sectional research
    Garcia-Arrab, Maria
    Batuecas-Sanchez, Ivan
    de Vidania, Silvia
    Bravo-Aguilar, Maria
    Ruiz-Ruiz, Beatriz
    Romero-Morales, Carlos
    BRAZILIAN JOURNAL OF PHYSICAL THERAPY, 2024, 28 (04)