Using Whelk-O® for chiral method development in normal and reverse phase

被引:0
|
作者
Mannerino, F [1 ]
Szczerba, T [1 ]
Sardone, T [1 ]
机构
[1] Regis Technol Inc, Morton Grove, IL 60053 USA
关键词
D O I
暂无
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Chirality has become vitally important in the pharmaceutical, chemical, and agricultural industries. The differences that make compounds chiral can produce critically different pharmacological effects in biological systems. As a result, demand for stereoselective separation techniques and analytical assays to evaluate purity of chiral compounds has increased Chiral chromatography has become a necessary tool, not only for the analytical determination of enantiomeric purity, but also for the isolation of pure enantiomers.
引用
收藏
页码:28 / 28
页数:1
相关论文
共 50 条
  • [21] Chiral mixed matrix membranes with the (S,S)-Whelk-O®1 selector supported on polyethersulfone/MCM-41
    Vedovello, Priscila
    Fernandes, Carla
    Tiritan, Maria Elizabeth
    Paranhos, Caio Marcio
    NEW JOURNAL OF CHEMISTRY, 2024, 48 (21) : 9522 - 9533
  • [22] Investigation of a broadly applicable chiral selector used in enantioselective chromatography (Whelk-O 1) as a chiral solvating agent for NMR determination of enantiomeric composition
    Koscho, ME
    Pirkle, WH
    TETRAHEDRON-ASYMMETRY, 2005, 16 (20) : 3345 - 3351
  • [23] Effect of system pressure in SFC method development on a Whelk-0®1 chiral stationary phase
    Szczerba, Ted
    Wrezel, Paul
    LC GC NORTH AMERICA, 2007, : 25 - 25
  • [24] Effect of system temperature in SFC method development on the whelk-0 1® chiral stationary phase
    Szczerba, T
    Wrezel, P
    LC GC NORTH AMERICA, 2006, : 26 - 26
  • [25] Molecular dynamics study of chiral recognition for the Whelk-O1 chiral stationary phase
    Zhao, C. F.
    Cann, N. M.
    ANALYTICAL CHEMISTRY, 2008, 80 (07) : 2426 - 2438
  • [26] Rational optimization of the Whelk-O1 chiral stationary phase using molecular dynamics simulations
    Zhao, C. F.
    Diemert, S.
    Cann, N. M.
    JOURNAL OF CHROMATOGRAPHY A, 2009, 1216 (32) : 5968 - 5978
  • [27] Solvation of the Whelk-O1 chiral stationary phase: A molecular dynamics study
    Zhao, Chunfeng
    Cann, N. M.
    JOURNAL OF CHROMATOGRAPHY A, 2006, 1131 (1-2) : 110 - 129
  • [28] Expanding the potential of chiral chromatography for high-throughput screening of large compound libraries by means of sub-2 μm Whelk-O 1 stationary phase in supercritical fluid conditions
    Sciascera, Luca
    Ismail, Omar
    Ciogli, Alessia
    Kotoni, Dorina
    Cavazzini, Alberto
    Botta, Lorenzo
    Szczerba, Ted
    Kocergin, Jelena
    Villani, Claudio
    Gasparrini, Francesco
    JOURNAL OF CHROMATOGRAPHY A, 2015, 1383 : 160 - 168
  • [29] New chiral reverse phase HPLC method for enantioselective analysis of ketorolac using chiral AGP column
    Sunil K. Dubey
    Jangala Hemanth
    Chiranjeevi Venkatesh K.
    R.N. Saha
    S. Pasha
    Journal of Pharmaceutical Analysis, 2012, 2 (06) : 462 - 465
  • [30] The docking of chiral epoxides on the Whelk-O1 stationary phase: A molecular dynamics study
    Zhao, Chunfeng
    Cann, N. M.
    JOURNAL OF CHROMATOGRAPHY A, 2007, 1149 (02) : 197 - 218