Dislocations after use of dual-mobility cups in cementless primary total hip arthroplasty: prospective multicentre series

被引:17
|
作者
Hwang, Ji-hyo [1 ]
Kim, Sang-Min [2 ]
Oh, Kwang-Jun [3 ]
Kim, Yeesuk [4 ]
机构
[1] Hallym Univ, Gangnam Sacred Heart Hosp, Sch Med, Dept Orthoped Surg, Seoul, South Korea
[2] Seoul Med Ctr, Dept Orthoped Surg, Seoul, South Korea
[3] KonKuk Univ, Sch Med, Med Ctr, Dept Orthoped Surg, Seoul, South Korea
[4] Hanyang Univ, Sch Med, Dept Orthoped Surg, 222-1 Wangsimni Ro, Seoul, South Korea
关键词
Dislocation; Hip; Dual mobility cup; Total hip arthroplasty; FOLLOW-UP; PREVENT DISLOCATION; FEMORAL-NECK; IN-VITRO; RISK; REPLACEMENT; FRACTURES; SYSTEM; SOCKET; THA;
D O I
10.1007/s00264-017-3660-6
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background The purpose of this study was to investigate the incidence of dislocation and specific complications of the dual-mobility cup. Methods The arthroplasties involved 167 hips in 165 patients; 51 hips (30.5%) were in men and 116 (69.4%) were in women. The active articulation E1 (R) dual-mobility cup (Biomet, Warsaw, IN, USA) was used, and the surgical approach was posterolateral in 120 hips and anterolateral in 47 hips. Results Four (2.3%) dislocations were observed. Mean time of dislocation was 30.5 days post-operatively. Three incomplete reductions occurred during closed reduction. When comparing parameters between dislocation and no-dislocation groups, there were no differences in patient and surgical parameters. However, all dislocations occurred in patients with femoral neck fractures and in the posterolateral approach group. Conclusion The incidence of dislocation in total hip arthroplasty (THA) using a dual-mobility cup was acceptable, and cup diameter of the dislocation group was substantially larger than that of no-dislocation group. Based on clinical outcomes of our study, we conclude that the dual-mobility cup is a reliable option in THA, and further studies are necessary.
引用
收藏
页码:761 / 767
页数:7
相关论文
共 50 条
  • [21] The use of a dual-mobility concept in total hip arthroplasty patients with spastic disordersNo dislocations in a series of ten cases at midterm follow-up
    Rick J. M. Sanders
    Bart A. Swierstra
    Jon H. M. Goosen
    Archives of Orthopaedic and Trauma Surgery, 2013, 133 : 1011 - 1016
  • [22] Ten- to 16-Year Results of a Modern Cementless Dual-Mobility Acetabular Implant in Primary Total Hip Arthroplasty
    Gaillard, Romain
    Kenney, Raymond
    Delalande, Jean-Luc
    Batailler, Cecile
    Lustig, Sebastien
    JOURNAL OF ARTHROPLASTY, 2019, 34 (11): : 2704 - 2710
  • [23] Use of dual mobility cups for revision hip arthroplasty
    Roehner, E.
    Matziolis, G.
    ORTHOPADE, 2017, 46 (02): : 114 - 120
  • [24] Prospective longitudinal study of one hundred patients with total hip arthroplasty using a second-generation cementless dual-mobility cup
    Vermersch, Thibault
    Viste, Anthony
    Desmarchelier, Romain
    Fessy, Michel-Henri
    INTERNATIONAL ORTHOPAEDICS, 2015, 39 (11) : 2097 - 2101
  • [25] Prospective longitudinal study of one hundred patients with total hip arthroplasty using a second-generation cementless dual-mobility cup
    Thibault Vermersch
    Anthony Viste
    Romain Desmarchelier
    Michel-Henri Fessy
    International Orthopaedics, 2015, 39 : 2097 - 2101
  • [26] Dual Mobility Cups as the Routine Choice in Total Hip Arthroplasty
    Aguado-Maestro, Ignacio
    de Blas-Sanz, Ines
    Elena Sanz-Penas, Ana
    Virginia Campesino-Nieto, Silvia
    Diez-Rodriguez, Jesus
    Valle-Lopez, Sergio
    Espinel-Riol, Alberto
    Fernandez-Diez, Diego
    Garcia-Alonso, Manuel
    MEDICINA-LITHUANIA, 2022, 58 (04):
  • [27] Dual mobility cups for total hip arthroplasty: tips and tricks
    Neri, Thomas
    Boyer, Bertrand
    Batailler, Cecile
    Klasan, Antonio
    Lustig, Sebastien
    Philippot, Remi
    Farizon, Frederic
    SICOT-J, 2020, 6
  • [28] The usefulness of dual mobility cups in primary total hip arthroplasty patients at a risk of dislocation
    Nam Hoon Moon
    Min Uk Do
    Jung Shin Kim
    Jae Seung Seo
    Won Chul Shin
    Scientific Reports, 12
  • [29] The usefulness of dual mobility cups in primary total hip arthroplasty patients at a risk of dislocation
    Moon, Nam Hoon
    Do, Min Uk
    Kim, Jung Shin
    Seo, Jae Seung
    Shin, Won Chul
    SCIENTIFIC REPORTS, 2022, 12 (01)
  • [30] Outcomes of dual-mobility acetabular cup for instability in primary and revision total hip arthroplasty
    Mohammed R.
    Hayward K.
    Mulay S.
    Bindi F.
    Wallace M.
    Journal of Orthopaedics and Traumatology, 2015, 16 (1) : 9 - 13