Evaluation and correction of injection order effects in LC-MS/MS based targeted metabolomics

被引:5
|
作者
Yue, Yang [1 ]
Bao, Xun [1 ]
Jiang, Jun [1 ]
Li, Jing [1 ]
机构
[1] Wayne State Univ Sch Med, Karmanos Canc Inst, Detroit, MI 48201 USA
关键词
LC-MS/MS based targeted metabolomics; Ion-pair liquid chromatography; Reversed-phase liquid chromatography; Hydrophilic interaction liquid chromatography (HILIC); Injection order effect; Batch effect; SPECTROMETRY-BASED METABOLOMICS; IONIZATION-MASS-SPECTROMETRY; QUALITY-CONTROL SAMPLES; ELECTROSPRAY-IONIZATION; CHROMATOGRAPHY; BATCH; SYSTEMS; SUPPRESSION; SEPARATION; DILUTION;
D O I
10.1016/j.jchromb.2022.123513
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
For large-scale and long-term metabolomics studies that involve a large batch or multiple batches of analyses, batch effects cause nonbiological systematic biases that may lead to false positive or false negative findings. Quantitative monitoring and correction of batch effects is critical to the development of reproducible and robust metabolomics platforms either for untargeted or targeted analyses. To achieve sufficient retention and separation of a broad range of metabolites with diverse chemical structures and physicochemical properties, LC-MS/MS based targeted metabolomics often involves 3 complemented chromatographic separation methods, including reversed-phase liquid chromatography (RP-LC), hydrophilic interaction liquid chromatography (HILIC), and ion-pair liquid chromatography (IP-LC). The purpose of this study is to quantitatively evaluate intra-batch variations or injection order effects of the RP-LC, HILIC, and IP-LC methods for targeted metabolomics analyses, and develop strategies to minimize intra-batch variations and correct injection order effects for problematic metabolites. Both RP-LC and HILIC methods exhibit robust intra-batch reproducibility in 0.2 mu M standard mix QC, with similar to 96 % of the measured metabolites showing acceptable intra-batch variations (<20 %); whereas, the intrabatch reproducibility for some metabolites in cell matrix QC may be compromised due to stability issue, suboptimal chromatographic retention, and/or matrix effects causing ionization suppression and/or retention instability. The IP-LC method exhibits significant injection order effects, which could be effectively corrected by the developed exponential models of signal drift trends as a function of injection order for individual targeted metabolites.
引用
收藏
页数:9
相关论文
共 50 条
  • [31] Integrated LC-MS and GC-MS-Based Metabolomics Reveal the Effects of Plant Competition on the Rye Metabolome
    Hazrati, Hossein
    Kudsk, Per
    Ding, Ling
    Uthe, Henriette
    Fomsgaard, Inge S.
    JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY, 2022, 70 (09) : 3056 - 3066
  • [32] Analytical strategies for LC-MS-based targeted metabolomics
    Lu, Wenyun
    Bennett, Bryson D.
    Rabinowitz, Joshua D.
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2008, 871 (02): : 236 - 242
  • [33] Improving the characterization of asthma by LC-MS metabolomics
    不详
    BIOANALYSIS, 2011, 3 (11) : 1179 - 1179
  • [34] Chemical Isotope Labeling LC-MS for Metabolomics
    Zhao, Shuang
    Li, Liang
    CANCER METABOLOMICS: METHODS AND APPLICATIONS, 2021, 1280 : 1 - 18
  • [35] Quantitative electrospray LC-MS and LC-MS/MS in biomedicine
    Carrascal, M
    Schneider, K
    Calaf, RE
    van Leeuwen, S
    Canosa, D
    Gelpí, E
    Abian, J
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 1998, 17 (6-7) : 1129 - 1138
  • [36] Integration of GC-MS and LC-MS for untargeted metabolomics profiling
    Zeki, Ozge Cansin
    Eylem, Cemil Can
    Recber, Tuba
    Kir, Sedef
    Nemutlu, Emirhan
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2020, 190
  • [37] Targeted Determination of Tissue Energy Status by LC-MS/MS
    Fu, Xiaorong
    Deja, Stanislaw
    Kucejova, Blanka
    Duarte, Joao A. G.
    McDonald, Jeffrey G.
    Burgess, Shawn C.
    ANALYTICAL CHEMISTRY, 2019, 91 (09) : 5881 - 5887
  • [38] Comparison of Flow Injection-MS/MS and LC-MS/MS for the Determination of Ochratoxin A
    Zhang, Kai
    TOXINS, 2021, 13 (08)
  • [39] Non-targeted Metabolomics Analysis Based on LC-MS to Assess the Effects of Different Cold Exposure Times on Piglets
    Chen, Yong
    Ji, Hong
    Guo, Jingru
    Chen, Yan
    Li, Wenjie
    Wang, Shengping
    Zhen, Li
    FRONTIERS IN PHYSIOLOGY, 2022, 13
  • [40] LC-MS based metabolomics and chemometrics study of the toxic effects of copper on Saccharomyces cerevisiae
    Farres, Mireia
    Pina, Benjami
    Tauler, Roma
    METALLOMICS, 2016, 8 (08) : 790 - 798