Dosimetric impact of intrafraction changes in MR-guided high-dose-rate (HDR) brachytherapy for prostate cancer

被引:8
|
作者
Rink, Alexandra [1 ,2 ,3 ]
Borg, Jette [1 ,2 ]
Simeonov, Anna [1 ]
O'Leary, Gerald [4 ,5 ]
Helou, Joelle [1 ,2 ]
Menard, Cynthia [3 ,6 ]
Chung, Peter [1 ,2 ]
Jaffray, David A. [1 ,2 ,3 ,5 ,7 ]
Berlin, Alejandro [1 ,2 ]
机构
[1] Univ Hlth Network, Princess Margaret Canc Ctr, Radiat Med Program, Toronto, ON, Canada
[2] Univ Toronto, Dept Radiat Oncol, Toronto, ON, Canada
[3] TECHNA Inst, Toronto, ON, Canada
[4] Univ Toronto, Dept Anesthesia, Toronto, ON, Canada
[5] Univ Hlth Network, Toronto, ON, Canada
[6] Univ Montreal Hosp Res Ctr CRCHUM, Montreal, PQ, Canada
[7] Univ Toronto, Dept Med Biophys, Toronto, ON, Canada
关键词
MR-guided HDR; Prostate; Intrafraction dosimetry; Treatment verification; Edema; CATHETER MOVEMENT; MONOTHERAPY; FRACTION; VOLUME;
D O I
10.1016/j.brachy.2017.06.001
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
PURPOSE: To assess changes in implant and treatment volumes through the course of a prostate high-dose-rate brachytherapy procedure and their impact on plan quality metrics. METHODS AND MATERIALS: Sixteen MRI-guided high-dose-rate procedures included a post-treatment MR (ptMR) immediately after treatment delivery (135 min between MR scans). Target and organs at risk (OARs) were contoured, and catheters were reconstructed. The delivered treatment plan was applied to the ptMR image set. Volumes and dosimetrie parameters in the ptMR were evaluated and compared with the delivered plan using a paired two-tailed t-test with p < 0.05 considered statistically significant. RESULTS: An average increase of 8.9% in prostate volume was observed for whole-gland treatments, resulting in reduction in coverage for both prostate and planning target volume, reflected in decreased V-100 (mean 3.3% and 4.6%, respectively, p < 0.05), and D-90 (mean 7.1% and 7.6%, respectively, of prescription dose, p < 0.05). There was no significant change in doses to OARs. For partial-gland treatments, there was an increase in planning target volume (9.1%), resulting in reduced coverage and D90 (mean 3.6% and 12.4%, respectively, p < 0.05). A decrease in D-0.5cc, for bladder (3%, p < 0.05) was observed, with no significant changes in dose to other OARs. CONCLUSIONS: Volumetric changes were observed during the time between planning MR and ptMR. Nonetheless, treatment plans for both whole- and partial-gland therapies remained clinically acceptable. These results apply to clinical settings in which patients remain in the same position and under anesthesia during the entire treatment process. (C) 2017 American Brachytherapy Society. Published by Elsevier Inc. All rights reserved.
引用
收藏
页码:59 / 67
页数:9
相关论文
共 50 条
  • [1] Open MR-Guided High-Dose-Rate (HDR) Prostate Brachytherapy: Feasibility and Initial Experiences Open MR-Guided High-Dose-Rate (HDR) Prostate Brachytherapy
    Lakosi, Ferenc
    Antal, Gergely
    Vandulek, Csaba
    Kovacs, Arpad
    Toller, Gabor L.
    Rakasz, Istvan
    Bajzik, Gabor
    Hadjiev, Janaki
    Bogner, Peter
    Repa, Imre
    [J]. PATHOLOGY & ONCOLOGY RESEARCH, 2011, 17 (02) : 315 - 324
  • [2] Focal MR-Guided High-Dose-Rate Brachytherapy for Localized Prostate Cancer: A Prospective Clinical Trial
    Gutierrez, E.
    Ramotar, M.
    Helou, J.
    Raman, S.
    Glicksman, R.
    Rink, A.
    Chung, P.
    Weersink, R. A.
    Berlin, A.
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2022, 114 (03): : E221 - E221
  • [3] MR MODELLING OF THE RECTAL DOSIMETER PROBE DURING MR-GUIDED HIGH-DOSE-RATE (HDR) PROSTATE BRACHYTHERAPY: FEASIBILITY AND INITIAL EXPERIENCES
    Antal, G.
    Lakosi, F.
    Kovacs, A.
    Glavak, C.
    Hadjiev, J.
    Rakasz, I.
    Farkas, J.
    Vandulek, C.
    Repa, I.
    Bogner, P.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2009, 91 : S38 - S38
  • [4] Dosimetric feasibility of ablative dose escalated focal monotherapy with MRI-guided high-dose-rate (HDR) brachytherapy for prostate cancer
    Hosni, Ali
    Carlone, Marco
    Rink, Alexandra
    Menard, Cynthia
    Chung, Peter
    Berlin, Alejandro
    [J]. RADIOTHERAPY AND ONCOLOGY, 2017, 122 (01) : 103 - 108
  • [5] MR IMAGING-GUIDED HIGH-DOSE-RATE (HDR) PROSTATE BRACHYTHERAPY: FEASIBILITY AND INITIAL EXPERIENCES
    Lakosi, F.
    Antal, G.
    Vandulek, C.
    Kovacs, A.
    Hadjiev, J.
    Repa, I.
    Bogner, P.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2008, 88 : S188 - S188
  • [6] Dosimetric Evaluation of MR-Guided HDR Brachytherapy Planning for Cervical Cancer
    Kamio, Y.
    Barkati, M.
    Beliveau-Nadeau, D.
    [J]. MEDICAL PHYSICS, 2016, 43 (06) : 3854 - 3854
  • [7] Dosimetric Changes during Daily MR-Guided Pulse-Dose-Rate Brachytherapy for Cervix Cancer
    Morgia, M. L.
    Walsh, L.
    Xie, J.
    Jezioranski, J.
    Cho, Y.
    Oh, S.
    Keeler, K.
    Fyles, A.
    Milosevic, M.
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2011, 81 (02): : S453 - S453
  • [8] Comparison of CT-guided and MR-guided HDR brachytherapy for prostate cancer
    Haverkamp, U
    Prümer, BA
    Krause, K
    Tschuschke, C
    Blumberg, J
    Benkel, P
    Fischedick, AR
    [J]. STRAHLENTHERAPIE UND ONKOLOGIE, 2004, 180 : 118 - 119
  • [9] Dosimetric Comparison of High Dose Rate Brachytherapy vs MR-Guided SBRT Boost for Cervical Cancer
    Dincer, N.
    Ugurluer, G.
    Mustafayev, T. Zoto
    Serkizyan, A.
    Aydin, G.
    Gungor, G.
    Atalar, B.
    Ozyar, E.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2023, 182 : S1808 - S1808
  • [10] The emerging role of high-dose-rate (HDR) brachytherapy as monotherapy for prostate cancer
    Yoshioka, Yasuo
    Yoshida, Ken
    Yamazaki, Hideya
    Nonomura, Norio
    Ogawa, Kazuhiko
    [J]. JOURNAL OF RADIATION RESEARCH, 2013, 54 (05) : 781 - 788