Psychophysical evaluation of the image quality of a dynamic flat-panel digital X-ray image detector using the threshold contrast detail detectability (TCDD) technique

被引:0
|
作者
Davies, AG [1 ]
Cowen, AR [1 ]
Bruijns, TJ [1 ]
机构
[1] Univ Leeds, Gen Infirm, Leeds LS1 3EX, W Yorkshire, England
关键词
D O I
10.1117/12.349639
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
We are currently in an era of active development of the digital X-ray imaging detectors that will serve the radiological communities in the new millennium. The rigorous comparative physical evaluations of such devices are therefore becoming increasingly important from both the technical and clinical perspectives. The authors have been actively involved in the evaluation of a clinical demonstration version of a flat-panel dynamic digital X-ray image detector (or FDXD). Results of objective physical evaluation of this device have been presented elsewhere at this conference. The imaging performance of FDXD under radiographic exposure conditions have been previously reported, and in this paper a psychophysical evaluation of the FDXD detector operating under continuous fluoroscopic conditions is presented. The evaluation technique employed was the threshold contrast detail detectability (TCDD) technique, which enables image quality to be measured on devices operating in the clinical environment. This approach addresses image quality in the context of both the image acquisition and display processes, and uses human observers to measure performance. The Leeds test objects TO[10] and TO[10+] were used to obtain comparative measurements of performance on the FDXD and two digital spot fluorography (DSF) systems, one utilising a Plumbicon camera and the other a state of the art CCD camera. Measurements were taken at a range of detector entrance exposure rates, namely 6, 12, 25 and 50 mu R/s. In order to facilitate comparisons between the systems, all fluoroscopic image processing such as noise reduction algorithms, were disabled during the experiments. At the highest dose rate FDXD significantly outperformed the DSF comparison systems in the TCDD comparisons. At 25 and 12 mu R/s all three systems performed in an equivalent manner and at the lowest exposure rate FDXD was inferior to the two DSF systems. At standard fluoroscopic exposures, FDXD performed in an equivalent manner to the DSF systems for the TCDD comparisons. This would suggest that FDXD would therefore perform adequately in a clinical fluoroscopic environment and our initial clinical experiences support this. Noise reduction processing of the fluoroscopic data acquired on FDXD was also found to further improve TCDD performance for FDXD. FDXD therefore combines acceptable fluoroscopic performance with excellent radiographic (snap shot) imaging fidelity, allowing the possibility of a universal x-ray detector to be developed, based on FDXD's technology. It is also envisaged that fluoroscopic performance will be improved by the development of digital image enhancement techniques specifically tailored to the characteristics of the FDXD detector.
引用
收藏
页码:170 / 179
页数:10
相关论文
共 50 条
  • [1] Threshold contrast detail detectability measurement of the fluoroscopic image quality of a dynamic solid-state digital x-ray image detector
    Davies, AG
    Cowen, AR
    Kengyelics, SM
    Bury, RF
    Bruijns, TJ
    MEDICAL PHYSICS, 2001, 28 (01) : 11 - 15
  • [2] Quantitative image quality evaluation of pixel-binning in a flat-panel detector for x-ray fluoroscopy
    Srinivas, Y
    Wilson, DL
    MEDICAL PHYSICS, 2004, 31 (01) : 131 - 141
  • [3] Image quality evaluation of a selenium-based flat-panel digital x-ray detector system based on animal studies
    Yamada, S
    Umazaki, H
    Takahashi, A
    Honda, M
    Shiraishi, K
    Rudin, S
    Bednarek, DR
    Yang, CYJ
    Wang, Z
    Gopal, A
    MEDICAL IMAGING 2000: PHYSICS OF MEDICAL IMAGING, 2000, 3977 : 429 - 436
  • [4] Dynamic Chest X-Ray Using a Flat-Panel Detector System: Technique and Applications
    Hata, Akinori
    Yamada, Yoshitake
    Tanaka, Rie
    Nishino, Mizuki
    Hida, Tomoyuki
    Hino, Takuya
    Ueyama, Masako
    Yanagawa, Masahiro
    Kamitani, Takeshi
    Kurosaki, Atsuko
    Sanada, Shigeru
    Jinzaki, Masahiro
    Ishigami, Kousei
    Tomiyama, Noriyuki
    Honda, Hiroshi
    Kudoh, Shoji
    Hatabu, Hiroto
    KOREAN JOURNAL OF RADIOLOGY, 2021, 22 (04) : 634 - 651
  • [5] Image quality evaluation of flat panel detector binning in X-ray fluoroscopy
    Srinivas, Y
    Wilson, DL
    2002 IEEE INTERNATIONAL SYMPOSIUM ON BIOMEDICAL IMAGING, PROCEEDINGS, 2002, : 177 - 180
  • [6] Image quality evaluation of flat panel and image intensifier digital magnification in x-ray fluoroscopy
    Srinivas, Y
    Wilson, DL
    MEDICAL PHYSICS, 2002, 29 (07) : 1611 - 1621
  • [7] Evaluation of image lag in a flat-panel, detector-equipped cardiovascular X-ray machine using a newly developed dynamic phantom
    Sato, Hisaya
    Kondo, Keisuke
    Kato, Kyoichi
    Nakazawa, Yasuo
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2015, 16 (02): : 366 - 375
  • [8] Dual-energy cardiac imaging: an image quality and dose comparison for a flat-panel detector and x-ray image intensifier
    Ducote, Justin L.
    Xu, Tong
    Molloi, Sabee
    PHYSICS IN MEDICINE AND BIOLOGY, 2007, 52 (01): : 183 - 196
  • [9] Experimental evaluation of a-Se flat-panel X-ray detector for digital radiography
    Kim, JY
    Park, JK
    Choi, JY
    Cha, BY
    Kang, SS
    An, SH
    Nam, SH
    Choi, HK
    2004 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-7, 2004, : 4048 - 4052
  • [10] Experimental evaluation of a-Se flat-panel X-ray detector for digital radiography
    Choi, JY
    Park, JK
    Lee, DG
    Kang, SS
    Nam, SH
    NEW APPLICATIONS FOR WIDE-BANDGAP SEMICONDUCTORS, 2003, 764 : 265 - 270