Characterizing the HeartMate II Left Ventricular Assist Device Outflow Using Particle Image Velocimetry

被引:7
|
作者
Rowlands, Grant W. [1 ]
Good, Bryan C. [1 ]
Deutsch, Steven [1 ]
Manning, Keefe B. [1 ,2 ]
机构
[1] Penn State Univ, Dept Biomed Engn, 205 Hallowell Bldg, University Pk, PA 16802 USA
[2] Penn State Hershey Med Ctr, Dept Surg, Hershey, PA 17033 USA
关键词
HeartMate II; Reynolds stresses; ventricular assist device; outlet cannula; particle image velocimetry; von Willebrand factor; fluid dynamics; VON-WILLEBRAND-FACTOR; SHEAR-STRESS; FLOW-FIELD; PUMP;
D O I
10.1115/1.4039822
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Ventricular assist devices (VADs) are implanted in patients with a diseased ventricle to maintain peripheral perfusion as a bridge-to-transplant or as destination therapy. However, some patients with continuous flow VADs (e.g., HeartMate II (HMII)) have experienced gastrointestinal (GI) bleeding, in part caused by the proteolytic cleavage or mechanical destruction of von Willebrand factor (vWF), a clotting glycoprotein. in vitro studies were performed to measure the flow located within the HMII outlet cannula under both steady and physiological conditions using particle image velocimetry (PIV). Under steady flow, a mock flow loop was used with the HMII producing a flow rate of 3.2 L/min. The physiological experiment included a pulsatile pump operated at 105 BPM with a ventricle filling volume of 50mL and in conjunction with the HMII producing a total flow rate of 5.0 L/min. Velocity fields, Reynolds normal stresses (RNSs), and Reynolds shear stresses (RSSs) were analyzed to quantify the outlet flow's potential contribution to vWF degradation. Under both flow conditions, the HMII generated principal Reynolds stresses that are, at times, orders of magnitude higher than those needed to unfurl vWF, potentially impacting its physiological function. Under steady flow, principal RNSs were calculated to be approximately 500 Pa in the outlet cannula. Elevated Reynolds stresses were observed throughout every phase of the cardiac cycle under physiological flow with principal RNSs approaching 1500 Pa during peak systole. Prolonged exposure to these conditions may lead to acquired von Willebrand syndrome (AvWS), which is accompanied by uncontrollable bleeding episodes.
引用
收藏
页数:13
相关论文
共 50 条
  • [31] EARLY EXPERIENCE WITH THE IMPLANTABLE HEARTMATE II LEFT VENTRICULAR ASSIST DEVICE
    Pektok, E.
    Cikirikcioglu, M.
    Kalangos, A.
    [J]. INTERNATIONAL JOURNAL OF ARTIFICIAL ORGANS, 2008, 31 (07): : 621 - 621
  • [32] Lidocaine toxicity in the setting of HeartMate II left ventricular assist device
    Tunney, R. K., Jr.
    Whyte, K.
    DeAntonio, H. J.
    [J]. JOURNAL OF CLINICAL PHARMACY AND THERAPEUTICS, 2018, 43 (05) : 733 - 736
  • [33] Low thromboembolic risk with the heartmate II left ventricular assist device
    John, R.
    Kamdar, F.
    Toninato, C.
    Boyle, A.
    Colvin-Adams, M.
    Liao, K.
    Miller, L.
    Joyce, L.
    [J]. JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2007, 26 (02): : S253 - S253
  • [34] Hybrid approach to HeartMate II left ventricular assist device exchange
    Timek, Tomasz A.
    Hooker, Robert L.
    Khaghani, Asghar
    Merhi, William
    [J]. JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2013, 145 (03): : 878 - 880
  • [35] Incidence of infection following HeartMate I and HeartMate II left ventricular assist device implantation
    Schaffer, J. M.
    Weiss, E. S.
    Patel, N. D.
    Russell, S. D.
    Shah, A. S.
    Conte, J. V.
    [J]. JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2008, 27 (02): : S133 - S134
  • [36] HeartMate® II left ventricular assist device:: a new device for advanced heart failure
    Delgado, Reynolds
    Bergheim, Marianne
    [J]. EXPERT REVIEW OF MEDICAL DEVICES, 2005, 2 (05) : 529 - 532
  • [37] Mechanical Device Malfunction of the HeartMate II Versus the HeartMate 3 Left Ventricular Assist Device: The Rotterdam Experience
    van der Heiden, Cornelis W.
    Zijderhand, Casper F.
    Veen, Kevin M.
    Constantinescu, Alina A.
    Manintveld, Olivier C.
    Brugts, Jasper J.
    Bekkers, Jos A.
    Birim, Ozcan
    Bogers, Ad J. J. C.
    Caliskan, Kadir
    [J]. ASAIO JOURNAL, 2023, 69 (02) : E80 - E85
  • [38] A prototype HeartQuest ventricular assist device for particle image velocimetry measurements
    Day, SW
    McDaniel, JC
    Wood, HG
    Allaire, PE
    Song, XW
    Lemire, PP
    Miles, SD
    [J]. ARTIFICIAL ORGANS, 2002, 26 (11) : 1002 - 1005
  • [39] Particle-Image Velocimetry Study of a Pediatric Ventricular Assist Device
    Ferrara, E.
    Muramatsu, M.
    Christensen, K. T.
    Cestari, I. A.
    [J]. JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 2010, 132 (07):
  • [40] Comparison of left ventricular geometry after HeartMate II and HeartWare left ventricular assist device implantation
    Hosseini, Morteza Tavakkoli
    Popov, Aron Frederik
    Simon, Andre Ruediger
    Amrani, Mohamed
    Bahrami, Toufan
    [J]. JOURNAL OF CARDIOTHORACIC SURGERY, 2013, 8