Chemometric Strategies for Fully Automated Interpretive Method Development in Liquid Chromatography

被引:23
|
作者
Bos, Tijmen S. [1 ,2 ]
Boelrijk, Jim [2 ,3 ,4 ]
Molenaar, Stef R. A. [2 ,5 ]
Veer, Brian van 't [2 ,5 ]
Niezen, Leon E. [2 ,5 ]
van Herwerden, Denice [2 ,5 ]
Samanipour, Saer [2 ,5 ]
Stoll, Dwight R. [6 ]
Forre, Patrick [3 ,4 ]
Ensing, Bernd [4 ,7 ]
Somsen, Govert W. [1 ,2 ]
Pirok, Bob W. J. [2 ,4 ,5 ,6 ]
机构
[1] Vrije Univ Amsterdam, Amsterdam Inst Mol & Life Sci, Div Bioanalyt Chem, NL-1081 HV Amsterdam, Netherlands
[2] Ctr Analyt Sci Amsterdam CASA, NL-1098 XH Amsterdam, Netherlands
[3] Univ Amsterdam, Informat Inst, AMLab, NL-1098 XH Amsterdam, Netherlands
[4] Univ Amsterdam, AI4Sci Lab, NL-1098 XH Amsterdam, Netherlands
[5] Univ Amsterdam, Vant Hoff Inst Mol Sci, Analyt Chem Grp, NL-1098 XH Amsterdam, Netherlands
[6] Gustavus Adolphus Coll, Dept Chem, St Peter, MN 56082 USA
[7] Univ Amsterdam, Vant Hoff Inst Mol Sci, Computat Chem Grp, NL-1098 XH Amsterdam, Netherlands
基金
荷兰研究理事会;
关键词
MULTIOBJECTIVE OPTIMIZATION; CLOSED-LOOP; PERFORMANCE; SPECTROMETRY; SIMULATION; SEPARATION; SERUM; TIME;
D O I
10.1021/acs.analchem.2c03160
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The majority of liquid chromatography (LC) methods are still developed in a conventional manner, that is, by analysts who rely on their knowledge and experience to make method development decisions. In this work, a novel, open-source algorithm was developed for automated and interpretive method development of LC(-mass spectrometry) separations ("AutoLC"). A closed-loop workflow was constructed that interacted directly with the LC system and ran unsupervised in an automated fashion. To achieve this, several challenges related to peak tracking, retention modeling, the automated design of candidate gradient profiles, and the simulation of chromatograms were investigated. The algorithm was tested using two newly designed method development strategies. The first utilized retention modeling, whereas the second used a Bayesianoptimization machine learning approach. In both cases, the algorithm could arrive within 4-10 iterations (i.e., sets of method parameters) at an optimum of the objective function, which included resolution and analysis time as measures of performance. Retention modeling was found to be more efficient while depending on peak tracking, whereas Bayesian optimization was more flexible but limited in scalability. We have deliberately designed the algorithm to be modular to facilitate compatibility with previous and future work (e.g., previously published data handling algorithms).
引用
收藏
页码:16060 / 16068
页数:9
相关论文
共 50 条
  • [31] Use of desirability functions associated with a chemometric method to optimize separation of a compound mixture by liquid chromatography
    Guillaume, Y
    Peyrin, E
    Guinchard, C
    JOURNAL OF AOAC INTERNATIONAL, 1997, 80 (02) : 436 - 438
  • [32] Chemometric Optimization of QuEChERS Extraction Method for Polyphenol Determination in Beers by Liquid Chromatography with Ultraviolet Detection
    Oscar Galarce-Bustos
    Lissette Novoa
    Jessy Pavon-Perez
    Karem Henriquez-Aedo
    Mario Aranda
    Food Analytical Methods, 2019, 12 : 448 - 457
  • [33] FULLY AUTOMATED SAMPLE HANDLING-SYSTEM FOR LIQUID-CHROMATOGRAPHY BASED ON PRECOLUMN TECHNOLOGY AND AUTOMATED CARTRIDGE EXCHANGE
    NIELEN, MWF
    VALK, AJ
    FREI, RW
    BRINKMAN, UAT
    MUSSCHE, P
    DENIJS, R
    OOMS, B
    SMINK, W
    JOURNAL OF CHROMATOGRAPHY, 1987, 393 (01): : 69 - 83
  • [34] Chemometric Optimization of QuEChERS Extraction Method for Polyphenol Determination in Beers by Liquid Chromatography with Ultraviolet Detection
    Galarce-Bustos, Oscar
    Novoa, Lissette
    Pavon-Perez, Jessy
    Henriquez-Aedo, Karem
    Aranda, Mario
    FOOD ANALYTICAL METHODS, 2019, 12 (02) : 448 - 457
  • [35] RAPID MEASUREMENT OF SERUM CORTISOL BY FULLY AUTOMATED HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY
    NOZAKI, O
    OHATA, T
    OHBA, Y
    MORIYAMA, H
    KATO, Y
    CLINICAL CHEMISTRY, 1988, 34 (06) : 1217 - 1217
  • [36] Fully automated liquid chromatography-mass spectrometry determination of 17β-estradiol in river water
    Watabe, Yoshiyuki
    Kubo, Takuya
    Nishikawa, Teppei
    Fujita, Tomio
    Kaya, Kunimitsu
    Hosoya, Ken
    JOURNAL OF CHROMATOGRAPHY A, 2006, 1120 (1-2) : 252 - 259
  • [37] Fully automated workstation for liquid - Liquid equilibrium measurements
    Kuzmanovic, B
    van Delden, ML
    Kuipers, NJM
    de Haan, AB
    JOURNAL OF CHEMICAL AND ENGINEERING DATA, 2003, 48 (05): : 1237 - 1244
  • [38] A fully automated on-line preconcentration and liquid chromatography-tandem mass spectrometry method for the analysis of anti-infectives in wastewaters
    Segura, Pedro A.
    Gagnon, Christian
    Sauve, Sebastien
    ANALYTICA CHIMICA ACTA, 2007, 604 (02) : 147 - 157
  • [39] Determination of linezolid in plasma and bronchoalveolar lavage by high-performance liquid chromatography with ultraviolet detection using a fully automated extraction method
    Toutain, J
    Boselli, E
    Djabarouti, S
    Allaouchiche, B
    Xuereb, F
    Bernadou, JM
    Ba, B
    Saux, MC
    Breilh, D
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2004, 813 (1-2): : 145 - 150
  • [40] Chemometric Strategies for Peak Detection and Profiling from Multidimensional Chromatography
    Navarro-Reig, Meritxell
    Bedia, Carmen
    Tauler, Roma
    Jaumot, Joaquim
    PROTEOMICS, 2018, 18 (18)