Label free polyaniline based impedimetric biosensor for detection of E. coli O157:H7 Bacteria

被引:98
|
作者
Chowdhury, Ankan Dutta [1 ]
De, Amitabha [1 ]
Chaudhuri, Chirosree Roy [2 ]
Bandyopadhyay, Krishnan [3 ]
Sen, Pintu [4 ]
机构
[1] Saha Inst Nucl Phys, Div Chem Sci, Kolkata 700064, W Bengal, India
[2] Bengal Engn & Sci Univ Shibpur, Dept Elect & Telecommun Engn, Sibpur, W Bengal, India
[3] Bengal Engn & Sci Univ Shibpur, Sch Mat Sci & Engn, Sibpur, W Bengal, India
[4] Ctr Variable Energy Cyclotron, Dept Phys, Kolkata 700064, W Bengal, India
来源
关键词
Antibody-antigen binding; Biosensor; Impedimetric sensor; Polyaniline; Bacteria detection; ESCHERICHIA-COLI; ELECTROCHEMICAL DETECTION; NANOPARTICLE; O157-H7; IMMUNOSENSOR; CELLS;
D O I
10.1016/j.snb.2012.06.004
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A new and simple method for label free, rapid and inexpensive impedimetric sensing of Escherichia coli O157:H7 (a highly infectious and potentially fatal food and water borne pathogen) using antibody-antigen binding method based on covalently linked antibody on a conducting Polyaniline (PANI) film surface is reported. Electrochemical impedance spectroscopy (EIS) was used to test the sensitivity and effectiveness of the sensor electrode by measuring the change in impedance values of electrodes before and after incubation with different concentrations of bacteria. An equivalent electrical circuit model has also been proposed to explain the sensing mechanism. As small concentration as 10(2) CFU mL(-1) of E. coli O157:H7 were successfully detected on the Au/PANI/Glu/antibody sensor with the upper detection limit of 10(7) CFU mL(-1). The specificity of the sensor has been tested by comparing with two other strains of similar bacteria and found to be satisfactory. The mechanism of the detection is very simple and rapid, giving it a major advantage over DNA based techniques and other secondary antibody based labeled methods. (C) 2012 Elsevier B.V. All rights reserved.
引用
收藏
页码:916 / 923
页数:8
相关论文
共 50 条
  • [1] Validation of the ANSR® E. coli O157:H7 Method for Detection of E. coli O157:H7
    Viator, Ryan
    Alles, Susan
    Le, Quynh-Nhi
    Hosking, Edan
    Meister, Evan
    Pinkava, Lisa
    Tovar, Eric
    Mozola, Mark
    Rice, Jennifer
    JOURNAL OF AOAC INTERNATIONAL, 2016, 99 (03) : 705 - 716
  • [2] Dendrimeric biosensor for detection of E. coli O157:H7 in diet
    Shende, Pravin
    Kasture, Pooja
    BIOINTERFACE RESEARCH IN APPLIED CHEMISTRY, 2020, 10 (02): : 5128 - 5131
  • [3] E. coli O157: H7
    Fernandez, Treor Francis
    VETERINARY WORLD, 2008, 1 (03) : 83 - 87
  • [4] Label-free amperometric biosensor for Escherichia coli O157:H7 detection
    Dhull, Nidhi
    Kaur, Gurpreet
    Jain, Prateek
    Mishra, Priyanka
    Singh, Divya
    Ganju, Lilly
    Gupta, Vinay
    Tomar, Monika
    APPLIED SURFACE SCIENCE, 2019, 495
  • [5] A micromachined impedance biosensor for accurate and rapid detection of E. coli O157:H7
    Dastider, Shibajyoti Ghosh
    Barizuddin, Syed
    Dweik, Majed
    Almasri, Mahmoud
    RSC ADVANCES, 2013, 3 (48): : 26297 - 26306
  • [6] Outbreak:: E. coli O157:H7
    Todd, Betsy
    AMERICAN JOURNAL OF NURSING, 2007, 107 (02) : 29 - 30
  • [7] Novel Biosensor Based on Electrospun Nanofiber and Magnetic Nanoparticles for the Detection of E. coli O157:H7
    Luo, Yilun
    Nartker, Steven
    Wiederoder, Michael
    Miller, Hanna
    Hochhalter, David
    Drzal, Lawrence T.
    Alocilja, Evangelyn C.
    IEEE TRANSACTIONS ON NANOTECHNOLOGY, 2012, 11 (04) : 676 - 681
  • [8] Performance of the ImmunoCard STAT!: E. coli O157:H7 test for detection of Escherichia coli O157:H7 in stools
    Mackenzie, A
    Orrbine, E
    Hyde, L
    Benoit, M
    Chan, F
    Park, C
    Alverson, J
    Lembke, A
    Hoban, D
    Kennedy, W
    JOURNAL OF CLINICAL MICROBIOLOGY, 2000, 38 (05) : 1866 - 1868
  • [9] Graphene-interfaced electrical biosensor for label-free and sensitive detection of foodborne pathogenic E. coli O157:H7
    Pandey, Ashish
    Gurbuz, Yasar
    Ozguz, Volkan
    Niazi, Javed H.
    Qureshi, Anjum
    BIOSENSORS & BIOELECTRONICS, 2017, 91 : 225 - 231
  • [10] An impedimetric biosensor for E. coli O157:H7 based on the use of self-assembled gold nanoparticles and protein G
    Donghai Lin
    Rajesh G. Pillai
    William Edward Lee
    Abebaw B. Jemere
    Microchimica Acta, 2019, 186