Biomechanics and energetics of walking in powered ankle exoskeletons using myoelectric control versus mechanically intrinsic control

被引:40
|
作者
Koller, Jeffrey R. [1 ]
Remy, C. David [1 ]
Ferris, Daniel P. [2 ,3 ]
机构
[1] Univ Michigan, Dept Mech Engn, 2350 Hayward, Ann Arbor, MI 48109 USA
[2] Univ Florida, J Crayton Pruitt Family Dept Biomed Engn, 1275 Ctr Dr, Gainesville, FL 32611 USA
[3] Univ Florida, Dept Mech Engn, 1275 Ctr Dr, Gainesville, FL 32611 USA
关键词
Exoskeleton Control; Gait; Kinematics; Power; Electromyography; METABOLIC COST; ASSISTANCE; EMG;
D O I
10.1186/s12984-018-0379-6
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Background: Controllers for assistive robotic devices can be divided into two main categories: controllers using neural signals and controllers using mechanically intrinsic signals. Both approaches are prevalent in research devices, but a direct comparison between the two could provide insight into their relative advantages and disadvantages. We studied subjects walking with robotic ankle exoskeletons using two different control modes: dynamic gain proportional myoelectric control based on soleus muscle activity (neural signal), and timing-based mechanically intrinsic control based on gait events (mechanically intrinsic signal). We hypothesized that subjects would have different measures of metabolic work rate between the two controllers as we predicted subjects would use each controller in a unique manner due to one being dependent on muscle recruitment and the other not. Methods: The two controllers had the same average actuation signal as we used the control signals from walking with the myoelectric controller to shape the mechanically intrinsic control signal. The difference being the myoelectric controller allowed step-to-step variation in the actuation signals controlled by the user's soleus muscle recruitment while the timing-based controller had the same actuation signal with each step regardless of muscle recruitment. Results: We observed no statistically significant difference in metabolic work rate between the two controllers. Subjects walked with 11% less soleus activity during mid and late stance and significantly less peak soleus recruitment when using the timing-based controller than when using the myoelectric controller. While walking with the myoelectric controller, subjects walked with significantly higher average positive and negative total ankle power compared to walking with the timing-based controller. Conclusions: We interpret the reduced ankle power and muscle activity with the timing-based controller relative to the myoelectric controller to result from greater slacking effects. Subjects were able to be less engaged on a muscle level when using a controller driven by mechanically intrinsic signals than when using a controller driven by neural signals, but this had no affect on their metabolic work rate. These results suggest that the type of controller (neural vs. mechanical) is likely to affect how individuals use robotic exoskeletons for therapeutic rehabilitation or human performance augmentation.
引用
收藏
页数:14
相关论文
共 38 条
  • [1] Biomechanics and energetics of walking in powered ankle exoskeletons using myoelectric control versus mechanically intrinsic control
    Jeffrey R. Koller
    C. David Remy
    Daniel P. Ferris
    Journal of NeuroEngineering and Rehabilitation, 15
  • [2] Comparing Neural Control and Mechanically Intrinsic Control of Powered Ankle Exoskeletons
    Koller, Jeffrey R.
    Remy, C. David
    Ferris, Daniel P.
    2017 INTERNATIONAL CONFERENCE ON REHABILITATION ROBOTICS (ICORR), 2017, : 294 - 299
  • [3] Mechanics and energetics of level walking with powered ankle exoskeletons
    Sawicki, Gregory S.
    Ferris, Daniel P.
    JOURNAL OF EXPERIMENTAL BIOLOGY, 2008, 211 (09): : 1402 - 1413
  • [4] Neuromechanical Adaptation to Walking With Electromechanical Ankle Exoskeletons Under Proportional Myoelectric Control
    Hybart, Rachel L.
    Ferris, Daniel P.
    IEEE OPEN JOURNAL OF ENGINEERING IN MEDICINE AND BIOLOGY, 2023, 4 : 119 - 128
  • [5] Mechanics and energetics of post-stroke walking aided by a powered ankle exoskeleton with speed-adaptive myoelectric control
    Emily M. McCain
    Taylor J. M. Dick
    Tracy N. Giest
    Richard W. Nuckols
    Michael D. Lewek
    Katherine R. Saul
    Gregory S. Sawicki
    Journal of NeuroEngineering and Rehabilitation, 16
  • [6] Mechanics and energetics of post-stroke walking aided by a powered ankle exoskeleton with speed-adaptive myoelectric control
    McCain, Emily M.
    Dick, Taylor J. M.
    Giest, Tracy N.
    Nuckols, Richard W.
    Lewek, Michael D.
    Saul, Katherine R.
    Sawicki, Gregory S.
    JOURNAL OF NEUROENGINEERING AND REHABILITATION, 2019, 16 (1)
  • [7] Metabolic cost of walking with electromechanical ankle exoskeletons under proportional myoelectric control on a treadmill and outdoors
    Hybart, Rachel
    Villancio-Wolter, K. Siena
    Ferris, Daniel Perry
    PEERJ, 2023, 11
  • [8] Powered Ankle Exoskeletons: Existent Designs and Control Systems
    Weerasingha, A. H.
    Withanage, W. P. K.
    Pragnathilaka, A. D. K. H.
    Ranaweera, R. K. P. S.
    Gopura, R. A. R. C.
    ICAROB 2018: PROCEEDINGS OF THE 2018 INTERNATIONAL CONFERENCE ON ARTIFICIAL LIFE AND ROBOTICS, 2018, : 76 - 83
  • [9] Gait variability of outdoor vs treadmill walking with bilateral robotic ankle exoskeletons under proportional myoelectric control
    Hybart, Rachel
    Ferris, Daniel
    PLOS ONE, 2023, 18 (11):
  • [10] Walking Ankle Biomechanics of Individuals With Transtibial Amputations Using a Prescribed Prosthesis and a Portable Bionic Prosthesis Under Myoelectric Control
    Stafford, Nicole E.
    Gonzalez, Eddie B.
    Ferris, Daniel P.
    IEEE TRANSACTIONS ON NEURAL SYSTEMS AND REHABILITATION ENGINEERING, 2024, 32 : 3036 - 3047