Precision of coaxial needle placement in computed tomography-guided transthoracic needle biopsy

被引:1
|
作者
Huang, Rui [1 ]
Jiang, Nan-Chuan [1 ]
Lu, Hao-Hao [1 ]
Wang, Yu-Hui [1 ]
Li, Hui [1 ]
Shi, He-Shui [1 ]
Han, Ping [1 ]
机构
[1] Huazhong Univ Sci & Technol, Tongji Med Coll, Union Hosp, Dept Radiol, Wuhan 430022, Hubei, Peoples R China
关键词
biopsy; computed tomography; thorax; audit; LUNG-BIOPSY; CORE BIOPSY; DIAGNOSTIC-ACCURACY; PULMONARY-LESIONS; CT; CANCER; HEMORRHAGE; NODULES; ARTERY; CHEST;
D O I
10.3892/etm.2013.1283
中图分类号
R-3 [医学研究方法]; R3 [基础医学];
学科分类号
1001 ;
摘要
In the present study, a set of self-designed measurement protocols for the precision of coaxial needle placement (PCNP) was proposed and applied in a computed tomography (CT)-guided transthoracic needle biopsy (TNB) audit of an interventional radiologist to determine if the PCNP was commensurate with the experience of the operator. A total of 102 patients (98 with lung lesions and four with mediastinum lesions) consented to be subjected to CT-guided TNB performed by staff interventional radiologists. The patients were divided into two groups based on appointment date. Group A consisted of the first 51 patients and group B comprised of the latter 51 patients. A set of self-designed measurement protocols for PCNP was proposed, and the PCNP was classified into four grades, from grade 1 (most accurate) to grade 4 (least accurate). PCNPs were independently measured by three staff radiologists who were blind to the grouping. The anatomical features of the lesions were also analyzed between the two groups. A significant difference in the PCNP gained after the first needle placement was identified between the two groups (P=0.003, two-tailed). The number of patients in group B with grade I PCNP (51.0%) was significantly higher than that in group A (21.6%) (P<0.05). The number of patients in group B with grade III PCNP (11.8%) was significantly lower than that in group A (29.4%, P<0.05). The PCNP was observed to be commensurate with the experience of the operator and should be considered as a routine audit index in CT guided TNB.
引用
收藏
页码:1307 / 1311
页数:5
相关论文
共 50 条
  • [41] Computed tomography-guided core needle biopsy versus incisional biopsy in diagnosing musculoskeletal lesions
    Kiatisevi, Piya
    Thanakit, Voranuch
    Sukunthanak, Bhasanan
    Boonthatip, Mayura
    Bumrungchart, Saraporn
    Witoonchart, Kiat
    [J]. JOURNAL OF ORTHOPAEDIC SURGERY, 2013, 21 (02): : 204 - 208
  • [42] The diagnostic value of ultrasound-guided percutaneous transthoracic core-needle biopsy versus computed tomography-guided biopsy in peripheral intrathoracic lesions
    Wafaa S. El-Shimy
    Fawzy A. El-Emery
    Ayman H. Abd El-Zaher
    Amr M. El-Badry
    Dalia E. El-Sharawy
    [J]. Egyptian Journal of Bronchology, 2016, 10 (1) : 12 - 19
  • [43] Computed tomography-guided needle biopsies in pediatric oncology
    Guimaraes, AC
    Chapchap, P
    de Camargo, B
    Chojniak, R
    [J]. JOURNAL OF PEDIATRIC SURGERY, 2003, 38 (07) : 1066 - 1068
  • [44] Air embolism detected during computed tomography fluoroscopically guided transthoracic needle biopsy
    Hirasawa, Satoshi
    Hirasawa, Hiromi
    Taketomi-Takahashi, Ayako
    Morita, Hideo
    Tsushima, Yoshito
    Amanuma, Makoto
    Endo, Keigo
    [J]. CARDIOVASCULAR AND INTERVENTIONAL RADIOLOGY, 2008, 31 (01) : 219 - 221
  • [45] Initial experience with real-time hybrid single-photon emission computed tomography/computed tomography-guided percutaneous transthoracic needle biopsy
    Hua, Qian
    Zhu, Xiangyun
    Zhang, Lei
    Zhao, Yanjun
    Tang, Ping
    Ni, Jianming
    [J]. NUCLEAR MEDICINE COMMUNICATIONS, 2017, 38 (06) : 556 - 560
  • [46] Air Embolism Detected During Computed Tomography Fluoroscopically Guided Transthoracic Needle Biopsy
    Satoshi Hirasawa
    Hiromi Hirasawa
    Ayako Taketomi-Takahashi
    Hideo Morita
    Yoshito Tsushima
    Makoto Amanuma
    Keigo Endo
    [J]. CardioVascular and Interventional Radiology, 2008, 31 : 219 - 221
  • [47] A Novel Laser Angle Selection System for Computed Tomography-Guided Percutaneous Transthoracic Needle Biopsies
    Xu, Huiting
    Zhao, Yanjun
    Yuan, Jiaqi
    Li, Wei
    Ni, Jianming
    [J]. CANADIAN ASSOCIATION OF RADIOLOGISTS JOURNAL-JOURNAL DE L ASSOCIATION CANADIENNE DES RADIOLOGISTES, 2023, 74 (02): : 455 - 461
  • [48] Using multistep approach technique to overcome the limitation of conventional sequential computed tomography-guided percutaneous transthoracic fine needle biopsy
    Park, Dong Il
    Jung, Sung Soo
    Park, Hee Sun
    Lee, Jeong Eun
    Chung, Chae Uk
    Kim, Ju Ock
    [J]. EUROPEAN RESPIRATORY JOURNAL, 2017, 50
  • [49] Percutaneous needle biopsy of mediastinal masses using a computed tomography-guided extrapleural approach
    Grant, TH
    Stull, MA
    Kandallu, K
    Chambliss, JF
    [J]. JOURNAL OF THORACIC IMAGING, 1998, 13 (01) : 14 - 19
  • [50] Cerebral air embolism treated with hyperbaric oxygen therapy following percutaneous transthoracic computed tomography-guided needle biopsy of the lung
    Tomabechi, Makiko
    Kato, Kenichi
    Sone, Miyuki
    Ehara, Shigeru
    Sekimura, Kenshi
    Kizawa, Tetsuya
    Kin, Masakado
    [J]. RADIATION MEDICINE, 2008, 26 (06): : 379 - 383