Correlation of peripheral venous pressure and central venous pressure in kidney recipients

被引:32
|
作者
Hadimioglu, N [1 ]
Ertug, Z
Yegin, A
Sanli, S
Gurkan, A
Demirbas, A
机构
[1] Akdeniz Univ, Sch Med, Dept Anesthesiol & Intens Care Med, Antalya, Turkey
[2] Akdeniz Univ, Sch Med, Dept Surg, Antalya, Turkey
关键词
D O I
10.1016/j.transproceed.2005.12.057
中图分类号
R392 [医学免疫学]; Q939.91 [免疫学];
学科分类号
100102 ;
摘要
Background and objective. Previous studies in adults have demonstrated a clinically useful correlation between central venous pressure (CVP) and peripheral venous pressure (PVP). The current study prospectively compared CVP measurements from a central versus a peripheral catheter in kidney recipients during renal transplantation. Methods. With ethics committee approval and informed consent, 30 consecutive kidney recipients were included in the study. We excluded patients who had significant valvular disease or clinically apparent left ventricular failure. For each of 30 patients, CVP and PVP were measured on five different occasions. The pressure tubing of the transducer system was connected to the distal lumen of the central or to the peripheral venous catheter for measurements following induction of anesthesia, after induction, 1 hour after induction, reperfusion of the kidney, and the end of the operation, yielding 150 hemodynamic data points. Each hemodynamic measurement included heart rate, mean arterial pressure, mean CVP, and mean PVP determined at end-expiration. Results. The mean PVP was 13.5 +/- 1.8 mm Hg and the mean CVP was 11.0 +/- 1.5 mm Hg during surgery. The mean difference was 2.5 +/- 0.5 (P < .01). Repeated-measures analysis of variance indicated a highly significant relationship between PVP and CVP (P < .01) with a Pearson correlation coefficient of 0.97. Conclusion. Under the conditions of this study, PVP showed a consistently high agreement with CVP in the perioperative period among patients without significant cardiac dysfunction.
引用
收藏
页码:440 / 442
页数:3
相关论文
共 50 条
  • [41] Effect of body temperature on peripheral venous pressure measurements and its agreement with central venous pressure in neurosurgical patients
    Sahin, A.
    Salman, M. A.
    Salman, A. E.
    Aypar, U.
    EUROPEAN JOURNAL OF ANAESTHESIOLOGY, 2004, 21 : 99 - 99
  • [42] Effect of body temperature on peripheral venous pressure measurements and it's agreement with central venous pressure in neurosurgical patients
    Sahin, A
    Salman, MA
    Salman, AE
    Aypar, U
    JOURNAL OF NEUROSURGICAL ANESTHESIOLOGY, 2005, 17 (02) : 91 - 96
  • [43] RELATIONSHIP BETWEEN PERIPHERAL AND CENTRAL VENOUS-PRESSURE GRADIENT AND VENOUS FLOW VELOCITY
    WATANABE, R
    MATSUMOT.M
    KAWANAKA, T
    YANAGIZA.T
    FUJIWARA, H
    WADA, T
    HONDA, T
    SOMA, T
    JAPANESE CIRCULATION JOURNAL-ENGLISH EDITION, 1973, 37 (06): : 584 - 585
  • [44] Peripheral venous pressure waveform
    Wardhan, Richa
    Shelley, Kirk
    CURRENT OPINION IN ANESTHESIOLOGY, 2009, 22 (06) : 814 - 821
  • [45] Iliac venous pressure estimates central venous pressure after laparotomy
    Boone, Brian A.
    Kirk, Katherine A.
    Tucker, Nikia
    Gunn, Scott
    Forsythe, Raquel
    JOURNAL OF SURGICAL RESEARCH, 2014, 191 (01) : 203 - 207
  • [46] Evaluation of peripheral and central venous pressure in awake dogs and cats
    Chow, Rosalind S.
    Kass, Phillip H.
    Haskins, Steve C.
    AMERICAN JOURNAL OF VETERINARY RESEARCH, 2006, 67 (12) : 1987 - 1991
  • [47] MEASUREMENT OF CENTRAL VENOUS PRESSURE
    STEWART, KS
    LANCET, 1971, 1 (7702): : 756 - &
  • [48] Central venous pressure monitoring
    Ball, C.
    Westhorpe, R. N.
    ANAESTHESIA AND INTENSIVE CARE, 2009, 37 (05) : 689 - 689
  • [49] Central venous pressure in space
    Buckey, JC
    Gaffney, FA
    Lane, LD
    Levine, BD
    Watenpaugh, DE
    Wright, SJ
    Yancy, CW
    Meyer, DM
    Blomqvist, CG
    JOURNAL OF APPLIED PHYSIOLOGY, 1996, 81 (01) : 19 - 25
  • [50] Central venous pressure monitoring
    Magder, Sheldon
    CURRENT OPINION IN CRITICAL CARE, 2006, 12 (03) : 219 - 227