The sensitivity of motor response to needle nerve stimulation during ultrasound guided interscalene catheter placement

被引:24
|
作者
Fredrickson, Michael J. [1 ,2 ]
机构
[1] Univ Auckland, Fac Med & Hlth Sci, Dept Anaesthesiol, Auckland, New Zealand
[2] Auckland City Hosp, Auckland, New Zealand
关键词
ultrasound; interscalene; catheter; continuous; perineural;
D O I
10.1016/j.rapm.2007.12.014
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Background and Objectives: Neurostimulation during single shot interscalene block has a significant false negative motor response rate. Compared with tangential needle approaches for single shot block, interscalene catheter (ISC) placement commonly involves Tuohy needles inserted longitudinally to the brachial Plexus. This study aimed to determine the sensitivity of neurostimulation during ultrasound-guided ISC needle placement, and the feasibility of all ultrasound-guided ISC needle endpoint. Methods: one hundred filty-five consecutive nonstimulating ISCs were placed with the needle tip position confirmed by the sonographic spread of 5 mL, dextrose 5%. Catheter advancement was then blind 2 to 3 cm past the needle tip. A 0.8 mA electrical stimulus at 2 Hz was applied throughout. When a satisfactory image was obtained, neurostimulation was ignored and the minimum motor response amplitude noted. If imaging was equivocal, a brief appropriate motor response at 0.8 mA was sought. A sustained response at < 0.5 mA was only Sought if imaging was suboptimal. Prior to Surgery Conducted under general anesthesia, 30 mL ropivacanie 0.5%, was administered through the ISC. Catheter Success was defined as a recovery room numerical rating pain score of <= 2 (scale, 0-10). Results: In 57% of patients, a Muscle response was not elicited. All ultrasound needle endpoint was used in 92% of ISC placements, of which 96% were successful. Sustained twitches at < 0.5 mA were obtained in 12 (8%) patients, 6 (4%) of these deliberately sought because of suboptimal imaging. Catheter success overall was 95%. Conclusions: This Study suggests that the false negative motor response rate for longitudinal ISC needle placement is higher than the false negative response rate associated with tangential needle approach interscalene block. An ultrasound guided ISC needle endpoint is a feasible alternative to a neurostimulation endpoint.
引用
收藏
页码:291 / 296
页数:6
相关论文
共 50 条
  • [41] Ultrasound-guided popliteal block demonstrates an atypical motor response to nerve stimulation in 2 patients with diabetes mellitus
    Sites, BD
    Gallagher, J
    Sparks, M
    REGIONAL ANESTHESIA AND PAIN MEDICINE, 2003, 28 (05) : 479 - 482
  • [42] Ultrasound compared with nerve stimulation guidance for peripheral nerve catheter placement: a meta-analysis of randomized controlled trials
    Schnabel, A.
    Meyer-Friessem, C. H.
    Zahn, P. K.
    Pogatzki-Zahn, E. M.
    BRITISH JOURNAL OF ANAESTHESIA, 2013, 111 (04) : 564 - 572
  • [43] A Standardized Method for 4D Ultrasound-Guided Peripheral Nerve Blockade and Catheter Placement
    Clendenen, N. J.
    Robards, C. B.
    Clendenen, S. R.
    BIOMED RESEARCH INTERNATIONAL, 2014, 2014
  • [44] Dynamic Needle Tip Positioning for Ultrasound-Guided Placement of a Peripherally Inserted Central Catheter in Pediatric Patients
    Takeshita, Jun
    Inata, Yu
    Ito, Yukie
    Nishiyama, Kei
    Shimizu, Yoshiyuki
    Takeuchi, Muneyuki
    Shime, Nobuaki
    JOURNAL OF CARDIOTHORACIC AND VASCULAR ANESTHESIA, 2020, 34 (01) : 114 - 118
  • [45] Central venous catheter placement according to ultrasound guided with atrial electrode and ultrasound guided alone
    Sanchez Robayo, Kelly Johana
    Alfonso Rodriguez, Ciro
    Julio Melendez, Hector
    ANESTHESIA AND ANALGESIA, 2021, 133 (3S_SUPPL): : 234 - 234
  • [46] Perforation of the median nerve with an acupuncture needle guided by ultrasound
    Kessler, Jens
    Streitberger, Konrad
    ACUPUNCTURE IN MEDICINE, 2008, 26 (04) : 231 - 233
  • [48] Improved safety and efficacy of ultrasound-guided interscalene nerve block vs a nerve-stimulator guided technique
    Girdler-Hardy, T. P.
    Webb, C.
    Menon, G.
    BRITISH JOURNAL OF ANAESTHESIA, 2015, 115 (03) : 474 - 475
  • [49] Cardiac Arrest During an Ultrasound-Guided Sciatic Nerve Block Combined With Nerve Stimulation
    Gnaho, Alexandre
    Eyrieux, Sandrine
    Gentili, Marc
    REGIONAL ANESTHESIA AND PAIN MEDICINE, 2009, 34 (03) : 278 - 278
  • [50] An augmented reality simulator for ultrasound guided needle placement training
    D. Magee
    Y. Zhu
    R. Ratnalingam
    P. Gardner
    D. Kessel
    Medical & Biological Engineering & Computing, 2007, 45 : 957 - 967