Development and characterization of an interferometer for calorimeter-based absorbed dose to water measurements in a medical linear accelerator

被引:10
|
作者
Flores-Martinez, Everardo [1 ]
Malin, Martha J. [1 ]
DeWerd, Larry A. [1 ]
机构
[1] Univ Wisconsin, Dept Med Phys, Sch Med & Publ Hlth, Madison, WI 53705 USA
来源
REVIEW OF SCIENTIFIC INSTRUMENTS | 2016年 / 87卷 / 11期
关键词
HOLOGRAPHIC INTERFEROMETER; TRANSPARENT LIQUIDS; ELECTRON-BEAMS; RADIATION; DISTRIBUTIONS; PHOTON; RADIOTHERAPY; VALIDATION; DOSIMETRY;
D O I
10.1063/1.4967490
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
The quantity of relevance for external beam radiotherapy is absorbed dose to water (ADW). An interferometer was built, characterized, and tested to measure ADW within the dose range of interest for external beam radiotherapy using the temperature dependence of the refractive index of water. The interferometer was used to measure radiation-induced phase shifts of a laser beam passing through a (10 x 10 x 10) cm(3) water-filled glass phantom, irradiated with a 6 MV photon beam from a medical linear accelerator. The field size was (7 x 7) cm(2) and the dose was measured at a depth of 5 cm in the water phantom. The intensity of the interference pattern was measured with a photodiode and was used to calculate the time-dependent phase shift curve. The system was thermally insulated to achieve temperature drifts of less than 1.5 mK/min. Data were acquired 60 s before and after the irradiation. The radiation-induced phase shifts were calculated by taking the difference in the pre- and post-irradiation drifts extrapolated to the midpoint of the irradiation. For 200, 300, and 400 monitor units, the measured doses were 1.6 +/- 0.3, 2.6 +/- 0.3, and 3.1 +/- 0.3 Gy, respectively. Measurements agreed within the uncertainty with dose calculations performed with a treatment planning system. The estimated type-A, k = 1 uncertainty in the measured doses was 0.3 Gy which is an order of magnitude lower than previously published interferometer-based ADW measurements. Published by AIP Publishing.
引用
收藏
页数:8
相关论文
共 28 条
  • [21] Measuring the photon depth dose distribution produced by a medical linear accelerator in a water-equivalent radio-fluorogenic gel
    Sandwall, Peter A.
    Spitz, Henry B.
    Elson, Howard R.
    Lamba, Michael A. S.
    Connick, William B.
    Fenichel, Henry
    JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 2016, 307 (03) : 2505 - 2508
  • [22] Measuring the photon depth dose distribution produced by a medical linear accelerator in a water-equivalent radio-fluorogenic gel
    Peter A. Sandwall
    Henry B. Spitz
    Howard R. Elson
    Michael A. S. Lamba
    William B. Connick
    Henry Fenichel
    Journal of Radioanalytical and Nuclear Chemistry, 2016, 307 : 2505 - 2508
  • [23] Development of An Absorbed Dose to Water Primary Standard for HDR Ir-192 Brachytherapy Based On the Fricke Dosimetry System
    El Gamal, I.
    Cojocaru, C.
    Mainegra-Hing, E.
    Ross, C.
    McEwen, M.
    MEDICAL PHYSICS, 2013, 40 (06)
  • [24] Development of a dose-rate dosimeter using a silicon photodiode for a medical linear accelerator in a 10 MV flattening filter-free mode
    Yamaguchi, Satoshi
    Ariga, Hisanori
    Yoshioka, Kunihiro
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2024, 95 (05):
  • [25] COMPARISON OF CENTRAL AXIS DEPTH DOSE VALUES IN WATER AND TISSUE-EQUIVALENT LIQUID FOR ELECTRON-BEAMS FROM A MEDICAL LINEAR-ACCELERATOR
    BELL, JH
    WAGGENER, RG
    NYDEGGER, RR
    PHYSICS IN MEDICINE AND BIOLOGY, 1977, 22 (03): : 575 - 576
  • [26] A method of absorbed dose determination using vitamin B2 water for optical imaging of X-rays from high energy medical linear accelerators
    Toyonaga, Chihiro
    Yamamoto, Seiichi
    Yogo, Katsunori
    Okudaira, Kuniyasu
    Kawabata, Fumitaka
    Nakaya, Takayoshi
    Oguchi, Hiroshi
    RADIATION MEASUREMENTS, 2020, 131
  • [27] Response of CaSO4:Dy phosphor based TLD badge system to high energy electron beams from medical linear accelerator and estimation of whole body dose and skin dose
    Chatterjee, S.
    Bakshi, A. K.
    Kinhikar, R. A.
    Chourasiya, G.
    Kher, R. K.
    RADIATION MEASUREMENTS, 2009, 44 (03) : 257 - 262
  • [28] Dose distribution measurements using luminol water during irradiation of high-energy X-rays from medical linear accelerators (LINAC)
    Yamamoto, Seiichi
    Yamada, Koya
    Yabe, Takuya
    Hirano, Yoshiyuki
    Kataoka, Jun
    RADIATION PHYSICS AND CHEMISTRY, 2023, 208