Metrological challenges of Synchrotron Radiation Optics

被引:18
|
作者
Sostero, G [1 ]
Cocco, D [1 ]
Qian, SN [1 ]
机构
[1] Sincrotrone Trieste, I-34012 Trieste, Italy
来源
关键词
profilometry; optical metrology; surface metrology; x-ray optics; LTP;
D O I
10.1117/12.360158
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Modern third generation storage rings, require state-of-the-art grazing incidence x-ray optics, in order to monochromate the Synchrotron Radiation (SR) source photons, and focus them into the experimental stations. Slope error tolerances in the order of 0.5 mu Rad RMS, and surface roughness well below 5 Angstrom RMS, are frequently specified for mirrors and gratings exceeding 300 mm in length. Non-contact scanning instruments were developed, in order to characterise SR optical surfaces, of spherical and aspherical shape. Among these, the Long Trace Profiler (LTP), a double pencil slope measuring interferometer, has proved to be particularly reliable, and was adopted by several SR optics metrology laboratories. The ELETTRA soft x-rays and optics metrology laboratory, has operated an LTP since 1992. We review the basic operating principles of this instrument, and some major instrumental and environmental improvements, that were developed in order to detect slope errors lower than 1 mu Rad RMS on optical surfaces up to one metre in length. A comparison among measurements made on the same reference flat, by different interferometers (most of them were LTPs) can give some helpful indications in order to optimise the quality of measurement.
引用
收藏
页码:310 / 316
页数:7
相关论文
共 50 条
  • [31] FOCUSING OPTICS FOR A SYNCHROTRON X-RADIATION MICROPROBE
    ICE, GE
    SPARKS, CJ
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1984, 222 (1-2): : 121 - 127
  • [32] Mössbauer optics of synchrotron radiation at an isotopic boundary
    V. A. Belaykov
    S. V. Semenov
    Journal of Experimental and Theoretical Physics, 2000, 90 : 290 - 300
  • [33] Nanofocusing optics for synchrotron radiation made from polycrystalline diamond
    Fox, O. J. L.
    Alianelli, L.
    Malik, A. M.
    Pape, I.
    May, P. W.
    Sawhney, K. J. S.
    OPTICS EXPRESS, 2014, 22 (07): : 7657 - 7668
  • [34] SUMMARY OF THE SATELLITE WORKSHOP ON THERMAL PROBLEMS OF SYNCHROTRON RADIATION OPTICS
    FREUND, AK
    MILLS, DM
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1992, 63 (01): : 1623 - 1624
  • [35] POLARIZATION PHENOMENA IN X-RAY OPTICS OF SYNCHROTRON RADIATION
    BELYAKOV, VA
    DMITRIENKO, VE
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1989, 282 (2-3): : 526 - 528
  • [36] Surface metrology of X-ray optics for synchrotron radiation
    Ohashi H.
    Seimitsu Kogaku Kaishi/Journal of the Japan Society for Precision Engineering, 2010, 76 (11): : 1239 - 1243
  • [37] Graded X-ray optics for synchrotron radiation applications
    J. Synchrotron Radiat., 3 (239-245):
  • [38] MULTILAYER X-RAY OPTICS FOR SYNCHROTRON-RADIATION
    SALASHCHENKO, NN
    PLATONOV, YY
    ZUEV, SY
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1995, 359 (1-2): : 114 - 120
  • [39] Graded X-ray optics for synchrotron radiation applications
    Erko, A
    Veldkamp, M
    Gudat, W
    Abrosimov, NV
    Rossolenko, SN
    Shekhtman, V
    Khasanov, S
    Alex, V
    Groth, S
    Schroder, W
    Vidal, B
    Yakshin, A
    JOURNAL OF SYNCHROTRON RADIATION, 1998, 5 : 239 - 245
  • [40] IMAGE CONVERSION OF σ- AND π-COMPONENTS OF RADIATION OF RELATIVISTIC ELECTRON AND METROLOGICAL CHARACTERISTICS OF THE PHOTON FLUX IN THE SYNCHROTRON RADIATION OUTLET
    Mazmanishvili, A. S.
    Moskalets, N., V
    Shcherbakov, A. A.
    PROBLEMS OF ATOMIC SCIENCE AND TECHNOLOGY, 2021, (06): : 160 - 164