Chemometric Strategies for Fully Automated Interpretive Method Development in Liquid Chromatography

被引:23
|
作者
Bos, Tijmen S. [1 ,2 ]
Boelrijk, Jim [2 ,3 ,4 ]
Molenaar, Stef R. A. [2 ,5 ]
Veer, Brian van 't [2 ,5 ]
Niezen, Leon E. [2 ,5 ]
van Herwerden, Denice [2 ,5 ]
Samanipour, Saer [2 ,5 ]
Stoll, Dwight R. [6 ]
Forre, Patrick [3 ,4 ]
Ensing, Bernd [4 ,7 ]
Somsen, Govert W. [1 ,2 ]
Pirok, Bob W. J. [2 ,4 ,5 ,6 ]
机构
[1] Vrije Univ Amsterdam, Amsterdam Inst Mol & Life Sci, Div Bioanalyt Chem, NL-1081 HV Amsterdam, Netherlands
[2] Ctr Analyt Sci Amsterdam CASA, NL-1098 XH Amsterdam, Netherlands
[3] Univ Amsterdam, Informat Inst, AMLab, NL-1098 XH Amsterdam, Netherlands
[4] Univ Amsterdam, AI4Sci Lab, NL-1098 XH Amsterdam, Netherlands
[5] Univ Amsterdam, Vant Hoff Inst Mol Sci, Analyt Chem Grp, NL-1098 XH Amsterdam, Netherlands
[6] Gustavus Adolphus Coll, Dept Chem, St Peter, MN 56082 USA
[7] Univ Amsterdam, Vant Hoff Inst Mol Sci, Computat Chem Grp, NL-1098 XH Amsterdam, Netherlands
基金
荷兰研究理事会;
关键词
MULTIOBJECTIVE OPTIMIZATION; CLOSED-LOOP; PERFORMANCE; SPECTROMETRY; SIMULATION; SEPARATION; SERUM; TIME;
D O I
10.1021/acs.analchem.2c03160
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The majority of liquid chromatography (LC) methods are still developed in a conventional manner, that is, by analysts who rely on their knowledge and experience to make method development decisions. In this work, a novel, open-source algorithm was developed for automated and interpretive method development of LC(-mass spectrometry) separations ("AutoLC"). A closed-loop workflow was constructed that interacted directly with the LC system and ran unsupervised in an automated fashion. To achieve this, several challenges related to peak tracking, retention modeling, the automated design of candidate gradient profiles, and the simulation of chromatograms were investigated. The algorithm was tested using two newly designed method development strategies. The first utilized retention modeling, whereas the second used a Bayesianoptimization machine learning approach. In both cases, the algorithm could arrive within 4-10 iterations (i.e., sets of method parameters) at an optimum of the objective function, which included resolution and analysis time as measures of performance. Retention modeling was found to be more efficient while depending on peak tracking, whereas Bayesian optimization was more flexible but limited in scalability. We have deliberately designed the algorithm to be modular to facilitate compatibility with previous and future work (e.g., previously published data handling algorithms).
引用
收藏
页码:16060 / 16068
页数:9
相关论文
共 50 条
  • [1] Peak-Tracking Algorithm for Use in Automated Interpretive Method-Development Tools in Liquid Chromatography
    Pirok, Bob W. J.
    Molenaar, Stef R. A.
    Roca, Liana S.
    Schoenmakers, Peter J.
    ANALYTICAL CHEMISTRY, 2018, 90 (23) : 14011 - 14019
  • [2] Automated Liquid Chromatography Method Development Design and Practice
    Yanik, Gary W.
    AMERICAN LABORATORY, 2016, 48 (07) : 19 - 21
  • [3] Chemometric-assisted method development in reversed-phase liquid chromatography
    Cela, R.
    Ordonez, E. Y.
    Quintana, J. B.
    Rodil, R.
    JOURNAL OF CHROMATOGRAPHY A, 2013, 1287 : 2 - 22
  • [4] Chemometric-assisted method development in hydrophilic interaction liquid chromatography: A review
    Taraji, Maryam
    Haddad, Paul R.
    Amos, Ruth I. J.
    Talebi, Mohammad
    Szucs, Roman
    Dolan, John W.
    Pohl, Christopher A.
    ANALYTICA CHIMICA ACTA, 2018, 1000 : 20 - 40
  • [5] Automated method development in high-pressure liquid chromatography
    Bosten, Emery
    Kensert, Alexander
    Desmet, Gert
    Cabooter, Deirdre
    JOURNAL OF CHROMATOGRAPHY A, 2024, 1714
  • [6] Automated method development in high-performance liquid chromatography
    Snyder, LR
    HIGH RESOLUTION SEPARATION AND ANALYSIS OF BIOLOGICAL MACROMOLECULES, PT A: FUNDAMENTALS, 1996, 270 : 151 - 175
  • [7] Application of chemometric approach for development and validation of high performance liquid chromatography method for estimation of ropinirole hydrochloride
    Fatima, Saman
    Beg, Sarwar
    Samim, Mohammed
    Ahmad, Farhan J.
    JOURNAL OF SEPARATION SCIENCE, 2019, 42 (21) : 3293 - 3301
  • [8] A new, rapid, fully automated method for determination of fluconazole in serum by column-switching liquid chromatography
    Egle, H
    Trittler, R
    Kümmerer, K
    THERAPEUTIC DRUG MONITORING, 2004, 26 (04) : 425 - 431
  • [9] Systematic Strategies in High-Performance Liquid Chromatography Method Development and Validation
    Shabir, Ghulam A.
    SEPARATION SCIENCE AND TECHNOLOGY, 2010, 45 (05) : 670 - 680
  • [10] Fully automated minicolumn chromatography
    Murray, Brian
    Bhat, Diya
    Bhadouria, Arjun
    Walther, Jason
    Brower, Kevin
    JOURNAL OF CHROMATOGRAPHY A, 2023, 1712