Pixelated photon counting semiconductor X-ray detectors like the Medipix feature adjustable energy thresholds allowing selective counting of photons of a specified energy. This enables energy selective X-ray imaging with advanced material information. Furthermore the photon counting function principle of these detectors enables almost noiseless X-ray imaging providing a high contrast in low contrast objects. The aim of this study is to analyze the stability of the new Medipix3 detector especially in relation to flatfield correction for X-ray imaging applications and to present its use for high resolution low contrast X-ray imaging, and for energy selective X-ray imaging as well.
引用
收藏
页码:3846 / 3851
页数:6
相关论文
共 50 条
  • [21] X-Ray Fluorescence Imaging With the Medipix2 Single-Photon Counting Detector
    Uher, J.
    Harvey, G.
    Jakubek, J.
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2012, 59 (01) : 54 - 61
  • [22] TESTS OF IMAGING WITH LOBSTER-EYE X-RAY OPTICS AND MEDIPIX2 DETECTOR
    Tichy, V.
    Sveda, L.
    Marsik, J.
    Jakubek, J.
    Marsikova, V.
    Pina, L.
    Hudec, R.
    Hromcik, M.
    BALTIC ASTRONOMY, 2009, 18 (3-4) : 369 - 373
  • [23] Energy dispersive X-ray diffraction imaging
    Donges, Joern
    Rothkirch, Andre
    Wroblewski, Thomas
    Bjeoumikhov, Aniouar
    Scharf, Oliver
    Ordavo, Ivan
    Ihle, Sebastian
    MECHANICAL STRESS EVALUATION BY NEUTRONS AND SYNCHROTRON RADIATION VI, 2014, 772 : 21 - +
  • [24] Energy-resolved x-ray imaging
    Vasin, M. G.
    Ignatiev, Yu. V.
    Lakhtikov, A. E.
    Morovov, A. P.
    Nazarov, V. V.
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2007, 62 (6-7) : 648 - 653
  • [25] Energy response of imaging plate for X-ray
    Luo, Zhi-Ping
    Suzuki, C.
    Kosako, T.
    Ma, Ji-Zeng
    Yuanzineng Kexue Jishu/Atomic Energy Science and Technology, 2009, 43 (07): : 644 - 647
  • [26] Medical X-ray imaging with energy windowing
    Lindner, M
    Blanquart, L
    Fischer, P
    Krüger, H
    Wermes, N
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2001, 465 (01): : 229 - 234
  • [27] Reconstruction of X-ray spectra with the energy sensitive photon counting detector Medipix2
    Michel, Thilo
    Talla, Patrick Takoukam
    Firsching, Markus
    Durst, Juergen
    Boehnel, Michael
    Anton, Gisela
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2009, 598 (02): : 510 - 514
  • [28] Near optimal energy selective x-ray imaging system performance with simple detectors
    Alvarez, Robert E.
    MEDICAL PHYSICS, 2010, 37 (02) : 822 - 841
  • [29] Development of an X-ray imaging detector for high-energy X-ray microtomography
    Hoshino, Masato
    Uesugi, Kentaro
    Yagi, Naoto
    JOURNAL OF SYNCHROTRON RADIATION, 2020, 27 : 934 - 940
  • [30] Spectroscopy applications for the Medipix photon counting X-ray system
    Manuilskiy, A
    Norlin, B
    Nilsson, HE
    Fröjdh, C
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2004, 531 (1-2): : 251 - 257