Fault detection of antenna arrays using infrared thermography

被引:7
|
作者
Muzaffar, Khalid [1 ]
Giri, Lalat Indu [1 ]
Chatterjee, Krishnendu [1 ]
Tuli, Suneet [1 ]
Koul, Shiban [1 ]
机构
[1] Indian Inst Technol Delhi, Ctr Appl Res Elect, New Delhi 110016, India
关键词
Infrared thermography; IR Camera; Electric field; Absorption screen; Faulty elements;
D O I
10.1016/j.infrared.2015.06.010
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
A fast and easy method for fault detection in antenna arrays using infrared thermography is presented. A thin, minimally perturbing, microwave absorption screen made of carbon loaded polymer is kept close in front of the faulty array. Electromagnetic waves falling on the screen increase its temperature. This temperature profile on the screen is identical to electric field intensity profile at the screen location. There is no temperature rise observed on the screen corresponding to non-radiating (faulty) elements and hence can be easily detected by IR thermography. The array input power is modulated at a low frequency which permits thermography to detect even weak fields. It also improves the resolution of thermal images. The power fed to the array is only 30 dBm. In order to show the utility of this technique, an example of 14 GHz 4 x 4 patch antenna array is given. The simulations are carried in CST Microwave Studio 2013. A good agreement between simulation and experimental results is observed. (C) 2015 Elsevier B.V. All rights reserved.
引用
收藏
页码:464 / 468
页数:5
相关论文
共 50 条
  • [21] Power Handling Test of a L-band Antenna Using Infrared Thermography
    Laffont, A.
    Faure, S.
    Mazingue, G.
    [J]. 2024 18TH EUROPEAN CONFERENCE ON ANTENNAS AND PROPAGATION, EUCAP, 2024,
  • [22] Subsurface defect detection in FRP composites using infrared thermography
    Halabe, UB
    Vasudevan, A
    GangaRao, HVS
    Klinkhachom, P
    Lonkar, G
    [J]. Review of Progress in Quantitative Nondestructive Evaluation, Vols 24A and 24B, 2005, 760 : 1477 - 1484
  • [23] Detection of Delaminations in Reinforced Concrete Bridges Using Infrared Thermography
    Rocha, J. H. A.
    Povoas, Y.
    [J]. REVISTA INGENIERIA DE CONSTRUCCION, 2019, 34 (01): : 55 - 64
  • [24] Detection of pathogenic gram negative bacteria using infrared thermography
    Lahiri, B. B.
    Divya, M. P.
    Bagavathiappan, S.
    Thomas, Sabu
    Philip, John
    [J]. INFRARED PHYSICS & TECHNOLOGY, 2012, 55 (06) : 485 - 490
  • [25] Automatic seepage detection in cable tunnels using infrared thermography
    Lu, Zilin
    Zhu, Fulong
    Shi, Lang
    Wang, Fengren
    Zeng, Pengjun
    Hu, Jianxiong
    Liu, Xiaojian
    Xu, Yixin
    Chen, Qian
    [J]. MEASUREMENT SCIENCE AND TECHNOLOGY, 2019, 30 (11)
  • [26] A novel intelligent fault diagnosis method for electrical equipment using infrared thermography
    Zou, Hui
    Huang, Fuzhen
    [J]. INFRARED PHYSICS & TECHNOLOGY, 2015, 73 : 29 - 35
  • [27] Fault Detection in Electrical Equipment by Infrared Thermography Images Using Spiking Neural Network Through Hybrid Feature Selection
    Chellamuthu, Shanmugam
    Sekaran, E. Chandira
    Annamalai, Sivakumar
    Palanisamy, A. R.
    [J]. JOURNAL OF CIRCUITS SYSTEMS AND COMPUTERS, 2023, 32 (08)
  • [28] Time-Reversal Detection Using Antenna Arrays
    Jin, Yuanwei
    Moura, Jose M. F.
    [J]. IEEE TRANSACTIONS ON SIGNAL PROCESSING, 2009, 57 (04) : 1396 - 1414
  • [29] Using EMPHASIS for the Thermography-Based Fault Detection in Photovoltaic Plants
    Catalano, Antonio Pio
    Scognamillo, Ciro
    Guerriero, Pierluigi
    Daliento, Santolo
    D'Alessandro, Vincenzo
    [J]. ENERGIES, 2021, 14 (06)
  • [30] Monitoring linear antenna arrays using an exponentially weighted moving average-based fault detection scheme
    Harrou, Fouzi
    Nounou, Mohamed N.
    [J]. SYSTEMS SCIENCE & CONTROL ENGINEERING, 2014, 2 (01): : 433 - 443