Identification algorithm for polymer mixtures based on Py-GC/MS and its application for microplastic analysis in environmental samples

被引:57
|
作者
Matsui, Kazuko [1 ,2 ]
Ishimura, Takahisa [1 ]
Mattonai, Marco [1 ,2 ]
Iwai, Itsuko [3 ]
Watanabe, Atsushi [1 ]
Teramae, Norio [1 ,4 ]
Ohtani, Hajime [5 ]
Watanabe, Chuichi [1 ]
机构
[1] Frontier Labs Ltd, Koriyama, Fukushima 9638862, Japan
[2] Univ Pisa, Dept Chem & Ind Chem, Via Giuseppe Moruzzi 13, I-56124 Pisa, Italy
[3] Frontier Labs USA, Antioch, CA 94534 USA
[4] Tohoku Univ, Grad Sch Sci, Dept Chem, Sendai, Miyagi 9808578, Japan
[5] Nagoya Inst Technol, Grad Sch Engn, Dept Life Sci & Appl Chem, Nagoya, Aichi 4668555, Japan
关键词
SPECTROMETRY; IMPACTS;
D O I
10.1016/j.jaap.2020.104834
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Microplastics pollution is an acknowledged global issue, and new strategies are required to meet the increasing demand of standardized, fast and reliable measurements. Analytical pyrolysis coupled to gas chromatography and mass spectrometry (Py-GC/MS) is a promising technique to obtain qualitative and quantitative data on microplastics mixtures through the selection of a set of characteristic pyrolysis products for each polymer. However, this data processing method is time-consuming, and no automated algorithms are currently available. In the present work, a new method for the qualitative analysis of eleven types of synthetic polymers was developed, automated and implemented in the F-Search software, with the aim of proposing a standardized procedure for data processing in Py-GC/MS analysis of plastics mixtures. The method improves on the current literature, and is based on the generation of summated mass spectra (SMS) for each polymer, obtained by extracting specific m/z and retention index coordinates corresponding to characteristic pyrolysis products. The identification of a polymer is performed by comparing its SMS with those of a built-in library. After validation, the algorithm was tested on a reference sample containing all eleven investigated polymers. The algorithm provided relative standard deviations around 10%, and the results were used to estimate the lowest amount of polymer detectable in a sample, which was found lower than 1 μg for most polymers. The performance of the algorithm was also evaluated on a real sample from ocean water trawling, providing positive results for four different polymers. The performances of the algorithm are discussed, and possible future developments are outlined. © 2020 Elsevier B.V.
引用
收藏
页数:9
相关论文
共 50 条
  • [41] AYUMS: an algorithm for completely automatic quantitation based on LC-MS/MS proteome data and its application to the analysis of signal transduction
    Saito, Ayumu
    Nagasaki, Masao
    Oyama, Masaaki
    Kozuka-Hata, Hiroko
    Semba, Kentaro
    Sugano, Sumio
    Yamamoto, Tadashi
    Miyano, Satoru
    BMC BIOINFORMATICS, 2007, 8 (1)
  • [42] AYUMS: an algorithm for completely automatic quantitation based on LC-MS/MS proteome data and its application to the analysis of signal transduction
    Ayumu Saito
    Masao Nagasaki
    Masaaki Oyama
    Hiroko Kozuka-Hata
    Kentaro Semba
    Sumio Sugano
    Tadashi Yamamoto
    Satoru Miyano
    BMC Bioinformatics, 8
  • [43] Synthesis and characterization of molecularly imprinted polymer embedded composite cryogel discs: application for the selective extraction of cypermethrins from aqueous samples prior to GC-MS analysis
    Shaikh, Huma
    Andac, Muege
    Memon, Najma
    Bhanger, Muhammad Iqbal
    Nizamani, Shafi Muhammad
    Denizli, Adil
    RSC ADVANCES, 2015, 5 (34): : 26604 - 26615
  • [44] Occurrence of residual water within disk-based solid-phase extraction and its effect on GC-MS measurement of organic extracts of environmental samples
    Christine Erger
    Peter Balsaa
    Friedrich Werres
    Torsten C. Schmidt
    Analytical and Bioanalytical Chemistry, 2012, 403 : 2541 - 2552
  • [45] Occurrence of residual water within disk-based solid-phase extraction and its effect on GC-MS measurement of organic extracts of environmental samples
    Erger, Christine
    Balsaa, Peter
    Werres, Friedrich
    Schmidt, Torsten C.
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2012, 403 (09) : 2541 - 2552
  • [46] Develop of a multiway chemometric-based analytical method fulfilling regulatory identification criteria: Application to GC-MS pesticide residue analysis
    Real, B. D.
    Ortiz, M. C.
    Sarabia, L. A.
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2012, 910 : 122 - 137
  • [47] Solid-phase extraction based in tube filled-magnetic carbon nanotubes coupled with GC-MS for analysis of polycyclic aromatic hydrocarbons in environmental samples
    Zhou, Chanyuan
    Meng, Tiao
    Yang, Chunyan
    Yang, Yike
    Chinese Journal of Analysis Laboratory, 2021, 40 (09) : 1015 - 1020
  • [48] A novel chemiluminescent immunoassay for microcystin (MC) detection based on gold nanoparticles label and its application to MC analysis in aquatic environmental samples
    Hu, Chenlin
    Gan, Nanqin
    He, Zhike
    Song, Lirong
    INTERNATIONAL JOURNAL OF ENVIRONMENTAL ANALYTICAL CHEMISTRY, 2008, 88 (04) : 267 - 277
  • [49] Development of deep eutectic solvent-based ultrasonic assisted liquid-liquid microextraction coupled with GC-MS; application in analysis of organochlorine pesticides from cheese samples
    Maleki, Mohammad Rouhi
    Movassaghghazani, Mohammadhosein
    Mogaddam, Mohammad Reza Afshar
    MICROCHEMICAL JOURNAL, 2024, 206
  • [50] Development of a new continuous homogenous liquid phase microextraction procedure based on in-situ preparation of deep eutectic solvent; application in the analysis of aliphatic amines in urine samples by GC-MS
    Shagaghipour, Shabnam
    Mogaddam, Mohammad Reza Afshar
    Sorouraddin, Saeed Mohammad
    Farajzadeh, Mir Ali
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2024, 1237