Highly Sensitive Label-Free Electrochemical Aptasensor Based on Screen-Printed Electrode for Detection of Cadmium (II) Ions

被引:39
|
作者
Li, Yu [1 ]
Ran, Guojing [1 ]
Lu, Gen [2 ,3 ]
Ni, Xinyu [1 ]
Liu, Daling [2 ,3 ]
Sun, Jianxia [1 ]
Xie, Chunfang [2 ,3 ]
Yao, Dongsheng [2 ,3 ]
Bai, Weibin [1 ]
机构
[1] Jinan Univ, Inst Food Safety & Nutr, Dept Food Sci & Engn, Guangdong Engn Technol Ctr Food Safety Mol Rapid, Guangzhou 510632, Guangdong, Peoples R China
[2] Jinan Univ, Inst Microbial Technol, Guangzhou 510632, Guangdong, Peoples R China
[3] Jinan Univ, Natl Engn Res Ctr Med, Guangzhou 510632, Guangdong, Peoples R China
关键词
HEAVY-METAL IONS; VOLTAMMETRIC DETERMINATION; LEAD; NANOPARTICLES; SENSOR; EXPOSURE; APTAMER; COPPER(II); BIOSENSORS; COMPOSITE;
D O I
10.1149/2.0991906jes
中图分类号
O646 [电化学、电解、磁化学];
学科分类号
081704 ;
摘要
In this study, a simple but highly sensitive label-free aptasensor based on a screen-printed electrode (SPE) was developed for detection of Cd2+. As crucial biorecognizer, the Cd2+ aptamer (issAP08-Cd2+) was first screened out using the isothermal titration calorimetric method, which showed that the equilibrium dissociation constant (K-D) of Cd2+ binding with issAP08-Cd2+ was 2.9 mu M. Then, the issAP08-Cd2+, which is a single-stranded DNA with 25 nucleotides, was modified with thiol and assembled on gold screen-printed electrode. After that, the electrochemical aptasensor was used for Cd2+ detection by dropping Cd2+ solution on the SPE. The electrochemical properties were characterized by cyclic voltammetry (CV) and differential pulse voltammetry (DPV). Under the optimal conditions, the change of DPV peak currents density values (Lambda i) increased linearly with the logarithm of Cd2+ concentrations from 0.1 ng/mL to 1000 ng/mL. The regression coefficient was 0.9914 and the limit of detection (LOD) was 0.05 ng/mL (S/N = 3). This outcome supported the conclusion that the electrochemical aptasensor not only showed good sensitivity and selectivity but also obtained satisfactory reproducibility and stability results and performance on applications in real samples. More importantly, the composition of this aptasensor is very simple, and it has promising potential for rapid field detection of Cd2+. (C) 2019 The Electrochemical Society.
引用
收藏
页码:B449 / B455
页数:7
相关论文
共 50 条
  • [21] Label-free signal-on aptasensor for sensitive electrochemical detection of arsenite
    Cui, Lin
    Wu, Jie
    Ju, Huangxian
    BIOSENSORS & BIOELECTRONICS, 2016, 79 : 861 - 865
  • [22] A label-free electrochemical aptasensor for sensitive thrombin detection in whole blood
    Sun, Chong
    Wang, Xiaobo
    Yang, Xujie
    Xing, Lei
    Zhao, Bo
    Yang, Xiaodi
    Mao, Chun
    ELECTROCHIMICA ACTA, 2013, 106 : 327 - 332
  • [23] Screen-printed diamond electrode: A disposable sensitive electrochemical electrode
    Kondo, Takeshi
    Sakamoto, Hironori
    Kato, Takayoshi
    Horitani, Masaru
    Shitanda, Isao
    Itagaki, Masayuki
    Yuasa, Makoto
    ELECTROCHEMISTRY COMMUNICATIONS, 2011, 13 (12) : 1546 - 1549
  • [25] A highly sensitive graphene oxide based label-free capacitive aptasensor for vanillin detection
    Mohan, Hari Krishna Salila Vijayalal
    Chee, Wai Kit
    Li, Yida
    Nayak, Suryakanta
    Poh, Chueh Loo
    Thean, Aaron Voon Yew
    MATERIALS & DESIGN, 2020, 186
  • [26] Biolayer-Interferometry-Guided Functionalization of Screen-Printed Graphene for Label-Free Electrochemical Virus Detection
    Szydlowska, Beata M.
    Pola, Cicero C.
    Cai, Zizhen
    Chaney, Lindsay E.
    Hui, Janan
    Sheets, Robert
    Carpenter, Jeremiah
    Dean, Delphine
    Claussen, Jonathan C.
    Gomes, Carmen L.
    Hersam, Mark C.
    ACS APPLIED MATERIALS & INTERFACES, 2024, 16 (19) : 25169 - 25180
  • [27] Reusable potentiometric screen-printed sensor and label-free aptasensor with pseudo-reference electrode for determination of tryptophan in the presence of tyrosine
    Majidi, Mir Reza
    Omidi, Yadollah
    Karami, Pari
    Johari-Ahar, Mohammad
    TALANTA, 2016, 150 : 425 - 433
  • [28] An Aptasensor Based on a Flexible Screen-Printed Silver Electrode for the Rapid Detection of Chlorpyrifos
    Inam, A. K. M. Sarwar
    Angeli, Martina Aurora Costa
    Douaki, Ali
    Shkodra, Bajramshahe
    Lugli, Paolo
    Petti, Luisa
    SENSORS, 2022, 22 (07)
  • [29] Highly sensitive and selective optical detection of lead(II) using a label-free fluorescent aptasensor
    Huang, Yafei
    Yan, Jiao
    Fang, Zongzhuang
    Zhang, Chenghui
    Bai, Wenhui
    Yan, Mengmeng
    Zhu, Chao
    Gao, Chengguo
    Chen, Ailiang
    RSC ADVANCES, 2016, 6 (93): : 90300 - 90304
  • [30] Label-free electrochemical aptasensor for the detection of lysozyme
    Rodriguez, Marcela C.
    Rivas, Gustavo A.
    TALANTA, 2009, 78 (01) : 212 - 216