Effect of CT Realignment on Attenuation Corrected SPECT/CT Myocardial Perfusion Studies

被引:0
|
作者
Siennicki, J. [1 ]
Kovacevic-Kusmierek, K. [1 ]
Kusmierek, J. [2 ]
Chizynski, K. [3 ]
Kasprzak, J. D. [4 ]
Gawor, R. [5 ]
Plachcinska, A. [1 ]
机构
[1] Med Univ Lodz, Dept Qual Control & Radiol Protect, Lodz, Poland
[2] Med Univ Lodz, Dept Nucl Med, Lodz, Poland
[3] Med Univ Lodz, Dept Invas Cardiol, Lodz, Poland
[4] Med Univ Lodz, Chair & Dept Cardiol, Lodz, Poland
[5] Nicolas Copernicus Specialist Dist Hosp, Dept Cardiol, Lodz, Poland
关键词
D O I
暂无
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
P0373
引用
收藏
页码:S426 / S426
页数:1
相关论文
共 50 条
  • [1] Effect of CT misalignment on attenuation - corrected myocardial perfusion SPECT
    Plachcinska, Anna
    Wlodarczyk, Michal
    Drozdz, Jaroslaw
    Chizynski, Krzysztof
    Peruga, Jan Z.
    Kasprzak, Jaroslaw D.
    Kusmierek, Jacek
    NUCLEAR MEDICINE REVIEW, 2015, 18 (02) : 78 - 83
  • [2] SPECT and CT misalignment in myocardial perfusion scintigraphy with attenuation correction: effect of CT realignment on study result
    Siennicki, J.
    Raciborska, I.
    Kovacevic-Kusmierek, K.
    Chizynski, K.
    Kusmierek, J.
    Plachcinska, A.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2010, 37 : S263 - S264
  • [3] Prevalence of misregistration between SPECT and CT for attenuation-corrected myocardial perfusion SPECT
    Sibyll Goetze
    Richard L. Wahl
    Journal of Nuclear Cardiology, 2007, 14
  • [4] Prevalence of misregistration between SPECT and CT for attenuation-corrected myocardial perfusion SPECT
    Goetze, Sibyll
    Wahl, Richard L.
    JOURNAL OF NUCLEAR CARDIOLOGY, 2007, 14 (02) : 200 - 206
  • [5] Comparative Accuracy of CT Attenuation-Corrected and Non-Attenuation-Corrected SPECT Myocardial Perfusion Imaging
    Sharma, Punit
    Patel, Chetan D.
    Karunanithi, Sellam
    Maharjan, Sagar
    Malhotra, Arun
    CLINICAL NUCLEAR MEDICINE, 2012, 37 (04) : 332 - 338
  • [6] Adenosine stress myocardial perfusion detected with CT compared with attenuation-corrected SPECT
    Engvall, J. E.
    Gjerde, M.
    De Geer, J.
    Olsson, E.
    Quick, P.
    Persson, A.
    EUROPEAN HEART JOURNAL SUPPLEMENTS, 2011, 13 (0A) : A31 - A31
  • [7] Clinically significant abnormal findings on the "nondiagnostic" CT portion of low-amperage-CT attenuation-corrected myocardial perfusion SPECT/CT studies
    Goetze, Sibyll
    Pannu, Harpreet K.
    Wahl, Richard L.
    JOURNAL OF NUCLEAR MEDICINE, 2006, 47 (08) : 1312 - 1318
  • [8] Respiratory average CT for attenuation correction in myocardial perfusion SPECT/CT
    Duo Zhang
    Bang-Hung Yang
    Nien Yun Wu
    Greta Seng Peng Mok
    Annals of Nuclear Medicine, 2017, 31 : 172 - 180
  • [9] Respiratory average CT for attenuation correction in myocardial perfusion SPECT/CT
    Zhang, Duo
    Yang, Bang-Hung
    Wu, Nien Yun
    Mok, Greta Seng Peng
    ANNALS OF NUCLEAR MEDICINE, 2017, 31 (02) : 172 - 180
  • [10] Respiration Average CT for Myocardial Perfusion SPECT/CT Attenuation Correction
    Mok, Greta S. P.
    Zhang, Duo
    Ho, Cobie Y. T.
    2014 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2014,