In an evaluation of techniques for dispensing Tc-99(m)-tetrofosmin injections, variability in radiochemical purity measured by the recommended 'cut-and-count' thin-layer chromatographic (TLC) analytical technique was observed. This was due to inconsistency in the position of the Tc-99(m)-tetrofosmin on the chromatography plate. An investigation was therefore undertaken to identify the factors which influence the Rf value of Tc-99(m)-tetrofosmin and the subsequent effect on the values obtained in the measurement of radiochemical purity. TLC was performed on an ITLC/SG stationary phase with a mobile phase of dichloromethane:acetone (65:35). On a satisfactory chromatogram, the main peak had an Rf of approximately 0.5 and the radiochemical purity was measured at >90%. The Rf of the main peak and the measured radiochemical purity were found to increase as the size of the sample applied to the plate was increased. Force-drying the sample spot after application to the TLC plate gave a single peak with an Rf of 0. The dimensions of the tank and the time allowed for mobile phase saturation did not affect the outcome of the analysis. Small variations in the composition of the mobile phase affected the Rf of the main peak but not the measured radiochemical purity. TLC plates that were dried at 11 degrees C before use were found to give distorted chromatograms and unreliable measurements of radiochemical purity. In conclusion, when using TLC to measure the radiochemical purity of Tc-99(m)-tetrofosmin, the following precautions should be observed: (1) the sample spot applied to the TLC plate should be in the range 10-20 mu l; (2) the spot should not be force-dried with air; and (3) ITLC/SG plates should not be dried before use. ((C) 1999 Lippincott Williams & Wilkins).
引用
收藏
页码:439 / 444
页数:6
相关论文
共 50 条
  • [31] Thin-Layer Chromatographic Analysis of Steroids: A Review
    Bhawani, S. A.
    Sulaiman, O.
    Hashim, R.
    Ibrahim, M. N. Mohamad
    TROPICAL JOURNAL OF PHARMACEUTICAL RESEARCH, 2010, 9 (03) : 301 - 313
  • [32] THIN-LAYER CHROMATOGRAPHIC QUANTITATIVE-ANALYSIS
    KIRCHNER, JG
    JOURNAL OF CHROMATOGRAPHY, 1973, 82 (01): : 101 - 115
  • [33] Thin-Layer and High-Performance Thin-Layer Chromatographic Analysis of Biological Samples
    Sherma, Joseph
    Fried, Bernard
    ADVANCES IN CHROMATOGRAPHY, VOL 49, 2011, 49 : 401 - 421
  • [34] 定量门控99Tcm-tetrofosmin心肌显像测量运动负荷后左室功能
    徐浩
    吴秋莲
    弓健
    广东医学, 2005, (10) : 94 - 96
  • [35] 99Tcm-tetrofosmin在乳腺癌及其转移灶显像中的应用
    章斌
    国外医学(放射医学核医学分册), 2001, (01) : 12 - 15
  • [36] 99Tcm-tetrofosmin肺癌显像的临床研究(与18F-FDGPET对比)
    王辉
    中华核医学杂志, 1999, (01) : 10 - 12
  • [37] 比较恶性与非恶性乳腺细胞系对99Tcm-MIBI和99Tcm-tetrofosmin的吸收
    Rodrigues M
    杨敏
    裴著果
    国外医学(放射医学核医学分册), 2001, (01) : 19 - 19
  • [38] THIN-LAYER CHROMATOGRAPHIC AIDS
    BECKSTEAD, HD
    FRENCH, WN
    SMITH, SJ
    JOURNAL OF CHROMATOGRAPHY, 1967, 31 (01): : 226 - +
  • [39] THIN-LAYER CHROMATOGRAPHIC EVIDENCE OF PROLINE PEPTIDIZATION IN SOLUTION AND ITS THIN-LAYER CHROMATOGRAPHIC ENANTIOSEPARATION
    Sajewicz, Mieczyslaw
    Matlengiewicz, Marek
    Juziuk, Malgorzata
    Penkala, Maria
    Weloe, Marcel
    Schulz, Michael
    Kowalska, Teresa
    JOURNAL OF LIQUID CHROMATOGRAPHY & RELATED TECHNOLOGIES, 2013, 36 (17) : 2497 - 2511
  • [40] Assessment of 99Tcm-tetrofosmin lung uptake:: A modified method to avoid, the contribution from high chest wall activity
    Heiba, SI
    Ziada, G
    Higazy, E
    Saleh, M
    Elgazzar, AH
    NUCLEAR MEDICINE COMMUNICATIONS, 1998, 19 (09) : 859 - 866