In vitro abrasion using an air-powder polishing device and its quantification by radiotracer measurement

被引:2
|
作者
Finke, CH
Radlanski, RJ
Gawlik, D
Brätter, P
Gatschke, W
Rabe, HH
Arens, B
Williams, S
机构
[1] Humboldt Univ, Dept Pediat Dent, Berlin, Germany
[2] Free Univ Berlin, Dept Expt Dent, D-1000 Berlin, Germany
[3] Hahn Meitner Inst Kernforsch Berlin GmbH, Dept Trace Elements Hlth & Nutr, D-1000 Berlin, Germany
关键词
abrasion; wear resistance; air-powder polishing; fissure sealant material; glass ionomer cement; neutron activation; radiotracer;
D O I
10.1016/S0109-5641(99)00030-5
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objectives. This study was conducted to examine the assessment of abrasion of two different materials after neutron activation. Methods. A fissure sealant material (Fissurit F/VOCO with a compressive strength of 235 MPa) and a glass ionomer cement (Aqua Ionofil/VOCO with a compressive strength of 170 MPa) were activated by irradiation with neutrons. Subsequent measurements of the full-energy-peak (FEP) (1368.55 keV of Na-24) were mode of the sample materials before and after abrasion via exposure to the air-powder polishing to accurately describe substance loss. Results. Abrasion varied more than three-fold between the two materials. Significance. Neutron activation and radiotracer measurement allows the quantification of abrasion effects in different materials. in comparison with other current methods its use may allow a superior measurement accuracy and precision in determining the abraded mass. (C) 1999 Academy of Dental Materials. Published by Elsevier Science Ltd. All rights reserved.
引用
收藏
页码:180 / 184
页数:5
相关论文
共 50 条
  • [41] An in vitro evaluation of selective demineralised enamel removal using bio-active glass air abrasion
    Avijit Banerjee
    Hiten Pabari
    George Paolinelis
    Ian D. Thompson
    Timothy F Watson
    Clinical Oral Investigations, 2011, 15 : 895 - 900
  • [42] IN-VITRO MEASUREMENT OF THE LOADS USING AN INSTRUMENTED SPINAL FIXATION DEVICE
    ROHLMANN, A
    EICK, O
    BERGMANN, G
    GRAICHEN, F
    ZEITSCHRIFT FUR ORTHOPADIE UND IHRE GRENZGEBIETE, 1995, 133 (02): : 136 - 140
  • [43] Subgingival plaque removal in buccal and lingual sites using a novel low abrasive air-polishing powder
    Petersilka, GJ
    Steinmann, D
    Häberlein, I
    Heinecke, A
    Flemmig, TF
    JOURNAL OF CLINICAL PERIODONTOLOGY, 2003, 30 (04) : 328 - 333
  • [44] Pilot study on the clinical and microbiological effect of subgingival glycine powder air polishing using a cannula-like jet
    Kargas, K.
    Tsalikis, L.
    Sakellari, D.
    Menexes, G.
    Konstantinidis, A.
    INTERNATIONAL JOURNAL OF DENTAL HYGIENE, 2015, 13 (03) : 161 - 169
  • [45] Standardized in vitro measurement of posterior capsule opacification using a modified scanning device
    Freisberg, L
    Hesse, L
    Kurz, C
    Kroll, P
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 1996, 37 (03) : 4124 - 4124
  • [46] Decontamination Using a Desiccant with Air Powder Abrasion Followed by Biphasic Calcium Sulfate Grafting: A New Treatment for Peri-Implantitis
    Lombardo, Giorgio
    Corrocher, Giovanni
    Rovera, Angela
    Pighi, Jacopo
    Marincola, Mauro
    Lehrberg, Jeffrey
    Nocini, Pier Francesco
    CASE REPORTS IN DENTISTRY, 2015, 2015
  • [47] Quantification of the specific membrane capacitance of single cells using a microfluidic device and impedance spectroscopy measurement
    Tan, Qingyuan
    Ferrier, Graham A.
    Chen, Brandon K.
    Wang, Chen
    Sun, Yu
    BIOMICROFLUIDICS, 2012, 6 (03):
  • [48] Clinical and microbiological effects of the supplementary use of an erythritol powder air-polishing device in non-surgical periodontal therapy: a randomized clinical trial
    Park, Eon-Jeong
    Kwon, Eun-Young
    Kim, Hyun-Joo
    Lee, Ju-Youn
    Choi, Jeomil
    Joo, Ji-Young
    JOURNAL OF PERIODONTAL AND IMPLANT SCIENCE, 2018, 48 (05): : 295 - 304
  • [49] Agar diffusion microbiological assay measurement using a smartphone device and its measurement uncertainty using the bootstrapping method
    Krapienis, Michelly Goncalves
    Lourenco, Felipe Rebello
    MICROCHEMICAL JOURNAL, 2024, 200
  • [50] PREDICTING PNEUMOTHORAX OUTCOME BY AIR LEAK MEASUREMENT: PILOT USING DIGITAL SUCTION DEVICE
    Hallifax, R. J.
    Corcoran, J. P.
    Rahman, N. M.
    THORAX, 2013, 68 : A174 - A175