Fault detection of antenna arrays using infrared thermography

被引:7
|
作者
Muzaffar, Khalid [1 ]
Giri, Lalat Indu [1 ]
Chatterjee, Krishnendu [1 ]
Tuli, Suneet [1 ]
Koul, Shiban [1 ]
机构
[1] Indian Inst Technol Delhi, Ctr Appl Res Elect, New Delhi 110016, India
关键词
Infrared thermography; IR Camera; Electric field; Absorption screen; Faulty elements;
D O I
10.1016/j.infrared.2015.06.010
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
A fast and easy method for fault detection in antenna arrays using infrared thermography is presented. A thin, minimally perturbing, microwave absorption screen made of carbon loaded polymer is kept close in front of the faulty array. Electromagnetic waves falling on the screen increase its temperature. This temperature profile on the screen is identical to electric field intensity profile at the screen location. There is no temperature rise observed on the screen corresponding to non-radiating (faulty) elements and hence can be easily detected by IR thermography. The array input power is modulated at a low frequency which permits thermography to detect even weak fields. It also improves the resolution of thermal images. The power fed to the array is only 30 dBm. In order to show the utility of this technique, an example of 14 GHz 4 x 4 patch antenna array is given. The simulations are carried in CST Microwave Studio 2013. A good agreement between simulation and experimental results is observed. (C) 2015 Elsevier B.V. All rights reserved.
引用
收藏
页码:464 / 468
页数:5
相关论文
共 50 条
  • [1] Fault detection in diesel engines using infrared thermography
    Martínez, VM
    Martínez, BT
    González, PO
    Uría, RWP
    [J]. INSIGHT, 2002, 44 (04) : 228 - 232
  • [2] USING NEURAL NETWORKS FOR FAULT DETECTION IN PLANAR ANTENNA ARRAYS
    Vakula, D.
    Sarma, N. V. S. N.
    [J]. PROGRESS IN ELECTROMAGNETICS RESEARCH LETTERS, 2010, 14 : 21 - 30
  • [3] Fault Detection Method for Power MOSFET Based on Infrared Thermography
    Chen, Danjiang
    Liu, Yutian
    [J]. 2018 37TH CHINESE CONTROL CONFERENCE (CCC), 2018, : 6073 - 6076
  • [4] Detection of Dentinal Microcracks Using Infrared Thermography
    Matsushita-Tokugawa, Manami
    Miura, Jiro
    Iwami, Yukiteru
    Sakagami, Takahide
    Izumi, Yui
    Mori, Naoya
    Hayashi, Mikako
    Imazato, Satoshi
    Takeshige, Fumio
    Ebisu, Shigeyuki
    [J]. JOURNAL OF ENDODONTICS, 2013, 39 (01) : 88 - 91
  • [5] A Study on Real-Time Fault Monitoring Detection Method of Bearing Using the Infrared Thermography
    Kim, Ho-Jong
    Hong, Dong-Pyo
    Kim, Won-Tae
    [J]. JOURNAL OF THE KOREAN SOCIETY FOR NONDESTRUCTIVE TESTING, 2013, 33 (04) : 330 - 335
  • [6] Detection of wood damages using infrared thermography
    Pitarma, Rui
    Crisostomo, Joao
    Pereira, Livia
    [J]. 16TH INTERNATIONAL CONFERENCE ON MOBILE SYSTEMS AND PERVASIVE COMPUTING (MOBISPC 2019),THE 14TH INTERNATIONAL CONFERENCE ON FUTURE NETWORKS AND COMMUNICATIONS (FNC-2019),THE 9TH INTERNATIONAL CONFERENCE ON SUSTAINABLE ENERGY INFORMATION TECHNOLOGY, 2019, 155 : 480 - 486
  • [7] Infrared thermography image processing for the electromechanical fault detection on the kinematic chain
    Ivan Alvarado-Hernandez, Alvaro
    Zamudio-Ramirez, Israel
    Alfonso Antonino-Daviu, Jose
    Alfredo Osornio-Rios, Roque
    [J]. IECON 2021 - 47TH ANNUAL CONFERENCE OF THE IEEE INDUSTRIAL ELECTRONICS SOCIETY, 2021,
  • [8] Hotspots Detection in Photovoltaic Modules Using Infrared Thermography
    Salazar, April M.
    Macabebe, Erees Queen B.
    [J]. 2016 3RD INTERNATIONAL CONFERENCE ON MANUFACTURING AND INDUSTRIAL TECHNOLOGIES, 2016, 70
  • [9] Automatic detection of subsurface defects using infrared thermography
    Lonkar, GM
    Klinkhachom, P
    Halabe, UB
    GangaRao, HVS
    [J]. REVIEW OF PROGRESS IN QUANTITATIVE NONDESTRUCTIVE EVALUATION, VOLS 24A AND 24B, 2005, 760 : 1469 - 1476
  • [10] Detection of Escherichia coli growth using infrared thermography
    Hernandez-Eugenio, Guadalupe
    Echeverria-Landin, Eliubi
    Schlam, Federico Hahn
    [J]. AGROCIENCIA, 2007, 41 (05) : 503 - 511