Custom-Made Angled inserts for Tibial Coronal Malalignment in Total Knee Arthroplasty

被引:2
|
作者
Sah, Alexander P. [1 ]
Scott, Richard D. [2 ]
Springer, Bryan D. [3 ]
Bono, James V. [2 ]
Deshmukh, Rahul V. [4 ]
Thornhill, Thomas S. [1 ]
机构
[1] Brigham & Womens Hosp, Dept Orthoped Surg, Boston, MA 02115 USA
[2] Nevv England Baptist Hosp, Dept Orthoped Surg, Boston, MA USA
[3] Charlotte Hip & Knee Ctr, Charlotte, NC USA
[4] St Vincents Hlth Syst, Jacksonville, FL USA
来源
JOURNAL OF ARTHROPLASTY | 2009年 / 24卷 / 02期
关键词
insert exchange; angled; malalignment; knee arthroplasty; custom; coronal; ALIGNMENT; PROSTHESIS; PATIENT; SURVIVORSHIP; EXCHANGE; FAILURE;
D O I
10.1016/j.arth.2007.08.014
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Component malalignment continues to be common after knee arthroplasty, with treatment often requiring prosthesis revision. From 1993 to 2005, 9 angled inserts were placed to correct coronal plane deformities due to tibial component malposition. Insert exchange occurred at an average of 67 months (range, 5-149 months) from the index procedure. Two patients died before 2-year follow-up, for an overall average of 60 months (range, 12-157 months) follow-up. Limb alignment improved and Knee Society knee and function scores increased from 68 and 71, respectively, to 92 and 91, postoperatively. All patients reported excellent satisfaction with no revisions at average 5-year follow-up. It is important to be aware that specifically designed angled inserts are available and may provide a conservative method to correct mild to moderate tibial malalignment in rare cases.
引用
收藏
页码:288 / 296
页数:9
相关论文
共 50 条
  • [1] Angled polyethylene insert exchange for sagittal tibial malalignment in total knee arthroplasty
    Sah, Alexander P.
    Scott, Richard D.
    Iorio, Richard
    JOURNAL OF ARTHROPLASTY, 2008, 23 (01): : 141 - 144
  • [2] Custom-made asymmetric polyethylene liner to correct tibial component malposition in total knee arthroplasty - a case report
    Kappel, Andreas
    Blom, Claes Sjorslev
    El-Galaly, Anders
    ACTA ORTHOPAEDICA, 2019, 90 (02) : 187 - 189
  • [3] Thickness of tibial inserts in total knee arthroplasty
    Weber, AB
    Morris, HG
    JOURNAL OF ARTHROPLASTY, 1996, 11 (07): : 856 - 858
  • [4] Rotational malalignment of the femoral and tibial components in total knee arthroplasty
    Nagamine, R
    Whiteside, LA
    Miura, H
    Urabe, K
    Matsuda, S
    Iwamoto, Y
    JOINT ARTHROPLASTY, 1999, : 373 - 383
  • [5] Custom-made cementless revision total knee arthroplasty in a patient with metal and bone cement hypersensitivity
    Logoluso, N.
    Ciliberto, R.
    Morelli, I
    Peretti, G. M.
    Pellegrini, A., V
    JOURNAL OF BIOLOGICAL REGULATORS AND HOMEOSTATIC AGENTS, 2021, 35 (02): : 791 - 795
  • [6] The Critical Dimension Definition of Femoral for Custom-made Total Knee Arthroplasty by the Application of Geometric Modeling
    Chen, Hung-Shyong
    Bin, Tsai Yau
    Huang, Chyouhwu
    Lee, Jeng-Nan
    Kung, Huang-Kuang
    LIFE SCIENCE JOURNAL-ACTA ZHENGZHOU UNIVERSITY OVERSEAS EDITION, 2012, 9 (02): : 196 - 201
  • [7] Custom-Made Cutting Blocks for Total Knee Arthroplasty: Two Case Reports and Preliminary Results
    Tirnovanu, S. D.
    Savin, L.
    Forna, N.
    Scolobiuc, D.
    Antonescu, I. C.
    Sirbu, M. T.
    Sirbu, P. D.
    2021 INTERNATIONAL CONFERENCE ON E-HEALTH AND BIOENGINEERING (EHB 2021), 9TH EDITION, 2021,
  • [8] Custom-fit total knee arthroplasty (OtisKnee) results in malalignment
    Klatt, Brian A.
    Goyal, Nitin
    Austin, Matthew S.
    Hozack, William J.
    JOURNAL OF ARTHROPLASTY, 2008, 23 (01): : 26 - 29
  • [9] Conversion of Total Wrist Arthroplasty to Arthrodesis with a Custom-Made Peg
    Reigstad, Ole
    Rokkum, Magne
    JOURNAL OF WRIST SURGERY, 2014, 3 (03) : 211 - 215
  • [10] Custom-made acetabular implants in revision total hip arthroplasty
    von Lewinski, Gabriela
    ORTHOPADE, 2020, 49 (05): : 417 - 423