Cardiac magnetic resonance derived atrial function in patients with a Fontan circulation

被引:7
|
作者
Critser, Paul J. [1 ]
Truong, Vien [3 ]
Powell, Adam W. [1 ,2 ]
Almeneisi, Hassan [1 ]
Opotowsky, Alexander R. [1 ,2 ]
Ollberding, Nicholas J. [2 ,4 ]
Gandhi, Janvi [1 ]
Lubert, Adam M. [1 ,2 ]
Mazur, Wojciech [3 ]
Lang, Sean M. [1 ,2 ]
Tretter, Justin T. [1 ,2 ]
Taylor, Michael D. [1 ,2 ]
Alsaied, Tarek [1 ,2 ]
机构
[1] Cincinnati Childrens Hosp Med Ctr, Inst Heart, Cincinnati, OH 45229 USA
[2] Univ Cincinnati, Coll Med, Dept Pediat, Cincinnati, OH USA
[3] Christ Hosp Hlth Network, Cincinnati, OH USA
[4] Cincinnati Childrens Hosp Med Ctr, Div Biostat & Epidemiol, Cincinnati, OH 45229 USA
来源
关键词
Fontan; Cardiac magnetic resonance; Atrial function; Congenital heart disease; Hemodynamics; SPECKLE-TRACKING; FREE SURVIVAL; ECHOCARDIOGRAPHY; OPERATION; FORCE;
D O I
10.1007/s10554-020-01959-6
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
To assess atrial function in Fontan patients using cardiac MRI (CMR) and determine the relationships between atrial function, hemodynamics, and clinical outcomes. Two center chart review identified all Fontan patients with technically adequate CMR to assess atrial function within 1 year of cardiac catheterization and age-matched controls with CMR. Atrial reservoir, conduit, and pump global longitudinal strain and strain rate measurements were determined by CMR. Univariate and stepwise multivariable analysis were conducted to detect associations of atrial function measures with ventricular end diastolic pressure (EDP), cardiac index (CI), exercise capacity, liver stiffness and a composite outcome of heart transplantation, ventricular assist device or death. The study cohort was comprised of 33 Fontan patients and 30 age-matched controls. Fontan patients had lower atrial reservoir and conduit strain, and lower reservoir, conduit, and pump strain rate compared to age-matched controls. Atrial conduit strain was negatively associated with EDP and lower atrial pump-to-conduit strain ratio was associated with lower cardiac index in multivariable analysis. Lower atrial pump strain was associated with lower exercise capacity (per 1% increase: beta = 2.3 +/- 0.9, p = 0.03) and higher liver stiffness (per 1% increase: beta = - 0.12 +/- 0.03, p = 0.002). Higher atrial pump strain (HR per 1% increase = 0.53 [95% confidence interval 0.22, 0.83], p = 0.002) and ventricular ejection fraction (HR per 1% increase = 0.90 [95% confidence interval 0.80, 0.98], p = 0.02) were associated with lower risk for the composite adverse outcome. Atrial function is impaired in Fontan patients and is associated with worse CI, EDP, exercise performance, liver stiffness, and a higher risk for adverse outcomes.
引用
收藏
页码:275 / 284
页数:10
相关论文
共 50 条
  • [41] Decreased Diastolic Ventricular Kinetic Energy in Young Patients with Fontan Circulation Demonstrated by Four-Dimensional Cardiac Magnetic Resonance Imaging
    Sjoberg, Pia
    Heiberg, Einar
    Wingren, Par
    Johansson, Jens Ramgren
    Malm, Torsten
    Arheden, Hakan
    Liuba, Petru
    Carlsson, Marcus
    PEDIATRIC CARDIOLOGY, 2017, 38 (04) : 669 - 680
  • [42] Morphology and Function of the Lymphatic Vasculature in Patients With a Fontan Circulation
    Mohanakumar, Sheyanth
    Telinius, Niklas
    Kelly, Benjamin
    Lauridsen, Henrik
    Boedtkjer, Donna
    Pedersen, Michael
    de Leval, Marc
    Hjortdal, Vibeke
    CIRCULATION-CARDIOVASCULAR IMAGING, 2019, 12 (04) : e008074
  • [43] Inefficient Ventriculoarterial Coupling in Fontan Patients Measured Noninvasively Using Cardiac Magnetic Resonance
    Godfrey, Max E.
    Rathod, Rahul H.
    Keenan, Ellen M.
    Geva, Tal
    Gauvreau, Kimberlee
    Powell, Andrew J.
    Prakash, Ashwin
    CIRCULATION, 2015, 132
  • [44] Left Atrial Phasic Function via Cardiac Magnetic Resonance Imaging in Patients with Duchenne Muscular Dystrophy
    Trussell, Taylor M.
    Brown, Tyler
    Marcuccio, Elisa
    Mullikin, Anna
    Zang, Huaiyu
    Ollberding, Nicholas J.
    Villa, Chet
    Lang, Sean M.
    PEDIATRIC CARDIOLOGY, 2025, 46 (01) : 72 - 80
  • [45] EFFECTS OF ATRIAL FIBRILLATION ABLATION ON LEFT ATRIAL FUNCTION AS EVALUATED ON CARDIAC MAGNETIC RESONANCE IMAGING
    Moulki, Naeem
    Waqar, Aneeq
    Schoenecker, Nancy
    Joyce, Cara
    Syed, Mushabbar A.
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2020, 75 (11) : 280 - 280
  • [46] Impact of Atrial Fibrillation on Fontan Circulation: Fontan Computational Model
    Sughimoto, Koichi
    Ueda, Tetsuya
    Fujiwara, Takashi
    Kabasawa, Masashi
    Liu, Hao
    ANNALS OF THORACIC SURGERY, 2022, 114 (04): : 1460 - 1467
  • [47] Cardiac function in pregnant women with a Fontan circulation following live birth
    Lodge, F.
    Castleman, J.
    Fox, C.
    Morris, R. K.
    Ram, C.
    Clift, R.
    Hudsmith, L.
    EUROPEAN HEART JOURNAL, 2020, 41 : 3181 - 3181
  • [48] Hypogammaglobinemia in Patients Palliated with the Fontan Circulation: Implications for Cardiac Transplantation
    Margolin, E. A.
    Adler, E. D.
    Alshawabkeh, L.
    Riedl, M. A.
    Urey, M. A.
    JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2022, 41 (04): : S436 - S436
  • [49] Liver Strain Using Feature Tracking of Cine Cardiac Magnetic Resonance Imaging: Assessment of Liver Dysfunction in Patients with Fontan Circulation and Tetralogy of Fallot
    Ohashi, Ryoko
    Nagao, Michinobu
    Ishizaki, Umiko
    Shiina, Yumi
    Inai, Kei
    Sakai, Shuji
    PEDIATRIC CARDIOLOGY, 2020, 41 (02) : 389 - 397
  • [50] Liver Strain Using Feature Tracking of Cine Cardiac Magnetic Resonance Imaging: Assessment of Liver Dysfunction in Patients with Fontan Circulation and Tetralogy of Fallot
    Ryoko Ohashi
    Michinobu Nagao
    Umiko Ishizaki
    Yumi Shiina
    Kei Inai
    Shuji Sakai
    Pediatric Cardiology, 2020, 41 : 389 - 397