Plasma glucose in screening for diabetes and pre-diabetes: how much is too much? Analysis of fasting plasma glucose and oral glucose tolerance test in Sri Lankans
被引:12
|
作者:
Katulanda, G. W.
论文数: 0引用数: 0
h-index: 0
机构:
Med Res Inst, Colombo 08, Sri LankaMed Res Inst, Colombo 08, Sri Lanka
Katulanda, G. W.
[1
]
Katulanda, P.
论文数: 0引用数: 0
h-index: 0
机构:
Univ Colombo, Dept Clin Med, Diabet Res Unit, Fac Med, Colombo, Sri Lanka
Univ Oxford, Harris Manchester Univ, Oxford, England
Oxford Ctr Diabet Endocrinol & Metab, London, EnglandMed Res Inst, Colombo 08, Sri Lanka
Katulanda, P.
[2
,3
,4
]
Dematapitiya, C.
论文数: 0引用数: 0
h-index: 0
机构:
Univ Colombo, Dept Clin Med, Diabet Res Unit, Fac Med, Colombo, Sri LankaMed Res Inst, Colombo 08, Sri Lanka
Dematapitiya, C.
[2
]
Dissanayake, H. A.
论文数: 0引用数: 0
h-index: 0
机构:
Univ Colombo, Dept Clin Med, Diabet Res Unit, Fac Med, Colombo, Sri LankaMed Res Inst, Colombo 08, Sri Lanka
Dissanayake, H. A.
[2
]
Wijeratne, S.
论文数: 0引用数: 0
h-index: 0
机构:
Univ Colombo, Fac Med, Colombo, Sri LankaMed Res Inst, Colombo 08, Sri Lanka
Wijeratne, S.
[5
]
Sheriff, M. H. R.
论文数: 0引用数: 0
h-index: 0
机构:
Univ Colombo, Dept Clin Med, Diabet Res Unit, Fac Med, Colombo, Sri LankaMed Res Inst, Colombo 08, Sri Lanka
Sheriff, M. H. R.
[2
]
Matthews, D. R.
论文数: 0引用数: 0
h-index: 0
机构:
Oxford Ctr Diabet Endocrinol & Metab, London, EnglandMed Res Inst, Colombo 08, Sri Lanka
Matthews, D. R.
[4
]
机构:
[1] Med Res Inst, Colombo 08, Sri Lanka
[2] Univ Colombo, Dept Clin Med, Diabet Res Unit, Fac Med, Colombo, Sri Lanka
[3] Univ Oxford, Harris Manchester Univ, Oxford, England
[4] Oxford Ctr Diabet Endocrinol & Metab, London, England
Fasting plasma glucose;
Diabetes;
pre-diabetes;
Sri Lanka;
South Asia;
DIAGNOSIS;
CUTOFF;
PREVALENCE;
PREDICTION;
ASSOCIATION;
POPULATION;
COMMUNITY;
GLYCEMIA;
CRITERIA;
VALUES;
D O I:
10.1186/s12902-019-0343-x
中图分类号:
R5 [内科学];
学科分类号:
1002 ;
100201 ;
摘要:
BackgroundFasting plasma glucose (FPG) is the most commonly used screening tool for diabetes in Sri Lanka. Cut-off values from American Diabetes Association recommendations are adopted in the absence of local data. We aimed to establish FPG cut offs for Sri Lankans to screen for diabetes and pre-diabetes.MethodsData on FPG and diabetes/pre-diabetes status were obtained from Sri Lanka Diabetes and Cardiovascular Study (SLDCS), a community based island wide observational study conducted in 2005-6. Sensitivity specificity and area under the ROC curve were calculated for different FPG values.ResultsStudy included 4014 community dwelling people after excluding people already on treatment for diabetes or pre-diabetes. Mean age was 45.3 (15) years and 60.4% were females. FPG cut off of 5.3mmol/L showed better sensitivity and specificity than 5.6mmol/L in detecting diabetes (87.8% and 84.4% Vs 80.8% and 92.1%) and pre-diabetes (54.7% and 87.0% Vs 43.8% and 94.2%).Conclusions A lower FPG cut off of 5.3mmol/L has a better sensitivity and acceptable specificity in screening for diabetes and pre-diabetes in Sri Lankan adults.