Accuracy of contrast-enhanced magnetic resonance angiography in chronic thromboembolic disease

被引:22
|
作者
Wolff, K
Bergin, CJ
King, MA
Ghadishah, E
Sung, DW
Clopton, P
Bookstein, JJ
Auger, WR
Moser, KM
机构
[1] UNIV CALIF SAN DIEGO,MED CTR,DEPT RADIOL 8756,SAN DIEGO,CA 92103
[2] UNIV CALIF SAN DIEGO,MED CTR,DEPT PULM MED,SAN DIEGO,CA 92103
[3] UNIV CALIF SAN DIEGO,MED CTR,DEPT BIOSTAT,SAN DIEGO,CA 92103
关键词
chronic pulmonary thromboembolism; magnetic resonance angiography; conventional angiography;
D O I
10.1016/S1076-6332(96)80325-4
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Rationale and Objectives. We evaluated the accuracy of contrast-enhanced magnetic resonance (MR) angiography in demonstrating the findings of chronic pulmonary thromboembolism (CPTE) compared with conventional pulmonary angiography. Methods. We examined 18 patients with CPTE proved by conventional pulmonary angiography and 16 healthy control patients. T1-weighted and single-breathhold, two-dimensional multiplanar spoiled gradient-recalled pulmonary images were obtained after injection of gadopentetate dimeglumine. Images were interpreted independently by two radiologists. Results. All patients with CPTE were identified on MR angiography images by both readers. Sensitivity and specificity for MR angiography in diagnosing abnormal segments were 76% and 95% for reader 1 and 68% and 93% for reader 2, respectively. Sensitivity and specificity for MR angiography in depicting abnormal lobes were 83% and 96% for reader 1 and 82% and 93% for reader 2, respectively. Interobserver agreement was high; kappas for abnormal segments and abnormal lobes were .72 and .84, respectively. The T1-weighted spin-echo images demonstrated a mosaic signal intensity pattern in all patients with CPTE. Conclusion. Contrast-enhanced MR angiography accurately depicts abnormal segments and lobes in occlusive vascular disease and clearly distinguishes between patients with CPTE and those with healthy lungs.
引用
收藏
页码:10 / 17
页数:8
相关论文
共 50 条
  • [1] Contrast-Enhanced Magnetic Resonance Angiography
    Vasile, Julie V.
    Newman, Tiffany M.
    Prince, Martin R.
    Rusch, David G.
    Greenspun, David T.
    Allen, Robert J.
    Levine, Joshua L.
    CLINICS IN PLASTIC SURGERY, 2011, 38 (02) : 263 - +
  • [2] Contrast-Enhanced Magnetic Resonance Angiography
    Chandra, Tushar
    Pukenas, Bryan
    Mohan, Suyash
    Melhem, Elias
    MAGNETIC RESONANCE IMAGING CLINICS OF NORTH AMERICA, 2012, 20 (04) : 687 - +
  • [3] Contrast-enhanced magnetic resonance angiography
    Roditi, G
    BRITISH JOURNAL OF SURGERY, 2002, 89 (07) : 817 - 820
  • [4] Contrast-enhanced magnetic resonance angiography in congenital heart disease
    Marin Rodriguez, C.
    Maroto Alvaro, E.
    Sanchez Alegre, M. L.
    Ruiz Martin, Y.
    Delgado Carrasco, J.
    RADIOLOGIA, 2009, 51 (03): : 261 - 272
  • [5] CONTRAST-ENHANCED MAGNETIC-RESONANCE ANGIOGRAPHY
    VOGL, TJ
    HOFFMANN, Y
    MUHLER, A
    FELIX, A
    RADIOLOGE, 1994, 34 (08): : 423 - 429
  • [6] Diagnostic Accuracy of Contrast-Enhanced Magnetic Resonance Angiography and Duplex Ultrasound in Patients With Peripheral Vascular Disease
    Alicia Bueno, Dra
    Acin, Francisco
    Cristina Canibano, Dra
    Fernandez-Casado, Jose L.
    Castillo, E.
    VASCULAR AND ENDOVASCULAR SURGERY, 2010, 44 (07) : 576 - 585
  • [7] Transport of contrast agents in contrast-enhanced magnetic resonance angiography
    Jou, LD
    Rapp, J
    Saloner, D
    MAGNETIC RESONANCE IMAGING, 2004, 22 (04) : 495 - 504
  • [8] Contrast-enhanced magnetic resonance angiography carotid arteries
    U-King-Im, J
    Trivedi, R
    Gillard, JH
    STROKE, 2003, 34 (05) : E15 - E15
  • [9] Recent advances in contrast-enhanced magnetic resonance angiography
    Meaney, James F. M.
    Goyen, Mathias
    EUROPEAN RADIOLOGY, 2007, 17 : B2 - B6
  • [10] Three-dimensional contrast-enhanced magnetic resonance angiography in a patient with chronic thromboembolic pulmonary hypertension before and after thromboendarterectomy
    Kreitner, KF
    Mayer, E
    Voigtlaender, T
    Thelen, M
    Oelert, H
    CIRCULATION, 1999, 99 (08) : 1101 - 1101