Accuracy of contrast-enhanced magnetic resonance angiography in chronic thromboembolic disease

被引:22
|
作者
Wolff, K
Bergin, CJ
King, MA
Ghadishah, E
Sung, DW
Clopton, P
Bookstein, JJ
Auger, WR
Moser, KM
机构
[1] UNIV CALIF SAN DIEGO,MED CTR,DEPT RADIOL 8756,SAN DIEGO,CA 92103
[2] UNIV CALIF SAN DIEGO,MED CTR,DEPT PULM MED,SAN DIEGO,CA 92103
[3] UNIV CALIF SAN DIEGO,MED CTR,DEPT BIOSTAT,SAN DIEGO,CA 92103
关键词
chronic pulmonary thromboembolism; magnetic resonance angiography; conventional angiography;
D O I
10.1016/S1076-6332(96)80325-4
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Rationale and Objectives. We evaluated the accuracy of contrast-enhanced magnetic resonance (MR) angiography in demonstrating the findings of chronic pulmonary thromboembolism (CPTE) compared with conventional pulmonary angiography. Methods. We examined 18 patients with CPTE proved by conventional pulmonary angiography and 16 healthy control patients. T1-weighted and single-breathhold, two-dimensional multiplanar spoiled gradient-recalled pulmonary images were obtained after injection of gadopentetate dimeglumine. Images were interpreted independently by two radiologists. Results. All patients with CPTE were identified on MR angiography images by both readers. Sensitivity and specificity for MR angiography in diagnosing abnormal segments were 76% and 95% for reader 1 and 68% and 93% for reader 2, respectively. Sensitivity and specificity for MR angiography in depicting abnormal lobes were 83% and 96% for reader 1 and 82% and 93% for reader 2, respectively. Interobserver agreement was high; kappas for abnormal segments and abnormal lobes were .72 and .84, respectively. The T1-weighted spin-echo images demonstrated a mosaic signal intensity pattern in all patients with CPTE. Conclusion. Contrast-enhanced MR angiography accurately depicts abnormal segments and lobes in occlusive vascular disease and clearly distinguishes between patients with CPTE and those with healthy lungs.
引用
收藏
页码:10 / 17
页数:8
相关论文
共 50 条
  • [41] Accuracy and utility of three-dimensional contrast-enhanced magnetic resonance angiography in planning carotid stenting - Discussion
    Jordan, William
    Timaran, Carlos
    JOURNAL OF VASCULAR SURGERY, 2007, 46 (02) : 263 - 264
  • [42] The future of contrast-enhanced magnetic resonance angiography -: Are blood pool agents needed?
    Mühler, A
    INVESTIGATIVE RADIOLOGY, 1998, 33 (09) : 709 - 714
  • [43] Contrast-Enhanced Magnetic Resonance Angiography in the Early Period After Kidney Transplantation
    Hwang, J. K.
    Chun, H. J.
    Kim, J. M.
    Kwon, K. H.
    Kim, Y. K.
    Kim, S. D.
    Park, S. C.
    Choi, B. S.
    Kim, J. I.
    Yang, C. W.
    Kim, Y. S.
    Moon, I. S.
    TRANSPLANTATION PROCEEDINGS, 2013, 45 (08) : 2925 - 2930
  • [44] Contrast-enhanced magnetic resonance angiography of the iliac arteries: Optimization by injection simulation
    Schmidt, MA
    Britten, AJ
    Tomlinson, MA
    Vig, S
    Powell, S
    Cleminson, S
    Kerr, E
    Blundell, J
    Heron, CW
    MAGNETIC RESONANCE IN MEDICINE, 2001, 46 (02) : 365 - 373
  • [45] Dynamic contrast-enhanced magnetic resonance angiography of vascular malformations in pediatric patients
    Mukundan, Srinivasan
    Fuchs, Herbert
    Alexander, Michael J.
    Grant, Gerald A.
    JOURNAL OF NEUROSURGERY, 2007, 107 (03) : 228 - 231
  • [46] Comparison of 1.5 and 3.0 T for Contrast-Enhanced Pulmonary Magnetic Resonance Angiography
    Londy, Frank Joseph
    Lowe, Suzan
    Stein, Paul D.
    Weg, John G.
    Eisner, Robert L.
    Leeper, Kenneth V.
    Woodard, Pamela K.
    Sostman, H. Dirk
    Jablonski, Kathleen A.
    Fowler, Sarah E.
    Hales, Charles A.
    Hull, Russell D.
    Gottschalk, Alexander
    Naidich, David P.
    Chenevert, Thomas L.
    CLINICAL AND APPLIED THROMBOSIS-HEMOSTASIS, 2012, 18 (02) : 134 - 139
  • [47] Standardized volume-rendering of contrast-enhanced renal magnetic resonance angiography
    Smedby, Ö
    Öberg, R
    Åsberg, B
    Stenström, H
    Eriksson, P
    ACTA RADIOLOGICA, 2005, 46 (05) : 497 - 504
  • [48] Three-dimensional contrast-enhanced magnetic resonance angiography of the thoracic vasculature
    Leung, DA
    Debatin, JF
    EUROPEAN RADIOLOGY, 1997, 7 (07) : 981 - 989
  • [49] Contrast-enhanced magnetic resonance angiography of the cervical vessels - Experience with 422 patients
    Phan, T
    Huston, J
    Bernstein, MA
    Riederer, SJ
    Brown, RD
    STROKE, 2001, 32 (10) : 2282 - 2286
  • [50] Contrast-enhanced magnetic resonance angiography of persistent fifth aortic arch in children
    Zhong, Yumin
    Jaffe, Richard B.
    Zhu, Ming
    Sun, Aimin
    Li, Yuhua
    Gao, Wei
    PEDIATRIC RADIOLOGY, 2007, 37 (03) : 256 - 263