The sensitivity of motor response to needle nerve stimulation during ultrasound guided interscalene catheter placement

被引:24
|
作者
Fredrickson, Michael J. [1 ,2 ]
机构
[1] Univ Auckland, Fac Med & Hlth Sci, Dept Anaesthesiol, Auckland, New Zealand
[2] Auckland City Hosp, Auckland, New Zealand
关键词
ultrasound; interscalene; catheter; continuous; perineural;
D O I
10.1016/j.rapm.2007.12.014
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Background and Objectives: Neurostimulation during single shot interscalene block has a significant false negative motor response rate. Compared with tangential needle approaches for single shot block, interscalene catheter (ISC) placement commonly involves Tuohy needles inserted longitudinally to the brachial Plexus. This study aimed to determine the sensitivity of neurostimulation during ultrasound-guided ISC needle placement, and the feasibility of all ultrasound-guided ISC needle endpoint. Methods: one hundred filty-five consecutive nonstimulating ISCs were placed with the needle tip position confirmed by the sonographic spread of 5 mL, dextrose 5%. Catheter advancement was then blind 2 to 3 cm past the needle tip. A 0.8 mA electrical stimulus at 2 Hz was applied throughout. When a satisfactory image was obtained, neurostimulation was ignored and the minimum motor response amplitude noted. If imaging was equivocal, a brief appropriate motor response at 0.8 mA was sought. A sustained response at < 0.5 mA was only Sought if imaging was suboptimal. Prior to Surgery Conducted under general anesthesia, 30 mL ropivacanie 0.5%, was administered through the ISC. Catheter Success was defined as a recovery room numerical rating pain score of <= 2 (scale, 0-10). Results: In 57% of patients, a Muscle response was not elicited. All ultrasound needle endpoint was used in 92% of ISC placements, of which 96% were successful. Sustained twitches at < 0.5 mA were obtained in 12 (8%) patients, 6 (4%) of these deliberately sought because of suboptimal imaging. Catheter success overall was 95%. Conclusions: This Study suggests that the false negative motor response rate for longitudinal ISC needle placement is higher than the false negative response rate associated with tangential needle approach interscalene block. An ultrasound guided ISC needle endpoint is a feasible alternative to a neurostimulation endpoint.
引用
收藏
页码:291 / 296
页数:6
相关论文
共 50 条
  • [1] Brachial Plexus Entrapment of Interscalene Nerve Catheter after Uncomplicated Ultrasound-Guided Placement
    Bowens, Clifford, Jr.
    Briggs, Eric R.
    Malchow, Randall J.
    PAIN MEDICINE, 2011, 12 (07) : 1117 - 1120
  • [2] Ultrasound-guided interscalene needle placement produces successful anesthesia regardless of motor stimulation above or below 0.5 mA
    Sinha, Sanjay K.
    Abrams, Jonathan H.
    Weller, Robert S.
    ANESTHESIA AND ANALGESIA, 2007, 105 (03): : 848 - 852
  • [3] Posterior tibial nerve stimulation: is ultrasound guided needle placement more accurate?
    Lomax, Steven J.
    Haehn, Daniela A.
    Robinson, Eric
    Page, Rachel Pung
    Bittencourt, Edsel
    Hurdle, Mark F. B.
    Petrou, Steven P.
    CANADIAN JOURNAL OF UROLOGY, 2021, 28 (04) : 10778 - 10782
  • [4] Ultrasound-Guided Posterior Approach for the Placement of a Continuous Interscalene Catheter
    Antonakakis, John G.
    Site, Brian D.
    Shiffrin, Jeffrey
    REGIONAL ANESTHESIA AND PAIN MEDICINE, 2009, 34 (01) : 64 - 68
  • [5] Subepineurial Injection in Ultrasound-Guided Interscalene Needle Tip Placement
    Orebaugh, Steven L.
    McFadden, Kathryn
    Skorupan, Havyn
    Bigeleisen, Paul E.
    REGIONAL ANESTHESIA AND PAIN MEDICINE, 2010, 35 (05) : 450 - 454
  • [6] Interscalene Perineural Catheter Placement Using an Ultrasound-Guided Posterior Approach
    Mariano, Edward R.
    Loland, Vanessa J.
    Ilfeld, Brian M.
    REGIONAL ANESTHESIA AND PAIN MEDICINE, 2009, 34 (01) : 60 - 63
  • [7] Feasibility of ultrasound-guided posterior approach for interscalene catheter placement during arthroscopic shoulder surgery
    Shin, Hyeon Ju
    Ahn, Jae Hyun
    Jung, Hye In
    Lim, Choon Hak
    Shin, Hye Won
    Lee, Hye Won
    Lim, Hae Ja
    Yoon, Suk Min
    Chang, Seong Ho
    KOREAN JOURNAL OF ANESTHESIOLOGY, 2011, 61 (06) : 475 - 481
  • [8] The long-axis view identifies atypical anatomy during ultrasound guided interscalene catheter placement
    Soeding, P. F.
    Eizenberg, N.
    ANAESTHESIA AND INTENSIVE CARE, 2010, 38 (05) : 962 - 964
  • [9] The sensitivity of motor response to nerve stimulation and paresthesia for nerve localization as evaluated by ultrasound
    Perlas, Anahi
    Niazi, Ahtsham
    McCartney, Colin
    Chan, Vincent
    Xu, Daquan
    Abbas, Sherif
    REGIONAL ANESTHESIA AND PAIN MEDICINE, 2006, 31 (05) : 445 - 450
  • [10] A Prospective Randomized Comparison of Ultrasound and Neurostimulation as Needle End Points for Interscalene Catheter Placement
    Fredrickson, Michael J.
    Ball, Craig M.
    Dalgleish, Adam J.
    Stewart, Alistair W.
    Short, Tim G.
    ANESTHESIA AND ANALGESIA, 2009, 108 (05): : 1695 - 1700