Closed-Loop Delivery Systems Versus Manually Controlled Administration of Total IV Anesthesia: A Meta-analysis of Randomized Clinical Trials

被引:95
|
作者
Pasin, Laura [1 ]
Nardelli, Pasquale [1 ]
Pintaudi, Margherita [1 ]
Greco, Massimiliano [1 ]
Zambon, Massimo [1 ]
Cabrini, Luca [1 ]
Zangrillo, Alberto [1 ]
机构
[1] IRCCS San Raffaele Sci Inst, Dept Anesthesia & Intens Care, Via Olgettina 60, I-20132 Milan, Italy
来源
ANESTHESIA AND ANALGESIA | 2017年 / 124卷 / 02期
关键词
QUANTITATIVE EEG-ANALYSIS; BISPECTRAL INDEX; FEEDBACK-CONTROL; PROPOFOL; TITRATION; FEASIBILITY; MORTALITY; SURGERY; INDUCTION;
D O I
10.1213/ANE.0000000000001394
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Bispectral Index Scale (BIS)-guided closed-loop delivery of anesthetics has been extensively studied. We performed a meta-analysis of all the randomized clinical trials comparing efficacy and performance between BIS-guided closed-loop delivery and manually controlled administration of total IV anesthesia. Scopus, PubMed, EMBASE, and the Cochrane Central Register of clinical trials were searched for pertinent studies. Inclusion criteria were random allocation to treatment and closed-loop delivery systems versus manually controlled administration of total IV anesthesia in any surgical setting. Exclusion criteria were duplicate publications and nonadult studies. Twelve studies were included, randomly allocating 1284 patients.. Use of closed-loop anesthetic delivery systems was associated with a significant reduction in the dose of propofol administered for induction of anesthesia (mean difference [MD] = 0.37 [0.17-0.57], P for effect <0.00001, P for heterogeneity = 0.001, I-2 = 74%) and a significant reduction in recovery time (MD = 1.62 [0.60-2.64], P for effect <0.0001, P for heterogeneity = 0.06, I-2 = 47%). The target depth of anesthesia was preserved more frequently with closed-loop anesthetic delivery than with manual control (MD = 15.17 [-23.11 to -7.24], P for effect <0.00001, P for heterogeneity <0.00001, I-2 = 83%). There were no differences in the time required to induce anesthesia and the total propofol dose. Closed-loop anesthetic delivery performed better than manual-control delivery. Both median absolute performance error and wobble index were significantly lower in closed-loop anesthetic delivery systems group (MD = 5.82 [3.17-8.46], P for effect <0.00001, P for heterogeneity <0.00001, I-2 = 90% and MD = 0.92 [0.13-1.72], P for effect = 0.003, P for heterogeneity = 0.07, I-2 = 45%). When compared with manual control, BIS-guided anesthetic delivery of total IV anesthesia reduces propofol requirements during induction, better maintains a target depth of anesthesia, and reduces recovery time.
引用
收藏
页码:456 / 464
页数:9
相关论文
共 50 条
  • [1] Clinical Performance and Safety of Closed-Loop Systems: A Systematic Review and Meta-analysis of Randomized Controlled Trials
    Brogi, Etrusca
    Cyr, Shantale
    Kazan, Roy
    Giunta, Francesco
    Hemmerling, Thomas M.
    [J]. ANESTHESIA AND ANALGESIA, 2017, 124 (02): : 446 - 455
  • [2] Performance of closed-loop systems for intravenous drug administration: a systematic review and meta-analysis of randomised controlled trials
    Ana Spataru
    Paola Eiben
    Annette Pluddemann
    [J]. Journal of Clinical Monitoring and Computing, 2024, 38 : 5 - 18
  • [3] Performance of closed-loop systems for intravenous drug administration: a systematic review and meta-analysis of randomised controlled trials
    Spataru, Ana
    Eiben, Paola
    Pluddemann, Annette
    [J]. JOURNAL OF CLINICAL MONITORING AND COMPUTING, 2024, 38 (01) : 5 - 18
  • [4] A Multicenter Evaluation of a Closed-Loop Anesthesia Delivery System: A Randomized Controlled Trial
    Puri, Goverdhan D.
    Mathew, Preethy J.
    Biswas, Indranil
    Dutta, Amitabh
    Sood, Jayashree
    Gombar, Satinder
    Palta, Sanjeev
    Tsering, Morup
    Gautam, P. L.
    Jayant, Aveek
    Arora, Inderjeet
    Bajaj, Vishal
    Punia, T. S.
    Singh, Gurjit
    [J]. ANESTHESIA AND ANALGESIA, 2016, 122 (01): : 106 - 114
  • [5] Bispectral index monitoring of the clinical effects of propofol closed-loop target-controlled infusion Systematic review and meta-analysis of randomized controlled trials
    Wang, Danyang
    Song, Zichen
    Zhang, Chunlu
    Chen, Peng
    [J]. MEDICINE, 2021, 100 (04)
  • [6] Topical Anesthesia versus Regional Anesthesia for Cataract Surgery: A Meta-Analysis of Randomized Controlled Trials
    Zhao, Li-Quan
    Zhu, Huang
    Zhao, Pei-Quan
    Wu, Qi-Rong
    Hu, Yi-Qian
    [J]. OPHTHALMOLOGY, 2012, 119 (04) : 659 - 667
  • [7] A comparison of regional versus general anesthesia for ambulatory anesthesia: A meta-analysis of randomized controlled trials
    Liu, SS
    Strodtbeck, WM
    Richman, JM
    Wu, CL
    [J]. ANESTHESIA AND ANALGESIA, 2005, 101 (06): : 1634 - 1642
  • [8] Does fully closed-loop automated insulin delivery improve glycaemic control in patients with type 2 diabetes? A meta-analysis of randomized controlled trials
    Amer, Basma Ehab
    Yaqout, Yasmeen Essam
    Abozaid, Ahmed Mohamed
    Afifi, Eslam
    Aboelkhier, Menna M.
    [J]. DIABETIC MEDICINE, 2024, 41 (01)
  • [9] Closed-suction drainage versus no drainage in total hip arthroplasty, a meta-analysis of randomized controlled trials
    Zan, Pengfei
    Wang, Weifeng
    Fan, Lin
    Wu, Zhong
    Yu, Xiao
    Xu, Tianyang
    Li, Guodong
    [J]. INTERNATIONAL JOURNAL OF CLINICAL AND EXPERIMENTAL MEDICINE, 2016, 9 (02): : 725 - 735
  • [10] Efficacy and safety of closed-loop insulin delivery versus sensor-augmented pump in the treatment of adults with type 1 diabetes: a systematic review and meta-analysis of randomized-controlled trials
    Z. Fang
    M. Liu
    J. Tao
    C. Li
    F. Zou
    W. Zhang
    [J]. Journal of Endocrinological Investigation, 2022, 45 : 471 - 481