Energy Selective X-Ray Imaging with Medipix

被引:0
|
作者
Procz, S. [1 ]
Luebke, J. [2 ]
Zwerger, A. [1 ]
Fauler, A. [1 ]
Pichotka, M. [1 ]
Mix, M. [2 ]
Fiederle, M. [1 ]
机构
[1] Freiburger Mat Forschungszentrum FMF, Stefan Meier Str 21, D-79104 Freiburg, Germany
[2] Univ Freiburg, D-79104 Freiberg, Germany
关键词
PIXEL READOUT CHIP; SINGLE; WORKING; SYSTEM;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Pixelated photon counting semiconductor X-ray detectors like the Medipix feature adjustable energy thresholds allowing selective counting of photons of a specified energy. This enables energy selective X-ray imaging with advanced material information. Furthermore the photon counting function principle of these detectors enables almost noiseless X-ray imaging providing a high contrast in low contrast objects. The aim of this study is to analyze the stability of the new Medipix3 detector especially in relation to flatfield correction for X-ray imaging applications and to present its use for high resolution low contrast X-ray imaging, and for energy selective X-ray imaging as well.
引用
收藏
页码:3846 / 3851
页数:6
相关论文
共 50 条
  • [1] X-ray energy selected imaging with Medipix II
    Ludwig, J
    Zwerger, A
    Benz, KW
    Fiederle, M
    Braml, H
    Fauler, A
    Konrath, JP
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2004, 531 (1-2): : 209 - 214
  • [2] Flatfield Correction Optimization for Energy Selective X-Ray Imaging With Medipix3
    Procz, S.
    Pichotka, M.
    Luebke, J.
    Hamann, E.
    Ballabriga, R.
    Blaj, G.
    Campbell, M.
    Fauler, A.
    Mix, M.
    Zwerger, A.
    Fiederle, M.
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2011, 58 (06) : 3182 - 3189
  • [3] Evaluation of X-ray phase-contrast imaging with the Medipix
    Bartl, P.
    Michel, T.
    Nachtrab, F.
    Uhlmann, N.
    Anton, G.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2011, 633 : S143 - S147
  • [4] Dose reductions in dental X-ray imaging using Medipix
    Watt, J
    Davidson, DW
    Johnston, C
    Smith, C
    Tlustos, L
    Mikulec, B
    Smith, KM
    Rahman, M
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2003, 513 (1-2): : 65 - 69
  • [5] Energy-Selective X-Ray Ghost Imaging
    何雨航
    张艾昕
    俞文凯
    陈黎明
    吴令安
    Chinese Physics Letters, 2020, 37 (04) : 86 - 89
  • [6] Energy-Selective X-Ray Ghost Imaging
    He, Yu-Hang
    Zhang, Ai-Xin
    Yu, Wen-Kai
    Chen, Li-Ming
    Wu, Ling-An
    CHINESE PHYSICS LETTERS, 2020, 37 (04)
  • [7] Dimensionality and noise in energy selective x-ray imaging
    Alvarez, Robert E.
    MEDICAL PHYSICS, 2013, 40 (11)
  • [8] Energy-Selective X-Ray Ghost Imaging
    何雨航
    张艾昕
    俞文凯
    陈黎明
    吴令安
    Chinese Physics Letters, 2020, (04) : 86 - 89
  • [9] Medipix 2 in X-ray diffraction
    de Vries, R. I.
    Weijers, S.
    Bethke, K.
    Kogan, V.
    Vasterink, J.
    Kharchenko, A.
    Fransen, M.
    Bethke, J.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2007, 576 (01): : 164 - 168
  • [10] X-ray and gamma imaging with Medipix and Timepix detectors in medical research
    Procz, S.
    Avila, C.
    Fey, J.
    Roque, G.
    Schuetz, M.
    Hamann, E.
    RADIATION MEASUREMENTS, 2019, 127