Thermal performance analysis of a ground-coupled heat pump integrated with building foundation in summer

被引:26
|
作者
Lee, Jin-Uk [1 ]
Kim, Taeyeon [2 ]
Leigh, Seung-Bok [2 ]
机构
[1] POSCO Global R&D Ctr, Res Inst Sci & Technol POSCO, Inchon 406840, South Korea
[2] Yonsei Univ, Dept Architectural Engn, Seoul 120749, South Korea
关键词
Renewable energy; Geothermal; Building energy; GCHP; PHC pile; SOURCE AIR-CONDITIONERS; SOUTH-AFRICA; SYSTEM; EXCHANGERS; EXPERIENCE; OPERATION;
D O I
10.1016/j.enbuild.2012.12.016
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Geothermal energy has been provided to improve the energy performance of buildings with great support from the government in Korea. However, despite the many advantages of using a ground-coupled heat pump (GCHP) with geothermal energy, the high construction cost of the ground-coupled heat exchanger (GCHE) is the primary obstacle to prevent the supply and spread of GCHPs. In this study, in order to overcome the problems of the conventional GCHP, a GCHP integrated with a PHC (prestressed high-strength concrete) pile, which is used in the foundation of buildings, was introduced and its thermal performance was analyzed through experiments conducted in summer. To increase the thermal performance, a coil-type pipe was used. The PHC-pile-integrated GCHP was installed at a depth of 15 m. However, because it was installed in the beneath of the building, it was not largely affected by the outdoor temperature. The measured effective thermal conductivity was 3.69 W/m degrees C, which is similar to that of a conventional vertical GCHP. Also, the COP was determined to be 3.9-4.3, which is slightly lower than the conventional vertical GCHP. However, considering the fact that the expensive drilling cost could be mitigated by 83.7%, the thermal performances were satisfactory. (C) 2012 Elsevier B.V. All rights reserved.
引用
收藏
页码:37 / 43
页数:7
相关论文
共 50 条
  • [21] An hourly simulation method for the energy performance of an office building served by a ground-coupled heat pump system
    Zhang, Linfeng
    Huang, Gongsheng
    Zhang, Quan
    Wang, Jinggang
    RENEWABLE ENERGY, 2018, 126 : 495 - 508
  • [22] A new integrated system with cooling storage in soil and ground-coupled heat pump
    Yu, Yanshun
    Ma, Zuiliang
    Li, Xianting
    APPLIED THERMAL ENGINEERING, 2008, 28 (11-12) : 1450 - 1462
  • [23] Ground-coupled heat transfer in building simulation
    Bansal, P
    Jones, R
    Addison, M
    PROCEEDINGS OF THE 23RD NATIONAL PASSIVE SOLAR CONFERENCE, 1998, 23 : 249 - 255
  • [24] Thermal-economic modeling and optimization of vertical ground-coupled heat pump
    Sanaye, Sepehr
    Niroomand, Behzad
    ENERGY CONVERSION AND MANAGEMENT, 2009, 50 (04) : 1136 - 1147
  • [25] Experimental study of a ground-coupled heat pump combined with thermal solar collectors
    Trillat-Berdal, V.
    Souyri, B.
    Fraisse, G.
    ENERGY AND BUILDINGS, 2006, 38 (12) : 1477 - 1484
  • [26] Energy saving analysis of a hybrid ground-coupled heat pump project
    Chen, Jiufa
    Xue, Qin
    Qiao, Weilai
    An, Erming
    Journal of Southeast University (English Edition), 2010, 26 (02) : 177 - 181
  • [27] Numerical and experimental analysis of a horizontal ground-coupled heat pump system
    Esen, Hikmet
    Inalli, Mustafa
    Esen, Mehmet
    BUILDING AND ENVIRONMENT, 2007, 42 (03) : 1126 - 1134
  • [28] Study on hybrid ground-coupled heat pump systems
    Man Yi
    Yang Hongxing
    Fang Zhaohong
    ENERGY AND BUILDINGS, 2008, 40 (11) : 2028 - 2036
  • [29] Effects of the total borehole length and of the heat pump inverter on the performance of a ground-coupled heat pump system
    Naldi, Claudia
    Zanchini, Enzo
    APPLIED THERMAL ENGINEERING, 2018, 128 : 306 - 319
  • [30] Numerical simulation of a horizontal ground-coupled heat pump
    Javaherdeh, K.
    Karimi, H.
    International Journal of Energy and Environmental Engineering, 2010, 1 (01) : 27 - 35