Optimization and performance analysis of SERS-active suspended core photonic crystal fibers

被引:22
|
作者
Beffara, Flavien [1 ,2 ]
Humbert, Georges [2 ]
Auguste, Jean-Louis [2 ]
Perumal, Jayakumar [1 ]
Dinish, U. S. [1 ]
Olivo, Malini [1 ]
机构
[1] ASTAR, Lab Rio Opt Imaging, Singapore Bioimaging Consortium SBIC, Singapore, Singapore
[2] Limoges Univ, XLIM Res Inst, UMR 7252, CNRS, 123 AV A Thomas, F-87060 Limoges, France
来源
OPTICS EXPRESS | 2020年 / 28卷 / 16期
关键词
ENHANCED RAMAN-SCATTERING; SURFACE; SPECTROSCOPY; SUBSTRATE; SILVER; NANOPARTICLES; ASSEMBLIES; UNIFORM; FILMS;
D O I
10.1364/OE.393251
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
Recently, surface enhanced Raman spectroscopy (SERS)-active photonic crystal fiber (PCFs) probes have gained great interest for biosensing applications due to the tremendous advantages it has over the conventional planar substrate based SERS measurements, with improvements on the detection sensitivity and reliability in measurements. So far, two main approaches were employed to get the analyte molecule in the vicinity of nanoparticles (NPs) inside PCFs in order to achieve the SERS effect. In the first case, analyte and NPs are pre-mixed and injected inside the holes of the PCF prior to the measurement. In the second approach, controlled anchoring of the NPs inside the inner walls of the PCF was achieved prior to the incorporation of the analyte. Although many studies have been conducted using one configuration or the other, no clear trend is emerging on which one would be the best suited for optimizing the biosensing properties offered by SERS active-PCF. In this paper, we investigate the performances of both configurations along with their interplays with the core size of the PCF probe. We have fabricated several samples of a standard PCF design with different core sizes, and SERS measurements of a standard Raman-active molecule are realized in the same conditions for enabling direct comparisons of the SERS intensity and measurement reliabilities between each configuration, yielding clear directions on the optimization of the SERS-active PCF probe. We envision that this study will pave the way for next-generation clinical biosensors for body fluid analysis, as it exhibits high sensitivity and excellent reliability. (C) 2020 Optical Society of America under the terms of the OSA Open Access Publishing Agreement
引用
收藏
页码:23609 / 23619
页数:11
相关论文
共 50 条
  • [21] Development of highly reliable SERS-active photonic crystal fiber probe and its application in the detection of ovarian cancer biomarker in cyst fluid
    Beffara, Flavien
    Perumal, Jayakumar
    Mahyuddin, Aniza Puteri
    Choolani, Mahesh
    Khan, Saif A.
    Auguste, Jean-Louis
    Vedraine, Sylvain
    Humbert, Georges
    Dinish, U. S.
    Olivo, Malini
    JOURNAL OF BIOPHOTONICS, 2020, 13 (03)
  • [22] Numerical Investigation of the Photonic-Crystal Fibres with Suspended Core
    Pustelny, T.
    Grabka, M.
    ACTA PHYSICA POLONICA A, 2009, 116 (03) : 385 - 388
  • [23] Photonic-Crystal Fibres with Suspended Core - Numerical Analyses
    Pustelny, T.
    Grabka, M.
    ACTA PHYSICA POLONICA A, 2008, 114 (6A) : A115 - A120
  • [24] Visualizing the photonic band gap in hollow core photonic crystal fibers
    Couny, F
    Sabert, H
    Roberts, PJ
    Williams, DP
    Tomlinson, A
    Mangan, BJ
    Farr, L
    Knight, JC
    Birks, TA
    Russell, PS
    OPTICS EXPRESS, 2005, 13 (02): : 558 - 563
  • [25] Supercontinuum generation in heavy-metal oxide glass based suspended-core photonic crystal fibers
    Ghosh, A. N.
    Klimczak, M.
    Buczynski, R.
    Dudley, J. M.
    Sylvestre, T.
    JOURNAL OF THE OPTICAL SOCIETY OF AMERICA B-OPTICAL PHYSICS, 2018, 35 (09) : 2311 - 2316
  • [26] Toward A Highly Specific DNA Biosensor: PNA-Modified Suspended-Core Photonic Crystal Fibers
    Coscelli, Enrico
    Sozzi, Michele
    Poli, Federica
    Passaro, Davide
    Cucinotta, Annamaria
    Selleri, Stefano
    Corradini, Roberto
    Marchelli, Rosangela
    IEEE JOURNAL OF SELECTED TOPICS IN QUANTUM ELECTRONICS, 2010, 16 (04) : 967 - 972
  • [27] Supermode analysis of seven-core photonic quasi-crystal fibers
    李志全
    刘梦
    郝锐
    童凯
    王志斌
    Chinese Optics Letters, 2013, 11 (08) : 1 - 4
  • [28] Supermode analysis of seven-core photonic quasi-crystal fibers
    Li, Zhiquan
    Liu, Meng
    Hao, Rui
    Tong, Kai
    Wang, Zhibin
    CHINESE OPTICS LETTERS, 2013, 11 (08)
  • [29] Chalcogenide glass hollow core photonic crystal fibers
    Desevedavy, Frederic
    Renversez, Gilles
    Troles, Johann
    Houizot, Patrick
    Brilland, Laurent
    Vasilief, Ion
    Coulombier, Quentin
    Traynor, Nicholas
    Smektala, Frederic
    Adam, Jean-Luc
    OPTICAL MATERIALS, 2010, 32 (11) : 1532 - 1539
  • [30] Terahertz liquid crystal suspended core photonic crystal fiber polarization rotator
    Hagras, Esam A. A.
    Hameed, Mohamed Farhat O.
    Obayya, S. S. A.
    OPTICS AND LASER TECHNOLOGY, 2024, 174